Loading...
2023-05-18 V. A. 23-001-TRC Drawings dated 03/24/23SHEET INDEX: SHEET C000: TITLE SHEET SHEET C001: GENERAL NOTES & SPECIFICATIONS SHEET CD001: BLOCK 110 EXISTING CONDITION, DEMOLITION,AND SEDIMENT CONTROL PLAN SHEET CDO02: BLOCK 121 EXISTING CONDITION, DEMOLITION,AND SEDIMENT CONTROL PLAN SHEET C201: BLOCK 110 HORIZONTAL CONTROL, STRIPPING AND SIGNAGE PLAN SHEET C202: BLOCK 121 HORIZONTAL CONTROL, STRIPPING AND SIGNAGE PLAN SHEET C301: BLOCK 110 PAVING, GRADING & DRAINAGE PLAN SHEET C302: BLOCK 121 PAVING, GRADING & DRAINAGE PLAN SHEET C401: BLOCK 110 OVERALL SEWERLINE PLAN SHEET C402: BLOCK 121 OVERALL SEWERLINE PLAN SHEET C501: BLOCK 110 OVERALL WATERLINE PLAN SHEET C502: BLOCK 121 OVERALL WATERLINE PLAN SHEET C600: DETAILS — 1 SHEET C601: DETAILS — 2 SHEET C602: DETAILS 3 SHEET C603: DETAILS — 4 SHEET C604: DETAILS — 5 SHEET C701: BLOCK 110 LANDSCAPING PLAN SHEET C702: BLOCK 121 LANDSCAPING PLAN MINOR SUBDIVISION G L E vOD PARK LOCATED IN SECTION 15, TOWNSHIP 37 SOUTH, RANGE 35 EAST OKEECHOBEE CITY, FLORIDA CALL 48 HOURS BEFORE YOU DIG IN FLORIDA, IT'S THE LAW r , Ir of Florida, Inc. GRAPHIC SCALE 60 0 30 60 120 240 ( IN FEET ) 1 inch = 60 ft. 7 x - M 0` n b Aai — SITE m NW 91h St O Cypress , o NW Sth St Quarters NW 7th St NW Ah St NW 7th St NW 6th St z _ , NW Sih S1 NW3th St /! NW Ash St ` a NW 4th st a NE 41h St �`. NW 3rd St 3 D NW 3rd s1 n _ NW ttasl Park St 8 _ 7o O NW NW 20d St _Okeechobee-_ park St--, - - ® (:solar Sl q T c n w � n SE Ath St n sw 6th St SE 6th St _. SW Bth St a' SW eth st K =/ 4* 'St :!t SW 16th S1 SW 161h St ti o WalmartSupercenterQyMsE2smor SE 27th St y n SW 261h St Ao19 R-' l:J SE 23th St JII f SE y 2 Y n 32nd St I:�a.�yn��nrar��naarzy,.,in�mre� LOCATION MAP N.T.S. VICINITY MAP N.T.S. LEGAL DESCRIPTION LOT 1 THROUGH 12, INCLUSIVELY, BLOCK 110, CITY OF OKEECHOBEE, PLAT BOOK 5, PAGE 5, OKEECHOBEE COUNTY, FLORIDA. LOT 1 THROUGH 12, INCLUSIVELY, BLOCK 121, CITY OF OKEECHOBEE, PLAT BOOK 5, PAGE 5, OKEECHOBEE COUNTY, FLORIDA. GENERAL NOTES BEACH PIERCE )RT ST. LUCIE TUART JUPITER WEST PALM B 1. THE SURVEY DATE IS MARCH 18, 2021. 2. THIS IS A BOUNDARY SURVEY, AS DEFINED IN CHAPTER 5J-17.050(11) OF THE FLORIDA ADMINISTRATIVE CODE. 3, THIS SURVEY MAP AND REPORT OR THE COPIES THEREOF ARE NOT VALID WITHOUT THE SIGNATURE AND THE ORIGINAL SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER. 4. ADDITIONS OR DELETIONS TO SURVEY MAPS OR REPORTS BY OTHER THAN THE SIGNING PARTY OR PARTIES IS PROHIBITED WITHOUT WRITTEN CONSENT OF THE SIGNING PARTY OR PARTIES. 5. BEARINGS SHOWN HEREON ARE BASED ON GRID NORTH, AND ARE REFERENCED TO THE FLORIDA STATE PLANE COORDINATE SYSTEM, EAST ZONE, NORTH AMERICAN DATUM OF 1983, 2011 ADJUSTMENT, THE BEARING BASE FOR THIS SURVEY IS THE CENTERLINE OF NORTHEAST 4TH STREET BETWEEN BLOCKS 110 AND 121, SAID LINE BEARS N 89°47'50" E AND ALL OTHER BEARINGS ARE RELATIVE THERETO. 6. THIS SURVEY DOES NOT HAVE THE BENEFIT OF A CURRENT TITLE COMMITMENT, OPINION, OR ABSTRACT. DURING THE COURSE OF THE SURVEY SOME SEARCHES OF THE PUBLIC RECORDS WERE MADE, BUT THESE SEARCHES WERE NOT EXHAUSTIVE AND SHOULD NOT BE CONSIDERED A SUBSTITUTE FOR A PROPER TITLE COMMITMENT, OPINION, OR ABSTRACT OBTAINED FROM A TITLE AGENCY OR OTHER TITLE PROFESSIONAL. 7. THE LEGAL DESCRIPTION OF THE LAND CONTAINED IN THIS BOUNDARY SURVEY IS BASED ON THE DESCRIPTION RECORDED IN OFFICIAL RECORDS BOOK 786, PAGE 1593, AND OFFICIAL RECORDS BOOK 816, PAGE 970 AS RECORDED IN THE PUBLIC RECORDS OF OKEECHOBEE COUNTY, FLORIDA. -? THIS SURVEY DELINEATES THE LOCATIONS OF THE LEGAL DESCRIPTIONS ON THE GROUND, BUT DOES NOT DETERMINE OWNERSHIP OR PROPERTY RIGHTS. 9. ADJOINING PROPERTY INFORMATION WAS OBTAINED FROM OKEECHOBEE COUNTY PROPERTY APPRAISER OFFICE AND PER PLAT. 10. AERIAL IMAGERY SHOWN HEREON WAS OBTAINED FROM THE LAND BOUNDARY INFORMATION SYSTEM (LABINS) DATED 2018 AND IS SHOWN FOR INFORMATIONAL PURPOSES ONLY. 11. SUBJECT PROPERTY IS LOCATED IN FLOOD ZONE X PER FEMA MAP NUMBER 12093C, PANEL NUMBER 0485C, WITH AN EFFECTIVE DATE OF 07/16/15. INDIO H GENERAL NOTES EROSION AND SEDIMENTATION CONTROL NOTES - (CONTINUED) CONTINUED: N I N N I 1. CONTRACTOR IS RESPONSIBLE FOR CHECKING ACTUAL SITE CONDITIONS BEFORE STARTING CONSTRUCTION. 2. ANY DISCREPANCIES ON THE DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER BEFORE COMMENCING WORK. 3. CONTRACTOR SHALL OBTAIN ALL REQUIRED BUILDING PERMITS BEFORE COMMENCING WORK. 4. CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATION OF ALL EXISTING UTILITIES. THE CONTRACTOR SHALL CONTACT ALL CONCERNED UTILITIES AT LEAST 48 HOURS IN ADVANCE FOR CONSTRUCTION OPERATIONS. 5. NO FIELD CHANGES OR DEVIATIONS FROM DESIGN TO BE MADE WITHOUT PRIOR APPROVAL OF THE ENGINEER. 6. ALL CONSTRUCTION SHALL BE COMPLETED IN ACCORDANCE WITH THE APPLICABLE ORDINANCES OF CITY OF OKEECHOBEE, FLORIDA. 7. CONTRACTOR SHALL SUPPLY DENSITY TESTS TO ENGINEER ON ALL SUB -GRADE AND BASE. TESTS SHALL BE PREPARED PER AASHTO T-180 METHOD. 8. SLOPE GRADES FROM ELEVATIONS SHOWN TO EXISTING GRADE AT PROPERTY LINE. 9. ENGINEER SHALL BE NOTIFIED AT LEAST 48 HOURS IN ADVANCE FOR ANY INSPECTION. 10. ALL TRAFFIC CONTROL DEVICES SHALL BE IN ACCORDANCE WITH M.U.T.C.D. STANDARDS. 