2023-07-20 V. B. #23-009-TRC, Utility Plans, Exhibit 2R/W OR EASEMENT LINE ROAD SURFACE OR OTHER VALVE & VALVE BOX VALVE & VALVE BOX AREA TO BE DRILLED 4 i ,J EXIST. GRADE / 2 MIN.- 1OX PIPE DIA. 2 ADAPTERS /;� OR 4' MIN. MIN HDPE PIPELINE HDPE PIPELINE VALVE ADAPTER 4" MAX SLOPE PERPENDICULAR EXISTING D.I.P. OR P.V.C. PIPELINE CONNECTION STRAIGHT RUN PLAN VIEW CONNECTION MJ SPLIT GASKET MJ FITTING GLAND HDPE PIPE HDPE ADAPTER BUTT FUSION WELD HDPE-MJ ADAPTER NOTES: 1. DIRECTIONAL DRILLS SHALL BE COMPLETED USING DR11 HDPE PIPE, DIP SIZE: FOR WATER AND SANITARY FORCE MAIN IPS SIZE: FOR VACUUM SEWER. 2. ALL DIRECTIONAL DRILLS SHALL BE AT A DEPTH OF 1OX PIPE DIAMETER BELOW THE ROADWAY SURFACE OR 4' WHICHEVER IS GREATER. 3. ALL HDPE MUST BE COLOR CODED (SAFETY BLUE -WATER, SAFETY GREEN FOR SEWER AND PANTONE PURPLE FOR RECLAIMED WATER); BUTT FUSION WELDED; AND CONNECTED WITH HDPE-MJ ADAPTER. 4. 10 GUAGE SOLID COPPER LOCATING WIRES SHALL BE TAPED TO PIPE FROM VALVE TO VALVE AT A SPACING NO GREATER THAN 5 FEET AND PULLED WITH THE PIPE. SEE D17 FOR ADDITIONAL DETAILS. 5. GRAVITY SEWER BORES AS PREAPPROVED BY OUA. OKEECHOBEE UTILITY AUTHORITY CONSTRUCTION STANDARDS & DETAILS REVISION PAGE No OCT. 2015 DIRECTIONAL DRILLING DETAIL D19 CHLORINATION & PRESSURE INJECTION POINT METER, RP BACKFLOW & ISOLATION VALVES EXISTING WATER MAIN CONTRACTOR GAUGE OUA GAUGE 1. WATER MAIN TO BE PRESSURE TESTED AND DISINFECTED ACCORDING TO FDEP REGULATIONS, AWWA STANDARDS AND OUA REQUIREMENTS. 2. BACTERIOLOGICAL TESTING IS TO BE PERFORMED BY CONTRACTOR WITH PRIOR NOTIFCATION OF TESTING TO OUA PERSONNEL. 3. DO NOT REMOVE TEMPORARY CONNECTION UNTIL ALL TESTING HAS BEEN COMPLETED. 4. PROVIDE ALL NECESSARY THRUST BLOCKS OR OTHER RESTRAINTS. 5. FILLING AND FLUSHING LOCATIONS SHALL BE DETERMINED BY THE CONTRACTOR AND WITH APPROVAL OF ENGINEER AND/OR OUA. 6. MAIN LINE VALVE TO BE OPENED BY OUA PERSONNEL ONLY AND OPENED FOR CANNON FLUSHING OF NEW PIPING SYSTEM. PLAN CAST IRON COVER MARKED "WATER", "SEWER" OR "FIRI TOP OF PAVEMENT --\ 5-1/4" C.I. ADJUSTABLE VALVE BOX (INSIDE SCREW TYPE) D/I OR C-900 P.V.C. SQUARE NUT MECHANICAL JOINT VALVE ASPHALTIC CONCRETE OVERLAY AREA SEE DRAWINGS FOR LIMITS SURFACE REPLACEMENT L W+4' TOP OF TRENCH CONCRETE COLLAR 6" IN WIDTH / POUR CONCRETE COLLAR TO GRADE IN SODDED AREAS CONCRETE BRICKS FOR PADS NOTE, 'A -- VALVE NUT EXTENSION IS REQUIRED ON ALL VALVES WITH MORE THAN 36" OF COVER. EXTEND NUT TO WITHIN 18" OF VALVE BOX RIM. PROVIDE SOLID BRICK PAD FOR VALVE BOX TO SIT ON. NOTES: EXISTING ASPHALT SURFACE BACKFILL TRENCH WITH FLOWABLE FILL UP TO WITHIN 2" OF EXISTING ASPHALT SURFACE 1AX I BENSITY ET & COMPACTED TI 9M MAX. AAX. DENSITY AT +/- 29. OF OPTIMUM MOISTURE AS DETERMINED BY MODIFIED PROCTOR TEST AASHTO T-180/ASTM D 1557, IN 6" LOOSE THICKNESS LIFTS. EARTH 1. BACKFILL MATERIALS AROUND AND UP TO 1 FOOT ABOVE PIPE SHALL CONSIST OF CLEAN EARTH FILL COMPRISED OF SAND, SAND AND CLAY, GRAVEL, CRUSHED ROCK OR OTHER MATERIALS FROM GROUPS A-1, A-2 OR A-3 AASHTO CLASSIFICATION FREE FROM ORGANIC MATTER AND VEGETATION, DEBRIS, LARGE CLODS OR EARTH OR STONES. UNSUITABLE IN -SITU MATERIALS SUCH AS MUCK, DEBRIS, LARGE ROCK AND ROOTS SHALL BE REMOVED AND DISPOSED OF BY THE CONTRACTOR. 2. FLOWABLE FILL FROM A POINT 12" ABOVE TOP OF PIPE TO 2" BELOW EXISTING ASPHALT SURFACE, SHALL BE READY -MIXED FLOWABLE FILL CONSISTING OF PORTLAND CEMENT, AGGREGATES, WATER AND MINERAL MIXTURES IN COMPLIANCE WITH F.D.O.T. STANDARD SPECIFICATIONS, SECTION 121. 3. THE PIPE SHALL BE FULLY SUPPORTED ALONG ENTIRE LENGTH. 4. THE PIPE TRENCH SHALL REMAIN DRY DURING PIPE LAYING OPERATIONS. 5. ALL TRENCH WORK SHALL CONFORM TO LATEST STANDARDS AS SET FORTH BY THE FLORIDA TRENCH SAFETY ACT AND OR OSHA. 6. FOUR INCH WIDE DETECTABLE TAPE SHALL BE PLACED APPROXIMATELY 12"-18" BELOW FINISHED GRADE AND DIRECTLY ABOVE ALL PRESSURE PIPING. TAPE, WORDING AND COLOR SHALL CONFORM TO O.U.A. STANDARDS. 7. SURFACE COURSE SHALL BE F.D.O.T. MIX, TO MATCH EXISTING PAVEMENT, WITH A THICKNESS EQUAL TO THE EXISTING OR 2", WHICHEVER IS GREATER. 8. PAVEMENT JOINTS SHALL BE MECHANICALLY SAWED BUTT JOINTS, HEATED, RAKED AND SPRAYED WITH A REJUVENATING AGENT. THE PATCH AREA SHALL BE A SMOOTH PLANE SUCH THAT A STRAIGHT EDGE PLACED ACROSS THE PATCH, PARALLEL TO THE TRAFFIC FLOW AND EXTENDING TO UNDISTURBED PAVEMENT SHALL SHOW NO MORE THAN 1/4" IRREGULARITY IN ANY 15 FT. SECTION. ANY IRREGULARITY SHALL BE CORRECTED IN ACCORDANCE WITH F.D.O.T. SPECIFICATIONS. 9. "COLD PATCH" SHALL BE USED FOR TEMPORARY REPAIRS ONLY, AND FOR A PERIOD NOT TO EXCEED 30 DAYS. 10. TRAFFIC LANE CLOSURES, MOT PLANS AND ROADWAY REPAIRS MATERIALS SHALL BE PER DIRECTION OF ROAD OWNER. CONTRACTOR TO INQUIRE WITH OWNER ABOUT REQUIREMENTS PRIOR TO BID. 11. 