11. EROSION AND SEDIMENTATION CONTROL TECHNIQUES SHALL BE INCORPORATED DURING CONSTRUCTION AS FOLLOWS: (1) SILT SCREENS SHALL BE MAINTAINED AT THE PROJECT PERIMETER. (2) NO OFF -SITE DISCHARGES SHALL OCCUR DURING CONSTRUCTION. IN THE EVENT DISCHARGE IS REQUIRED, HAY BALES AND/OR TURBIDITY CURTAINS SHALL BE INCORPORATED AT THE DISCHARGE POINT AS NECESSARY TO CONTROL TURBIDITY. EROSION AND SEDIMENTATION CONTROL NOTES CONSTRUCTION ACTIVITIES CAN RESULT IN THE GENERATION OF SIGNIFICANT AMOUNTS OF POLLUTANTS WHICH MAY REACH SURFACE OR GROUND WATERS. ONE OF THE PRIMARY POLLUTANTS OF SURFACE WATERS IS SEDIMENT DUE TO EROSION. EXCESSIVE QUANTITIES OF SEDIMENT WHICH REACH WATER BODIES OF FLOODPLAINS HAVE BEEN SHOWN TO ADVERSELY AFFECT THEIR PHYSICAL, BIOLOGICAL AND CHEMICAL PROPERTIES. TRANSPORTED SEDIMENT CAN OBSTRUCT STREAM CHANNELS, REDUCE HYDRAULIC CAPACITY OF WATER BODIES OF FLOODPLAINS, REDUCE THE DESIGN CAPACITY OF CULVERTS AND OTHER WORKS, AND ELIMINATE ETHIC INVERTEBRATES AND FISH SPAWNING SUBSTRATES BY SILTATION. EXCESSIVE SUSPENDED SEDIMENTS REDUCE LIGHT PENETRATION AND THEREFORE, REDUCE PRIMARY PRODUCTIVITY. MINIMUM STANDARDS: 1. SEDIMENT BASIN AND TRAPS, PERIMETER DIKES, SEDIMENT BARRIERS AND OTHER MEASURES INTENDED TO TRAP SEDIMENT SHALL BE CONSTRUCTED AS A FIRST STEP IN ANY LAND -DISTRIBUTING ACTIVITY AND SHALL BE MADE FUNCTIONAL BEFORE UNSLOPE LAND DISTURBANCE TAKES PLACE. 2. ALL SEDIMENT CONTROL MEASURES ARE TO BE ADJUSTED TO MEET FIELD CONDITIONS AT THE TIME OF CONSTRUCTION AND BE CONSTRUCTED PRIOR TO ANY GRADING OR DISTURBANCE OF EXISTING SURFACE MATERIAL ON BALANCE OF SITE. PERIMETER SEDIMENT BARRIERS SHALL BE CONSTRUCTED TO PREVENT SEDIMENT OR TRASH FROM FLOWING OR FLOATING ON TO ADJACENT PROPERTIES. 3. PERMANENT OR TEMPORARY SOIL STABILIZATION SHALL BE APPLIED TO DENUDED AREAS WITHIN SEVEN DAYS AFTER FINAL GRADE IS REACHED ON ANY PORTION OF THE SITE. TEMPORARY SOIL STABILIZATION SHALL BE APPLIED WITHIN SEVEN DAYS TO DENUDED AREAS THAT MAY NOT BE AT FINAL GRADE BUT WILL REMAIN UNDISTURBED FOR LONGER THAN 30 DAYS. PERMANENT STABILIZATION SHALL BE APPLIED TO AREAS THAT ARE TO BE LEFT UNDISTURBED FOR MORE THAN ONE YEAR. 4. DURING CONSTRUCTION OF THE PROJECT, SOIL STOCKPILES SHALL BE STABILIZED OR PROTECTED WITH SEDIMENT TRAPPING MEASURES. THE APPLICANT IS RESPONSIBLE FOR THE TEMPORARY PROTECTION AND PERMANENT STABILIZATION OF ALL SOIL STOCKPILES ON SITE AS WELL AS SOIL INTENTIONALLY TRANSPORTED FROM THE PROJECT SITE. 5. A PERMANENT VEGETATIVE COVER SHALL BE ESTABLISHED ON DENUDED AREAS NOT OTHERWISE PERMANENTLY STABILIZED. PERMANENT VEGETATION SHALL NOT BE CONSIDERED ESTABLISHED UNTIL A GROUND COVER IS ACHIEVED THAT, IN THE OPINION OF THE REVIEWER, IS UNIFORM, MATURE ENOUGH TO SURVIVE AND WILL INHIBIT EROSION. 6. STABILIZATION MEASURES SHALL BE APPLIED TO EARTHEN STRUCTURES SUCH AS DAMS, DIKES AND DIVERSIONS IMMEDIATELY AFTER INSTALLATION. 7. SURFACE RUNOFF FROM DISTURBED AREAS THAT IS COMPRISED OF FLOW FROM DRAINAGE AREAS GREATER THAN OR EQUAL TO THREE ACRES SHALL BE CONTROLLED BY A SEDIMENT BASIN. THE SEDIMENT BASIN SHALL BE DESIGNED AND CONSTRUCTED TO ACCOMMODATE THE ANTICIPATED SEDIMENT LOADING FROM THE LAND -DISTURBING ACTIVITY. THE OUTFALL DEVICE OR SYSTEM DESIGN SHALL TAKE INTO ACCOUNT THE TOTAL DRAINAGE AREA FLOWING THROUGH THE DISTURBED AREA TO BE SERVED BY THE BASIN. 8. AFTER ANY SIGNIFICANT RAINFALL, SEDIMENT CONTROL STRUCTURES WILL BE INSPECTED FOR INTEGRITY. ANY DAMAGED DEVICES SHALL BE CORRECTED IMMEDIATELY. 9. CONCENTRATED RUNOFF SHALL NOT FLOW DOWN CUT OR FILL SLOPES UNLESS CONTAINED WITHIN AN ADEQUATE TEMPORARY OR PERMANENT CHANNEL, FLUME OR SLOPE DRAIN STRUCTURE. 10. WHENEVER WATER SEEPS FROM A SLOPE FACE, ADEQUATE DRAINAGE OR OTHER PROTECTION SHALL BE PROVIDED. 11. SEDIMENT WILL BE PREVENTED FROM ENTERING ANY STORM DRAIN SYSTEM, DITCH OR CHANNEL. ALL STORM SEWER INLETS THAT ARE MADE OPERABLE DURING CONSTRUCTION SHALL BE PROTECTED SO THAT SEDIMENT -LADEN WATER CANNOT ENTER THE CONVEYANCE SYSTEM WITHOUT FIRST BEING FILTERED OR OTHERWISE TREATED TO REMOVE SEDIMENT. 12. BEFORE TEMPORARY OR NEWLY CONSTRUCTED STORMWATER CONVEYANCE CHANNELS ARE MADE OPERATIONAL, ADEQUATE OUTLET PROTECTION AND ANY REQUIRED TEMPORARY OR PERMANENT CHANNEL LINING SHALL BE INSTALLED IN BOTH THE CONVEYANCE CHANNEL AND RECEIVING CHANNEL. 13. WHEN WORK IN A LIVE WATERCOURSE IS PERFORMED, PRECAUTIONS SHALL BE TAKEN TO MINIMIZE ENCROACHMENT, CONTROL SEDIMENT TRANSPORT AND STABILIZE THE WORK AREA TO THE GREATEST EXTENT POSSIBLE DURING CONSTRUCTION. NONERODIBLE MATERIAL SHALL BE USED FOR THE CONSTRUCTION OF CAUSEWAYS AND COFFERDAMS. EARTHEN FILL MAY BE USED FOR THESE STRUCTURES IF ARMORED BY NONERODIBLE COVER MATERIALS. 14. WHEN A LIVE WATERCOURSE MUST BE CROSSED BY CONSTRUCTION VEHICLES, A TEMPORARY STREAM CROSSING CONSTRUCTED OF NONERODIBLE MATERIAL SHALL BE PROVIDED. 15. THE BED AND BANKS OF A WATERCOURSE SHALL BE STABILIZED IMMEDIATELY AFTER WORK IN THE WATERCOURSE IS COMPLETED. 16. PERIODIC INSPECTION AND MAINTENANCE OF ALL SEDIMENT CONTROL STRUCTURES MUST BE PROVIDED TO ENSURE INTENDED PURPOSE IS ACCOMPLISHED. THE DEVELOPER, OWNER AND/OR CONTRACTOR SHALL BE CONTINUALLY RESPONSIBLE FOR ALL SEDIMENT LEAVING THE PROPERTY. SEDIMENT CONTROL MEASURES SHALL BE IN WORKING CONDITION AT THE END OF EACH WORKING DAY. 17. UNDERGROUND UTILITY LINES SHALL BE INSTALLED IN ACCORDANCE WITH THE FOLLOWING STANDARDS IN ADDITION TO OTHER APPLICABLE CRITERIA: A. NO MORE THAN 500 LINEAR FEET OF TRENCH MAY BE OPENED AT ONE TIME. B. EXCAVATED MATERIAL SHALL BE PLACED ON THE UPHILL SIDE OF TRENCHES. C. EFFLUENT FROM DEWATERING OPERATIONS SHALL BE FILTERED OR PASSED THROUGH AN APPROVED SEDIMENT TRAPPING DEVICE, OR BOTH, AND DISCHARGED IN A MANNER THAT DOES NOT ADVERSELY AFFECT FLOWING STREAMS OR OFF -SITE PROPERTY. D. RESTABILIZATION SHALL BE ACCOMPLISHED IN ACCORDANCE WITH THESE REGULATIONS. ENGINEER OF RECORD INSPECTION REQUIREMENTS F.B.V. DENSITY L.B.R. THICKNESS MAX. SPACING MAX. SPACING MAX. SPACING MAX. SPACING LINEAR SQUARE LINEAR SQUARE LINEAR SQUARE LINEAR SQUARE FEET FEET FEET FEET FEET FEET FEET FEET COMPACTED OR STABILIZED GRADE 200 5,000 200 5,000 200 5,000 300 10,000 ROCK BASE ---- ---- 300 10,000 300 10,000 300 10,000 SHELL ROCK ---- ---- 300 10,000 ---- ---- 300 10,000 ASPHALT ---- ---- ---- ---- --- PER PER INSP. I INSP. ALL TESTING SHALL BE TAKEN IN A STAGGERED SAMPLING PATTERN FROM A POINT 121, INSIDE THE LEFT EDGE OF THE ITEM TESTED, TO THE CENTER, TO A POINT INSIDE OF THE RIGHT EDGE 18. WHERE CONSTRUCTION VEHICLE ACCESS ROUTES INTERSECT PAVED PUBLIC ROADS, PROVISIONS SHALL BE MADE TO MINIMIZE THE THE CONTRACTOR SHALL COMPLY WITH CHAPTER 90-96, LAWS OF FLORIDA, WHICH REQUIRES THE CONTRACTOR PERFORMING TRENCH TRANSPORT OF SEDIMENT BY TRACKING ONTO THE PAVED SURFACE, WHERE SEDIMENT IS TRANSPORTED ONTO A PUBLIC ROAD SURFACE EXCAVATIONS OVER FIVE FEET IN DEPTH COMPLY WITH ALL APPLICABLE TRENCH SAFETY STANDARDS AND SHORING REQUIREMENTS AS WITH CURBS AND GUTTERS, THE ROAD SHALL BE CLEANED THOROUGHLY AT THE END OF EACH DAY. SEDIMENT SHALL BE REMOVED SET FORTH IN THE OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION'S (OSHA) EXCAVATION AND SAFETY STANDARDS, 29 C.F.R. FROM THE ROADS BY SHOVELING OR SWEEPING AND TRANSPORTED TO A SEDIMENT CONTROL DISPOSAL AREA. STREET WASHING SHALL 19926.650, SUB -PART P AND INCORPORATED AS THE STATE OF FLORIDA STANDARD, AS REVISED AND/OR UPDATED. THE COST OF BE ALLOWED ONLY AFTER SEDIMENT IS REMOVED IN THIS MANNER. THIS PROVISION SHALL APPLY TO INDIVIDUAL SUBDIVISION LOTS AS COMPLIANCE WITH THIS REQUIREMENT SHALL BE INCLUDED AS A SEPARATE LINE ITEM ON THE CONTRACTOR'S BID. OTHERWISE, WELL AS TO LARGER LAND- DISTRIBUTING ACTIVITIES. CONTRACTOR CERTIFIES THAT THE COST OF COMPLIANCE IS INCLUDED IN THE UNIT COST OF ALL ITEMS OF WORK TO WHICH THIS REQUIREMENT APPLIES. 19. ALL TEMPORARY EROSION AND SEDIMENT CONTROL MEASURES SHALL BE REMOVED WITHIN 30 DAYS AFTER FINAL SITE STABILIZATION OR AFTER THE TEMPORARY MEASURES ARE NO LONGER NEEDED, IN THE OPINION OF THE REVIEWER. DISTURBED SOIL AREAS RESULTING FROM THE DISPOSITION OF TEMPORARY MEASURES SHALL BE PERMANENTLY STABILIZED TO PREVENT FURTHER EROSION AND SEDIMENTATION. 20. PROPERTIES AND WATERWAYS DOWNSTREAM FROM CONSTRUCTION SITE SHALL BE PROTECTED FROM SEDIMENT DISPOSITION AND EROSION. ■ ,:I_G9■ 1•,CZ■111=■lG' .`P.[0lll■ 1•.l=■]■7_1.»Il•II<K■]R M@a[a1■IRVi91P.<KNaU`I1[NIt■]i7_Z■l:■,:I_G9M 22. EROSION CONTROL DESIGN AND CONSTRUCTION SHALL FOLLOW THE REQUIREMENTS IN INDEX NOS. 101, 102 AND 103 OF FDOT ROADWAY AND TRAFFIC DESIGN STANDARDS. 23. THE REVIEWER MAY APPROVE MODIFICATIONS OR ALTER PLANS TO THESE EROSION CONTROL CRITERIA DUE TO SITE SPECIFIC CONDITIONS. EARTHWORK AND DRAINAGE SPECIFICATION 1 . CLEARING AND GRUBBING: CLEARING AND GRUBBING SHALL BE PERFORMED WITHIN THE LIMITS OF THE PROJECT WORK IN ACCORDANCE WITH SECTION 110, FLORIDA DEPARTMENT OF TRANSPORTATION (FDOT) SPECIFICATIONS. THIS ITEM SHALL INCLUDE, BUT IS NOT LIMITED TO, THE COMPLETE REMOVAL AND LEGAL DISPOSAL OF ALL TREES, BRUSH, STUMPS, ROOTS, GRASS, WEEDS, RUBBISH AND OTHER UNDESIRABLE MATERIAL TO A DEPTH OF 18 INCHES BELOW NATURAL GROUND OR PROPOSED FINISHED GRADE, WHICHEVER IS LOWER. THE AREAS TO BE CLEARED GENERALLY CONSIST OF THE ENTIRE SITE WITH THE EXCEPTION OF AREAS SPECIFICALLY NOTED ON THE LANDSCAPE PLANS AS PRESERVE AREAS OR AS AREAS TO REMAIN UN -CLEARED. CARE SHALL BE TAKEN TO INSURE THAT NO PRESERVE AREAS OR WETLAND AREAS ARE IMPACTED BY THE CLEARING OPERATION. PRIOR TO INITIATING THE CLEARING OPERATION, ALL ADJACENT WETLAND AND PRESERVE AREAS SHALL BE MARKED AND FLAGGED IN ACCORDANCE WITH THE CITY OF OKEECHOBEE AND SOUTH FLORIDA WATER MANAGEMENT DISTRICT (SFWMD) REQUIREMENTS ALL SUCH AREAS IMMEDIATELY ADJACENT TO THE CLEARING OPERATION SHALL ALSO BE PROTECTED BY THE INSTALLATION OF TEMPORARY SILT BARRIERS IN ACCORDANCE WITH THE REQUIREMENTS OF THE CITY OF OKEECHOBEE AND THE SFWMD. FURTHER EROSION CONTROL SHALL BE ACCOMPLISHED BY SEEDING AND MULCHING ALL DISTURBED AREAS AS SOON AS THEY ARE AT FINAL GRADE, PER THE SPECIFICATIONS FOR SEEDING AND MULCHING FOUND ELSEWHERE ON THIS SHEET. ALL MATERIAL SHALL BE REMOVED FROM THE SITE AND SHALL BE LEGALLY DISPOSED OF IN ACCORDANCE WITH ALL LOCAL, STATE AND FEDERAL REQUIREMENTS. 