3M LOCATOR BALLS SHALL BE INSTALLED AT EACH FITTING IN THE PIPE LINE CHANGING DIRECTION AND AT EACH CONNECTION. 12. 3M LOCATORS TO BE PROVIDED BY DEVELOPER AS SPECIFIED BY O.U.A. PAVEMENT C.I. COVER (FOR PAVED AREA) / - CONCRETE VALVE PAD � /� FINISHED GRADE (FOR /�\•(\ NON -PAVED AREA) COMPACTED EARTH CAST IRON, ROADWAY TYPE, EXTENSION VALVE BOX (INSIDE SCREW) 3" PVC W/THREADED PVC INVERTED KEY PLUG (FLUSH) TWO (2) PAIRS OF INSULATED METALLIC 10 GAUGE SOLID COPPER WIRE (TYP.) EACH PAIR 7 HEADING ON OPPOSITE DIRECTIONS / PRESSURE MAIN DUCT TAPE (5 PER PIPE LENGTH) 1. ALL PVC PIPE SHALL REQUIRE TWO PAIRS OF INSULATED METALUC LOCATING HIRES (10 GAUGE SOLID COPPER) TAPED NTH 2" WIDE DUCT TAPE TO TOP CENTERLINE OF THE PIPE AT EVERY JOINT AND AT 4 ADDITIONAL EQUALLY SPACED POINTS PER LENGTH OF PIPE. 2. LOCATING WIRES TO TERMINATE ON EACH END AT A VALVE BOX, 4" ABOVE GROUND AND FOLDED BACK INSIDE VALVE BOX. 3. LOCATING WIRES SHALL BE CAPABLE OF DETECTION BY A CABLE LOCATOR AND PASS A FIELD CONDUCTIVITY TEST, OBSERVED BY THE O.U.A., FROM END TO END OF WIRES. 4. SPLICES SHALL BE CAPABLE OF COMPLETE SUBMERSION, SUCH AS BUTT SPLICE WITH RAYCHEM HEAT SHRINK TUBING. 5. NO MORE THAN ONE SPLICE IN LOCATING HARES BETWEEN VALVES IS ALLOWED. 6. PROVIDE POTTING COMPOUND AT TRACER HARE JUNCTIONS AND SPLICES. 7. THE ENDS OF ALL LOCATING HARES, WHETHER THEY ARE SPLICED, CONNECTED, OR TERMINATED, SHALL HAVE THE LAST THREE INCHES PIG TAILED AS DETAILED HEREON. 4" WARNING TAPE METALLIC LOCATING WIRE FINISHED GRADE 18 MAXIMUM 1" MAX PVC PRESSURE MAIN PVC PIPE LOCATING WIRE PIG TAIL WIRE AFTER PASSING THROUGH #10 THIN LOCATING SPLIT BOLT WIRE (SOLID COPPER HARE KITH BLUEYMIN.1 4" MIN. COATING) 1/4" X 3/4" SPLIT BOLT LOCATING WIRE DETAIL OKEECHOBEE UTILITY AUTHORITY CONSTRUCTION STANDARDS & DETAILS OKEECHOBEE UTILITY AUTHORITY CONSTRUCTION STANDARDS & DETAILS OKEECHOBEE UTILITY AUTHORITY CONSTRUCTION STANDARDS & DETAILS OKEECHOBEE UTILITY AUTHORITY CONSTRUCTION STANDARDS & DETAILS REVISION PAGE No REVISION PAGE No REVISION TRENCH REPAIR DETAILS PAGE No REVISION LOCATING WIRE DETAILS PAGE No OCT. 2015 FILLING, DISINFECTING AND TESTING DETAILS D10 OCT. 2015 TYPICAL VALVE SETTING D12 OCT. 2015 PAVED AREAS WITH FLOWABLE FILL BACKFILL D13B OCT. 2015 FOR ALL ROAD CROSSINGS AND BORES D17