2.EARTHWORK AND GRADING: ALL EARTHWORK AND GRADING SHALL BE PERFORMED AS REQUIRED TO ACHIEVE THE FINAL GRADES, TYPICAL SECTIONS AND ELEVATIONS SHOWN ON THE PLANS. IN ALL OTHER RESPECTS, MATERIALS AND CONSTRUCTION METHODS FOR EARTHWORK, EMBANKMENT, EXCAVATION AND GRADING SHALL CONFORM TO THE REQUIREMENTS OF FDOT SPECIFICATIONS, SECTION 120. ANY PLASTIC OR OTHERWISE UNDESIRABLE MATERIAL WITHIN 36 INCHES OF FINISHED ROAD GRADE SHALL BE REMOVED AND REPLACED WITH SUITABLE MATERIAL. THE CONTRACTOR SHALL ALSO REFER TO THE SOILS REPORT, IF AVAILABLE. THE SPECIFICATIONS AND RECOMMENDATIONS INCLUDED IN THAT REPORT SHALL BE CONSIDERED AS A PART OF THESE PLANS AND SPECIFICATIONS. SHOULD THERE BE ANY CONFLICT BETWEEN THAT DOCUMENT AND ANY REQUIREMENTS OF THESE DRAWINGS OR SPECIFICATIONS, THE MOST RESTRICTIVE REQUIREMENT SHALL GOVERN. C1!lau►[e>■IINA=91•/0a0111611 ALL AREAS PROPOSED FOR PAVING SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE DESIGN GRADES AND TYPICAL SECTIONS SHOWN ON THE DRAWINGS, AND IN CONFORMANCE TO THE REQUIREMENTS OF THE CITY OF OKEECHOBEE AND FLORIDA DEPARTMENT OF TRANSPORTATION. A. ASPHALT: PRIME COAT AND TACK COAT FOR BASE COURSE AND BETWEEN LIFTS OF ASPHALT SHALL CONFORM TO THE REQUIREMENTS OF SECTIONS 300-1 THROUGH 300-7 OF THE FDOT SPECIFICATIONS. PRIME COAT SHALL BE APPLIED AT A RATE OF 0.25 GALLONS PER SQUARE YARD AND TACK COAT AT A RATE OF 0.10 GALLONS PER SQUARE YARD, UNLESS OTHERWISE APPROVED BY THE ENGINEER. ASPHALT SURFACE COURSE THICKNESS AND MATERIAL SHALL BE AS SHOWN ON THE TYPICAL SECTIONS AND SHALL IN ALL WAYS CONFORM TO THE REQUIREMENTS OF FDOT. B. BASE: LIMEROCK BASE MATERIAL SHALL BE COMPACTED TO 98% OF MAXIMUM DENSITY PER AASHTO T-180. ALL LIMEROCK SHALL MEET THE MINIMUM REQUIREMENTS OF FDOT SECTION 911. AS AN ALTERNATE, CEMENTED COQUINA CONFORMING TO FDOT SECTION 915 MAY BE SUBSTITUTED AND SHALL BE SUBJECT TO THE COMPACTION SPECIFICATIONS DETAILED ABOVE AND INCLUDED IN THE SOILS ENGINEER'S REPORT. C. SUB -GRADE: SUB -GRADE SHALL BE COMPACTED TO 98% OF MAXIMUM DENSITY PER AASHTO T-180, AND STABILIZED TO A MINIMUM FBV OF 50PS1. SUB -GRADE SHALL BE THOROUGHLY ROLLED WITH A PNEUMATIC TIRED ROLLER PRIOR TO SCHEDULING ANY SUB -GRADE INSPECTION. D. VALLEY GUTTER/ F-CURB/D-CURB/FLUSH CURB: SHALL BE CONSTRUCTED PER THE TYPICAL SECTION BY EXTRUDING MACHINE OR FORMS AS SHOWN ON THE PLANS. MINIMUM CONCRETE COMPRESSIVE STRENGTH SHALL BE 3,000PSI AFTER 28 DAYS. SUB -GRADE SHALL BE MOISTENED AT THE TIME CONCRETE IS PLACED TO INSURE A UNIFORMLY DAMP SURFACE. READY -MIX CONCRETE SHALL HAVE A SLUMP OF BETWEEN 2 AND 4 INCHES. NO WATER SHALL BE ADDED TO INCREASE WORKABILITY. TEST CYLINDERS SHALL BE MADE FOR THE STRENGTH TESTING OF EACH BATCH OF CONCRETE FOR AT LEAST 7 AND 28 DAY TESTING. E. SOD: A MINIMUM OF A TWO -FOOT WIDE STRIP OF SOD, OR AS OTHERWISE SHOWN ON THE PLANS, SHALL BE PLACED ALONG THE BACK OF CURB OF ALL CONSTRUCTED PAVEMENT TO AID IN PREVENTION OF EROSION AND SOIL STABILITY. SOD SHALL BE PLACED IN CONFORMANCE TO FDOT SECTION 570, 575 AND 981. GENERALLY, THE SODDING REQUIREMENTS SHALL BE AS SPECIFIED ON THE LANDSCAPE PLANS, PREPARED BY OTHERS. F. SEED, FERTILIZE AND MULCH: ALL DISTURBED AREAS SHALL BE STABILIZED WITH SEED, FERTILIZER AND MULCH UPON COMPLETION AND ACCEPTANCE BY ENGINEER OF FINAL GRADING. SEED, FERTILIZER AND MULCH SHALL BE IN CONFORMANCE TO FDOT SECTIONS 570, 575 AND 981. THE CONTRACTOR IS RESPONSIBLE FOR ESTABLISHING A STAND OF GRASS SUFFICIENT TO PREVENT EROSION PRIOR TO REMOVAL OF THE TEMPORARY SILT FENCES. THIS APPLIES ONLY TO THOSE AREAS NOT COVERED BY THE SODDING SPECIFIED IN THE LANDSCAPE PLANS, PREPARED BY OTHERS. G. TESTING: THE CONTRACTOR SHALL SECURE THE SERVICES OF AN APPROVED INDEPENDENT TESTING LABORATORY TO CONDUCT ALL REQUIRED TESTING ON SUB -GRADE, BASE, ASPHALT AND CONCRETE. LOCATIONS REQUIRED FOR THESE TESTS SHALL BE AS REQUIRED BY THE CITY OF OKEECHOBEE, AND/OR IN THE CASE OF THE TURN -LANE IMPROVEMENTS AS REQUIRED BY THE CITY OF OKEECHOBEE. AT A MINIMUM, TESTING SHALL BE AS RECOMMENDED BY FDOT. SHOULD ANY TESTS FAIL, CONTRACTOR SHALL AT HIS OWN EXPENSE, REPAIR THE DEFICIENCIES AND RETEST THE WORK UNTIL COMPLIANCE WITH THE SPECIFICATIONS IS DEMONSTRATED. H. TRAFFIC CONTROL: THE INSTALLATION OF TRAFFIC CONTROL DEVICES SHALL BE IN CONFORMANCE TO THE REQUIREMENTS OF THE MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES, THE CITY OF OKEECHOBEE. MAINTENANCE OF TRAFFIC DURING CONSTRUCTION SHALL BE AS REQUIRED BY FDOT. 4.DRAINAGE IMPROVEMENTS: ALL LABOR, MATERIALS AND CONSTRUCTION METHODS SHALL BE IN CONFORMANCE TO THE MINIMUM ENGINEERING AND CONSTRUCTION STANDARDS OF THE CITY OF OKEECHOBEE AND FDOT SPECIFICATIONS. TRENCH EXCAVATION AND BACK -FILLING OPERATIONS SHALL MEET OR EXCEED THE REQUIREMENTS OF FDOT SPECIFICATIONS, SECTION 125. THE CONTRACTOR SHALL PROVIDE THE NECESSARY BACK -FILL COMPACTION TESTING REQUIRED TO DEMONSTRATE COMPLIANCE WITH THIS SECTION. THE PIPE TRENCH SHALL BE DRY WHEN PIPE IS LAID AND THE PIPE SHALL BE BEDDED PER THE DETAILS AND PER FDOT SPECIFICATIONS. ENGINEER OF RECORD INSPECTION REQUIREMENTS CONTRACTOR TO CALL CONTRACT ENGINEER OF RECORD 48 HOURS ADVANCE FOR FOLLOWING INSPECTIONS: 1. PRECONSTRUCTION MEETING 2. DRAINAGE PIPE (UNCOVERED) 3. PAVEMENT SUBGRADE 4. PAVEMENT BASE 5. FINAL A. REINFORCED CONCRETE PIPE (RCP): RCP SHALL CONFORM TO THE REQUIREMENTS OF ASTM SPECIFICATIONS C-76, CLASS III, WALL THICKNESS "B", LATEST REVISION. ALL JOINTS SHALL BE SOIL -TIGHT. PIPE GASKET SHALL CONFORM TO FDOT SPECIFICATIONS, SECTION 942. B. CORRUGATED METAL PIPE (CMP): ALL CMP SHALL BE STEEL, ROUND, HELICAL -WOUND CORRUGATED PIPE CONFORMING TO AASHTO-M 36 AND FDOT SECTION 943. PIPE ENDS AT JOINTS SHALL BE REFORMED TO A MINIMUM OF 2 ANNULAR CORRUGATIONS FOR THE COMPLETE BAND WIDTH. ALL JOINTS SHALL BE SOIL -TIGHT. ALL CONNECTING BANDS SHALL BE CORRUGATED ANNULAR COUPLING BANDS. A NEOPRENE GASKET OF AT LEAST 7 INCHES WIDE BY 3/8 INCH THICK SHALL BE USED FOR ALL PIPES OF 36-INCH DIAMETER AND SMALLER. LARGER PIPE SIZES REQUIRE GASKETS OF AT LEAST 10-1/2 INCHES IN WIDTH. ALL CMP SHALL BE INSTALLED AT MAXIMUM LENGTHS TO REDUCE THE NUMBER OF JOINTS. C. CORRUGATED ALUMINUM PIPE (CAP): ALL CAP SHALL BE ALUMINUM ALLOY, ROUND, HELICAL -WOUND CORRUGATED PIPE CONFORMING TO AASHTO-M 196 AND FDOT SECTION 945. PIPE ENDS AT JOINTS SHALL BE REFORMED TO A MINIMUM OF 2 ANNULAR CORRUGATIONS FOR THE COMPLETE BAND WIDTH. ALL JOINTS SHALL BE SOIL -TIGHT. ALL CONNECTING BANDS SHALL BE CORRUGATED ANNULAR COUPLING BANDS. A NEOPRENE GASKET OF AT LEAST 7 INCHES WIDE BY 3/8 INCH THICK SHALL BE USED FOR ALL PIPES OF 36-INCH DIAMETER AND SMALLER. LARGER PIPE SIZES REQUIRE GASKETS OF AT LEAST 10-1/2 INCHES IN WIDTH. ALL CAP SHALL BE INSTALLED AT MAXIMUM LENGTHS TO REDUCE THE NUMBER OF JOINTS. D. CORRUGATED HIGH DENSITY POLYETHYLENE PIPE (HDPE): ALL HDPE PIPE SHALL BE RESIN CONFORMING TO ASTM D3350 MINIMUM CELL CLASSIFICATION 435400C, ROUND, ONLY ANNULAR CORRUGATIONS AND CONFORMING TO FDOT SECTION 948-2.3. ALL JOINTS SHALL BE SOIL -TIGHT. ALL CONNECTING BANDS SHALL BE CORRUGATED ANNULAR COUPLING BANDS. A NEOPRENE GASKET OF AT LEAST 7 INCHES WIDE BY 3/8 INCH THICK SHALL BE USED FOR ALL PIPES OF 36-INCH DIAMETER AND SMALLER. LARGER PIPE SIZES REQUIRE GASKETS OF AT LEAST 10-1/2 INCHES IN WIDTH. ALL HDPE SHALL BE INSTALLED AT MAXIMUM LENGTHS TO REDUCE THE NUMBER OF JOINTS. E. CONTECH A-2000 PVC DRAINAGE PIPE (A-2000): ALL A-2000 CORRUGATED PIPE WITH A SMOOTH INTERIOR SHALL CONFORM TO THE REQUIREMENTS OF ASTM DESIGNATION F949 & F794 DUAL WALL CORRUGATED PROFILE (DWCP) PIPE. PIPE AND FITTINGS SHALL BE HOMOGENEOUS THROUGHOUT AND FREE FROM VISIBLE CRACKS, HOLES, FOREIGN INCLUSIONS OR OTHER INJURIOUS DEFECTS. PIPE SHALL BE MANUFACTURED TO 46 PSI STIFFNESS WHEN TESTED IN ACCORDANCE WITH ASTM TEST METHOD D2412. THERE SHALL BE NO EVIDENCE OF SPLITTING, CRACKING OR BREAKING WHEN THE PIPE IS TESTED PER ASTM TEST METHOD D2412 AND F949 SECTION 7.5. THE PIPE SHALL BE MADE OF PVC COMPOUND HAVING A MINIMUM CELL CLASSIFICATION OF 12454B AS DEFINED IN ASTM SPECIFICATION D1784. F. PVC DRAINAGE PIPE: PVC DRAINAGE PIPE SHALL BE C-900 WITH PUSH -ON JOINTS (NO GLUED JOINTS) AND SHALL BE AS SPECIFIED FOR SANITARY SEWER CONSTRUCTION, EXCEPT THAT IT SHALL BE WHITE IN COLOR. ANY PORTION OF THE PVC STORM PIPE THAT MAY BE EXPOSED TO SUNLIGHT, SUCH AS ITS OUTLET TO THE DETENTION POND, SHALL BE PAINTED TO PROTECT IT FROM UV LIGHT. G. INLETS, MANHOLES, AND JUNCTION BOXES: ALL DRAINAGE INLETS, MANHOLES, AND JUNCTION BOXES SHALL BE PRECAST CONCRETE CONFORMING TO ASTM C-478 AND 64T. ALL CONCRETE SHALL HAVE NOT LESS THAN 4000-PSI COMPRESSIVE STRENGTH AT 28 DAYS. STRUCTURE SECTIONS SHALL BE JOINED WITH A MASTIC SEALING COMPOUND. THE REMAINING SPACE SHALL BE FILLED WITH THE CEMENT MORTAR AND FINISHED SO AS TO PRODUCE A SMOOTH CONTINUOUS SURFACE INSIDE AND OUTSIDE THE WALL SECTIONS. ALL OPENINGS IN PRECAST STRUCTURES SHALL BE CAST AT THE TIME OF MANUFACTURE. HOLES FOR PIPING SHALL BE SIX INCHES LARGER THAN THE OUTSIDE DIAMETER OF THE PROPOSED PIPE. ALL SPACES BETWEEN THE MANHOLE AND THE PIPE SHALL BE COMPLETELY FILLED WITH MORTAR AND FINISHED SMOOTH. MORTAR USED FOR CONCRETE STRUCTURES SHALL CONFORM TO M C-270. MORTAR MATERIAL SHALL BE MIXED ONE PART TYPE 2 PORTLAND CEMENT TO TWO PARTS AGGREGATE BY VOLUME. PORTLAND CEMENT SHALL CONFORM TO ASTM C-144 AND AGGREGATE SHALL CONFORM TO ASTM C-144. THE CONTRACTOR SHALL FURNISH THE ENGINEER WITH SHOP DRAWINGS OF ALL PRECAST STRUCTURES FOR HIS APPROVAL PRIOR TO FABRICATION. SHOP DRAWINGS SHALL SHOW ALL DIMENSION, REINFORCING STEEL AND SPECIFICATIONS. STORM MANHOLES SHALL BE CONSTRUCTED WITH A TRAFFIC BEARING CAST-IRON SLOTTED GRATE. H. TRENCH BACKFILL SHALL BE AS SHOWN IN THE DRAINAGE DETAILS. IN ADDITION, TESTING UNDER PAVED AREAS SHALL BE AS FOLLOWS: ONE TEST LOCATION MIDWAY BETWEEN STRUCTURES AND ONE TEST LOCATION ADJACENT TO EACH STRUCTURE. ENGINEER MAY REQUEST ADDITIONAL LOCATIONS. TESTING IN EACH LOCATION SHALL BEGIN IN THE FIRST FOOT ABOVE THE CULVERT WITH TESTS EVERY TWO FEET TO WITHIN TWO FEET OF THE SUB -GRADE. DENSITY SHALL BE TO 100 PERCENT OF MAXIMUM AS DETERMINED BY AASHTO T-99. I. CONTROL STRUCTURES: SHALL BE CONSTRUCTED PER THE ABOVE SPECIFICATIONS FOR INLETS, MANHOLES, AND JUNCTION BOXES EXCEPT THAT THE STRUCTURES SHALL INCLUDE THE BLEEDERS AND WEIRS AS SHOWN ON THE DETAIL. J. RIP -RAP ENERGY DISSIPATERS: SHALL BE CONSTRUCTED PER THE DETAILS AND AS SHOWN ON THE DRAWINGS AT THE CONTROL STRUCTURES AND THE DOWNSTREAM BUBBLE -UP STRUCTURES. THE RUBBLE SHALL BE OF MATERIAL AND PLACED IN ACCORDANCE TO FDOT SECTION 530-2.3 (MATERIAL) AND FDOT SECTION 530-3.3 (CONSTRUCTION METHODS). SHOULD BROKEN CONCRETE BE USED AS THE RUBBLE, IT SHALL BE FREE FROM REINFORCING BARS OR WIRE MESH. THE CONTRACTOR SHALL USE CARE IN THE PLACEMENT OF THE STONE SO THAT IT IS NOT DROPPED ON THEW FABRIC IN SUCH A FASHION THAT TEARS THE FABRIC. THE FABRIC SHALL BE AS SPECIFIED IN FDOT SECTION 985 AND SHALL BE OF THE WOVEN DESIGN AND AS SPECIFIED FOR USE WITH RIPRAP PER TABLE 1 OF THIS SECTION. THE BEDDING STONE SHALL BE OF THE TYPE TYPICALLY USED FOR DRAINFIELD ROCK AND SHALL MEET THE REQUIREMENTS OF FDOT FOR DRAINFIELD ROCK. 1:7��16`]■�7�I_11G`7�■:i1:Z�7■I■�111[e] NL FND PK # 007 x 105 5 -278 71781F. 6� -6 EV = 28.23' 0 x1278' 27 7.4' 6P7 IQ, No 1 0 W 27.7' x 27.7' 27 7' Q w N� zQ J U U '7.5' f275' �274' 1277' LU Z W Q 0 Z N W Z 27.3' 9' J272' 126.2' 26.1' 25.9' x26. 1 ' x26.0' 26.1' .RK f40002 TAIL & DISC 37 ILLEGIBLE 1058969.50 71181798 � nY - nc zw' MATCHLINE SHEET CD01 MATCHL-INE SEE SHEET CD02 NE STH STREET x274 x 5' CIL NE 5TH STREET (F) CIL NE 1 1 TH STREET (P) 1* x 27.6'-1 _ TOE OF E � � " � n� o _ten' - ' �� - ---� - � � ' .J M� _ - M M M25a�T M M M M M M 4 7 0 " OAK 014 " TREE NO IDENTIFICATION f x26.6' N4 3 n2546,' „E x,95. o'� _ _ x24.9' �9.95 �9 95�Lc .67' �g (GL �95..L�)�,g9.9.5 74' 0 50.00' ( 50.00' (P) 50.00' (P� (� S + FND 518- IRON ROD 024" PINE 074 0/ 010 PINE(l) 3 I NO IDENTIFICATION 020" OAK 018" OA `8„ K 0 032" OA 2" 1 4" OAK 014" OAK I I 0/C"�li 1 24 OAK 1 1 0. 012" OAK I I 018" OAK xPINE 016" PINE O >< 8" OAK 012" OAK J X , - - 6 X OAK EXISTING TREE TO 1 I BE REMOVED, TYP. 1 Vy I 1 0.1 _ 1 1 cM 41 X.. PAR( L /D: 0) 3-15-37-35- 10-01100-0010 O 00 LOT .5 LOT 61- 26.0' O g'+ p +26.6 �.LOT 4 LOT 3 LOT 2 � � LOT 1 7 O BLOCK 110 u a_ BLOCK 110 BLOCK 110 BLOCK 110 BLOCK 110 B CK 1f0 5 1 0 I-[24.3' P.B. 5, PG. 5 - 1 P.B. 5, PG. 5 1 P.B. 5, PG. 5 P.B. 5, PG. 5 P.B. , o o o I N 0 1 O 001 6 1 -23.5' 0.964 CRE` Q0 012 " OAK N 6' M24" oAK +239' (VAC NT 12" OAK o (n o N C-' 032 OAK o 0 1 1 1 016" OAK 1 010" oA�16" OA 0 k I I I 016" OAK 010" OAK 20" OAK �n ro 0 FND M2" IRON ROD & CAP o STAMPED "BSM LB 8155" BLOCK 110 B. 5, PG. 5 I 016" OAK 012" PINE NI 1 018 OA1(2" PALM N1 022" PINE1 0 + 016" OAK > �� 076" OAK 0/0" OAKO� 74" PALM + 7 +26 ) 49.96' (C) +24.3' 49.96' (C) 0, „ 14" %AK�O 49.96' (C' 49.96' (C) x OAK4 50.00' (P) 50.00' (P) �- 50.00' (P) 29g. 50.00' (P) �� 50.00 (P) 5 .00' (P) _ -- --�2PALM-- -- - N89° 45' 46"E �- -- -- -- -- 20 " OAK 010" OAK -23.6' PALM 016" PINE +24.2' 3' 8" OAK_72OAK 0 1o"TREE N89° 45 46 E 49.96' (C) 49.96' (C) -_49.9/-299.75' 0 49.96' (C) 49.96' (C) 476_(C) 50.00' (P) 50.0( P) 012"T 1450.00' (P) 50.00' (P) 50.00' (P) 12 "OAK OAK - __ � 014 " OAK �n i -I 048" OAK 16" OAK U) FND 712 " IRON ROD & CAP I f 2 " OAK STAMPED 'BSM LB 8155" 078" OAK x ,�� OJK 6„ PINF6.7' -25.9' 4" I vy 24.2' 2 " OAK X PIN 6" PALM 1 „ OAK +24.2' +24.9' 2" OAK 0.965 1 CRES f )LO OA (VACANT) 1 I 0/0" *11 0� 1 OAK I 1 .��� I I 1 OAK 022" OAK 016" OAK OAK I LOT 7 LOT 8 LOT 9 LOT 10 LOT 12 BLOCK 110 BLOCK 110 BLOCK 110 BLOCK 110 LOT 11 0 24 " OAK BLOCK 110 PG. 5 P.B. 5, PG. 5 P.B. 5, PG. 5 012 " OAK P.B. 5, PG. 5 BLOCK G. 014 " PV P B. 5, PG. 5 P.B. 5, PG. 5 014" 0,', M p �� I �y 1 PARCEL Q O O o -15-3 -35-DO 10-01100-0010 0 0 1 � --16 " OAK 0 1 0 No Not +25. ' 1 00�1 "2" OAK 1 001 0 016" OAK o0 �' � 016" OAK x OAK Lam`' .9, i/i 010" OAK � "OAK �20" OAK x OAK 14" R4 !y 1 1 0 �44»0 K +23.2' 12„ PALM �0 u 23.1' 4" PALM 1 6" TREE I 070" OAK 0 I 1 2" OAK 0 0 PALM 24" OAKM 0 0IPSTING TREE TO BE REMOVED, 014" TREE 024" OAK 014" OAK 4 2" AK +24.4' I 2" OAKJ +24 1' 016" OAK 2" PALM I 1 1 FND 112' ON ROD & CAP STAM 'BSM LB 8155"� BNK4 Z �' EL . = 2, 4' 4029 26.1 V 1 , 78" CMP 26 2, CHK 0004 XINiV ELEV. = 23.25' k25-426. 0'x26.2' 2 1' ,25.8' ELEV. W 23.34' 3.8' 5.3, PALM 3 N 25.2' 25.8' 25 7' 3 ' 3.9' ` 5.3' Cn Cn x 24. Cn Cn FJ 712" WON R D CAj S A MPED-,�" SM LB 81 5" 026 A W Q� CC LQ o z� 3 4.7' �JJ x 2BNG4 U) `f x24. ' � 4.2' U 25.5' 26.0 25. w Cn Q �n NQ LPL AND 112 " l ON ROD �TA PED " M L + 4, Z 3 x . 4.9' x 25.797 BIiC4 W 3 Cn (/) �� 25.8' x26. 1 ' 25. 5.8' MI M ' FND 518-IRON ROD S s 014 _ I !I -NO IDENTIFICATION ®X6" OA ;S +23.0' 18" 072" PALM ALM 12" TREEELM +26 25 3' 237'+49.97' (C) i 49.97' (C) -12" LM49.9 (C) 49.97' (C) 49.97' (C) ZPA�� �, omml 16 TREE S89° 47' 51 78" CMP 0' 016" PALM INV. ELEV. = 22.52'� w w w w w w w x2 w w x24.1 ' w x24.0' RIM ELEV. = 23.43' I w w TOE OF SLOPE %26. C + 4 29 lit o S 78" RCP S IN 1AV VtVEV-=1 25.39 21 25.395 3 2 BINO� BINCA ENiC6 NE 4TH STREET GRAPHIC SCALE 20 0 10 20 40 80 ( IN FEET ) 1 inch = 20 ft. 26.0' 126. I' ' 25.8' x26.0' ELL2 .2 1`.,;1I I:�a•�yn��nrar��naarzynn�mre� 1 -0-0-0-0-0��-0--o- PROPOSED SILT FENCE X250 EXISTING TREE TO BE REMOVED Isom KEY MAP SCALE: 1.250 MATCHEINE SEE SHEET CD®126.34' MATCHEINE SHEET CD02 #1118 )69.46 317.89 26.31 ' gD ,K25. 7' �c (BASIS OF BEARINGS) 400M o CIL NE 4TH STREET (F) N E 4TH STREET I ; SITE BENCHMARK 40001 CIL NE 10TH AVENUE (P) 2. 7 5 8 3 25 uu,' ° fU 25.7' F25.8';25.9' ul D Q 0 N W Z r 0 0 W w �� o Q W Q zJ J� 5.7' }26.7' 26 RIM ELEV. = 25.57' STAMPED LB 8155" 18" RCP N INV. ELEV. = 18.48' BwC N. 1058946.21 g s 25.5 25.616 5' RCP W INV. ELEV. = 78.62'- E. 711990.68 5' RCP W INV. ELEV. = 77.58' ONIJ 5' RCP E INV. ELEV. = 18.62' _ f 5' RCP E INV ELEV. - 17.5B' 25 ELEV = 25.21 ' -l�I D SD SD SD SD SD SD SD SD SD SD 3D 3D 3D 3D SD SD SD SD D SD SD 3D 3D SD SD SD 3D 3D 3D 8D 8D 8D 3D 3 BD 3D SD to SD- -�=.v' - - - - 25. ' o-■z�4-�' 23.6' 3 25.6' g®Fa® ®® 25.9 V) 7 X24.5' -24.9' X24.4' �. ovr 2 o�mo x • I °� 2 •r-I4, 677 ouH ovno ovno,rj, Q'mo ovho ovHo o�mo oero oero ovno 0 ovno o�mo �- 2-4,®��¢ 01}10 S m �.� IY� �,�" M 7 �-� 24.976 ® �� OHU ° +24,9' FND "" IRON ROD 25.3 �� 25.1 ' q 24.8' �a �R> N(L, DDTIFICATION q� + 2 .OX2 .2' 6 �' LEANING o4 89 47 50 I ( ) 4750.00' (P) 50.00' (P) 50.00' (P) 50.00' ( 50.00' (P) 50.00' (P) F D 2" S A " I I I ® MD I I � ; 5 � FND 1/2" I RON ROD &CAP [MI I I S I IS �T/OC(l S S I I 24.7' � -25.3' 116-0 I I I I i 6 OAP I I XI I I,�0 < + 5.6' 25.5 vy XTFENCE, TYP.-2IJ +25.0' .�� r24.8' ^� � i EXISTING TREE TO BE REMOVED, R ES + TYP. 1 NT) I ' .-. - _ �a- 0 C +24.4' 2 LOT 6 to o LOT 5 (0 o LOT 4 m o LOT 3 � o LOT 2 � �® BLOCK 121 0 o BLOCK 121 0 o BLOCK 121 0 o BLOCK 121 0 o BLOCK 121 0 o BLOCK 121 0 P.B. 5, PG. 5 o Ln P.B. 5, PG. 5 P.B. 5, PG. 5 Ln L P.B. 5, PG. 5 P.B. �5, PG. 5 1 1 P.B. 5, PG. 5 w 030 I � I e`�' X OAK I T r 0 3 UAK 6 " TREE ' PARCEL ID: I I PARCEL ID. I PARCEL I Q I PARCEL ID. ' 3-15-37-35-0010-01 10-0060 3-15-37 5-0010-01210-0040 3-15-37-35-001-01210-0030 3-15-37 35-0010-01210-0010 I CD -25.3' ' TREE �y 014 25.7' ,i, i 1V +25. O -25.5' +25.2' -24.3' X24 ' o' I 25.2' I I I I I BLOCK 121 P.B. 5, PG. 5 N 2 III �: 7.2' 27.5' 1 ' 27.2' 1 4276 #40003 N: 1058569.53 711819.30 27.85'R FND 112" IRON ROD & CFND 112" IRON ROD & CAP /II STAMPED 'BSM LB 8755" I STAMPED 'BSM LB 8155" 1 16" OAK O I I I I I 49.97' C 49.97' C 49.97' C 4 .97' (C)4" O� 50.00' (P) 50.00' (P) �_W_y 50_00' (P) z 50_00' (P) �_W 50.00' 2(y d_ 50_00' (P) +25.6 - - - - 3 Vy 125. 1' S89• 49' 44"W 25,8' � �%D 12"IRON ROD & CAP -25. 1 ��� 25.0' 24. 1' ; 0»ED 'BSM LB 8155" i9' _ _ S89 _49' 44"W_ 0 ` -- _ _ _ _ _ P 01 49.97' (C) 49.97' (C) fi 49.972pp 84' 49.97' (C) 49.97' (C) 4 - - 50.00' (P) 50.00' (P) I - 50.00 50.00' (P) 50.00' (P) 50.00' (P) I I I I I X24.6' 016" - FND 112" l ON ROD & CAP1 012" TREE I I I STAMPED "BSM LB 8755" --4 EXISTIN ASPHALT TO BE REMOVED 016" oA 012 TREE 72" OAK 1 .033 ACRES + -" OAK (VACANT) 3 +26.0' 4 " 0 I 20 " PINE 26. ��7 +25.9' +25.7' +25.0 2" PA s - + 0 �3 IN LOT LOTLOCK 1121 1121 1121 BLOT I I BLOCK 1 BLOCK {' NE P.B. 5, PG. 5 P.B. 5, PG. 5 I P.B. 5, PG. 5 O I . 4 o` ., �,. . C c� o OCD .� ` .. LC) O N O � 0 w O 7O 7O 31 0 00 00 00 PARCEL ID. ll PARCEL ID: 24• 9 4-O 3-15-3T-35-0010-01210-0120 - - 3-15-37-35-0010-012 100 in 25.5' 26.6' 26.7' I 018" PALM I ROD & CAP LB 81t5" 708 9' I 5.912 ml Cn :26.3' J26. 1 00 n 0 0 0 oW o �L 0 o Z z� 2W' 26.8' Lu M Z N &5' 126.8' 1,26.6 W �A X2 2' 4.7' x � '53 X25 2' 1 ' XISTING TREE TO BE REMOVED, 1 <r 9 TYP. ' 5.974 0 FND 1 " IRON ROD ' 4 8' *26.5' NO IDENTIFICATION -25.0 �l +ems 26.6' �-25.6' � -2 .5' 25.9 - 49.97' (C) 49.97' (C) 49.97' ) S I �OCI"CP) �25'M_T0.0m(Pr X2 4 X wti X25.5 X N890' "C (0) 4'_ ��€"1�T, - roE of sLOP _ - 25.6 299. 7.2 6 w w w w W 2 .436 X 26.5' monsom �2"ADD STAMPED 'BSM LB 8155" w w W_ EDGE OF PAVEMENT - NE 3 R D STREET RRQ'9i,l "_17"W - Frq 94' '•7I W*1'i GRAPHIC SCALE 20 0 10 20 40 80 ( IN FEET ) 1 inch = 20 ft. SO" CMP X26. INV. ELEV. = 25.4 ' 6.7' 7 126.9 e N 01 -1 9-202 I 0LV S-D P ANS -�EF 0C M-L. NC X250 EXISTING TREE TO BE REMOVED \\\\\\\\\\\ • G ► O ASPHALTD KEY MAP SCALE: 1:250 EXISTING SIGN TO REMAIN GENERAL PURPOS REA PROPERFY LINE, TYP. PROPOSED CROSSWALK tAWCUT AND MATCH EXISTING PAVEMENT I PERIMETER BERM, I G ERAL PURPOSE PROPOSED CROSSWA 1 AWCUT AND MATCH XISTING PAVEMENT ADA I RAMP TYP. M I N Z GENERAL PURPOSE AREA C Z M PRCIPOSED CROSSWALK AWCUT AND MATCH XISTING PAVEMENT GENERAL'PURPOSE AREA EXISTING SIGN TO REMAIN MATCHLINE SHEET C201 MATCHLINE SEE SHEET C202 GENERAL PURPOSE AREA NE 5TH STREET SAWCUT AND MATCH EXISTING PAVEMENT GENERAL PURPOSE AREA v ° 27 PROPOSED CROSSWALK W 4 p ° p > ° ° • r. T I VM3akl; ° °s ° p �> s ° pv MII M341S ,S >'dObd s • p v v V v ° �s e ° ,9 ,dOOd v • ° ps > s p s • 7 s 5, 50.17' 124.22 0 > d 4g PROPOSED WHEEL STOI ITYP. o 9' PROPOSED v I p3 0 27' I WHEEL STOP TYP. 15 Lt�] 5 W 11.58' 11.58' (� 20' FRONT YARD SETBACK & SANITARY SEWER EASEMENT 20' FRONT YARD SE BACK & SANITARY SEWER EASEMENT 'n I PROPOSED WHEEL STOP TYP. 6.17' CD 1 3.83' I 27' • s va s 21 48.67' 6,7 38.72' PROPOSED 37.94' 8.67 48.67' 9' 0 N I BUILDING I N co (1575 SF) I PROPOSED s Q PROPOSED PORCH/PATIO 3' BUILDING PROPOSED (105.51 sF) PROPOSED 3' N N o N (1931 SF) PORCH/PATIO o o fi N BUILDING o _ (105.51 SF) (1931 SF) _ 1.00' LOT 1.00' LOT 12,492 SF , 9' rn oa N 12,578 SF N g, p h r6 48.67' a I I 48.67' 20.00' 15.08' 15.08' SECOND FLOOR PORCH WITH q 27' CONCRETE PATIO BELOW SECOND FLOOR PORCH WITH PR POSED 2.17' CONCRETE PATIO BELOW N P CH/PATIO I PROPOSED ( 05.51 SF) WHEEL STOP TYP. I w PROPOSED I o WHEEL STOP TYP. SECOND FLO R PORCH WI H I oN CONCRETE P 10 BELOW in f 24.55' 125' I 4 O� 4 I PROPOSED LOT 00 od I PROPOSED I 5' ° WHEEL STOP TYP. 0 12,439 SF o LOT WHEEL STOP TYP. t , 12,476 SF lo p 27 N I 8.6,7' 38.42' 48.67' PROPOSED BUILDING PROPOSED r (1931 SF) PORCH/PATIO (105.51 SF) aN 48.67' SECOND FLOOR PORCH WITH D I CONCRETE PATIO BELOW m LOT o 7,553 SF o P 0POSED PROPER LINE, TY . N 7,495 I SF 1167 N PROPOSED PORCH PATIO (105.51 SF) e }I N .I •. SECOND FLOOR PORCH WITH CONCR E PATIO BELOW Ln 27' v 29' 48.67' �. 0 2 PROPOSED 3' BUILDING o 0 (1931 SF) 1 .00 co II 's. Y w TYP. N 01 PROPOSED w PJ Y 2I WHOEEOLSSTOP WHEEL STOP TYP. N •Q w Q m :2 w m I Q u~' A / w u' z w cn d (n w ro 124.7' 124.89' � LL W " w DRAINAGE EASEMENT w CL 0 a n n � o U SECOND FLOOR PORCH WITH I° zQ PROPOSED CONCRETE PATIO BELOW PROPOSED ,a WHEEL STOP TYP. N WHEEL STOP TYP. PROPOSED °5 •5' PORCH PATIO 12.17'. (105.51 SF) b .. 27' ° s > 27 4.98' 20.00' 1 .08' ° 29' 48.67' 8, 6,7 38.25' 38.62' 8. c7; 48.67' 9' v .... I cc N PROPOSED N• 00 BUILDING LOT II �s. LOT (1575 SF) 12,504 SF 3' PROPOSED 12,506 SF PROPOSED 3 M BUILDING o PROPOSED BUILDING N g N (1931 SF) �' ° ` ;� P POR H/PATIO (1931 SF) N PROPOSED (105.51 SF) 1 .00' PORCH/PATIO 1 .00' (105.51 SF) ` o 9 I 9 a� SE 0 D FLOOR PORCH WITH N 48.67' r2 J° 48.67' CO JCIRETE PATIC BELOW s' w o I I 1 3.83' `? 6.17' 1 20' SANITARY SEWER EASE ENT IN FAVOR OF A FUTURE HOA Ld SECOND FLOOR PORCH WITH U) 15 CONCRETE PATIO BELOW REPAIR/REPLACEMENT OF SEWER LINES FOR THE PROJECT 5' w in 15' REAR YARD SETBACK 11.28' 11.58' • � 27' 15' REAR YARD SETBACK N °N TED 0 PROPOSED WHEEL STOP TYP. � PROPOSED WHEEL STOP P. CE Ln WHEEL STOP TYP. p Lo 1 24.8' 9 5' 49.78'Ti -Ir p s ° • e s ° g1i7b'M3®I� ,6 pdp2i,d e ' s s v e p , p e ° p V. ° ' v v " ° > ;>i.�b'M341S ;� 'd021d • v > v e • p V s V. •� v °> v Y J 'Ld 27' PROPOSED CROSSWALK w J o w N s r� 9. 0 s d dp Rr` Of Cl- GENERAL PURPOSE AREA SAWCUT AND MATCH EXISTING PAVEMENT NE 4TH STREET GENERAL PURPOSE AREA GRAPHIC SCALE 20 0 10 20 40 80 ( IN FEET ) 1 inch = 20 ft. LEGEND ASPHALT PAVEMENT CONCRETE WALKWAY a e ENERAL PURPOSE AREA ADA RAMP TYP. LANDSCAPING AREA -PROP. DEPRESSED CURB TYP. PERIMETER BERM -SAWCUT AND MATCH EXISTING PAVEMENT PROPOSED CROSSWALK ENERAL PURPOSE AREA PROP. DEPRESSED CURB TYP. -PROPOSED CROSSWALK SAWCUT AND MATCH EXISTING PAVEMENT ENERAL PURPOSE AREA Z M N v Z C m PROP. DEPRESSED CURB TYP. SAWCUT AND MATCH EXISTING PAVEMENT PROPOSED CROSSWALK z W c� d z ti W GENERAL PURPOSE AREA EXISTING SIGN TO REMAIN I:�a•�yn��nrar��naarzynn�mrel SCALE: 1 :250 Project Name: Glenwood Park, LLC Owner Name: Mitch Stephens Owner Address: 17705 Middlebrook Way, Boca Raton, FL 33496 Owner Phone: 91 9-201 -991 3 Engineer Name: Steven L. Dobbs Engineering, LLC Engineer Address: 1062 Jakes Way, Okeechobee, FL 34974 Engineer Phone: 863-824-7644 Architect Name: N/A Architect Address: Architect Phone: Planner Name: N/A Planner Address: Planner Phone Block 110 Future Land Use: Multifamily Zoning: Multifamily Min Lot Width: 100,0 ft Proposed lot Width: 300.0 ft Min Lot Size: 7,495 sf Proposed lot size: 90,043 sf Project Size 2.07 AC Total Duplex Units: 6 duplexes - 2 single family houses Setbacks: N Front Reg 20 Provided 20 W Side ReQ 15 Provided 15 E Side Reg 15 Provided 15 S Rear ReQ 15 Provided 15 Coverage Residential Allowed 84% Proposed: 1 6% Proposed Bldg: 0.34 cc Impervious Area Allowable Impervious Area: 76% Proposed ISR: 24% Roofline/Bldg: 0.34 cc Pavement/Sidewalk 0.15 cc Total Impervious: 0.49 cc NOTE: THE PROPERTY CAN BE DIVIDED IN THE FUTURE, IF THE OWNER DESIRES. INDIO MATCHLINE SEE SHEET C201 MATCHLINE SHEET C202 EXISTING SIGN EXIST. GUY WIRE TO REMAIN GENERAL PURPOSE AREA EXISTING SIGN TO REMAIN SAWCUT AND MATCH EXISTING PAVEMENT PROPOSED CROSSWALK PERIMETER BERM, GENERAL PURPOSE AREA SAWCUT AND MATCH EXISTING PAVEMENT PROPOSED CROSSWALK - PROPERTY LINE, TYP.- GENERAL PURPOSE AREA PROPOSED CROSSWALK SAWCUT AND MATCH EXISTING PAVEMENT ADA RAMP GENERAL PURPOSE AREA EXISTING SIGN TO REMAIN GENERAL PURPOSE AREA LO U N 0 o N N ma's_ h s. C � O N s. NE 4TH STREET _____—SAWCUT AND ExSTNG PAVEMETTH 27' PROPERTY LINE, TYP. ONE v • I • • v V 7 60.67' 9' PROPOSED WHEEL STOP TYP. PROPOSED WHEEL STOP TYP. � I 27 18.3,5 o 20' FRONT YARD SETBACK & SANITARY SEWER EASEMENT N 1 3.83' 0 6.1 7 7 PROPOSED 1 BUILDING (1575 SF) 8.s,7 48.67' c 1s LOT 1 I 12,649 SF 3 PROPOSED BUILDING � _ PROPOSED o (1931 SF) 2 PORCH/PATIO I (105.51 SF) 1 .00' 1 k � 1 ' � 48.67' aN 19.98' SECOND FLOOR PORCH WITI CONCRETE PATIO BELOW // oSWALES z 'PROPOSED WHEEL STOP TYP PROP PORCH (105.5 IV PATIO LF) Q � (P- SECOND FLOOR PORCI WITH w Ld w CONCRETE PATIO BE 0 Q Z — — 20.03'LLJ — — — — Q3;: w ��it �v) W rn w - ol o M IQN PROPOSED WHEEL STOP TYP. co 0 ,N PROPOSED PROPERTY LINE, TYP. 48.67' 8.6,7 33.42' ••: N LOT Co LOT i 9,561 SF 3' PROPOSED 12,537 SF ,r`', _ — 60.67' BUILDING — (1931 SF) � � PROPOSED PORCH/PATIO ° (105.51 SF) •• 9' O� ti M 48.67' aN v O N ° 27' � > °ICI SECOND FLOOR PORCH WITH F I , PROPOSED WHEEL STOP TYP. CONCRETE PATIO BELOW I ID N � "u5 I 1 19.7' LOT 9,559 SF `a 'o PROPOSED WHEEL STOP TYP. SECOND FLOOR PORCH W H CONCRETE PATIO BELOW • _a PROPOSE p N PORCH/P 40 o (105.51 F 27 p •s 2 ' 8.6J 12.17 . 48.67' .a LOT co ; R • 12,579 SF I 18.81' 20.00' e 3 PROPOSED PROPOSED PROPOSED N N O BUILDING PORCH/PATIO BUILDING (1931 SF) (105.51 SF) (1575 SF) 1.00' O J R g' m I 48.67' 5 I o 9 SECOND FLOOR PORCH WIT °� CONCRETE PATIO BELOW 13.83 O 6.17 15' PROPOSED WHEEL STOP TYP. n C M 15.31 ' I N EXIST. GUY WIRE 15' REAR YARD SETBACK 27 p � PROPOSED WHEELS P TYP. 9' o 4, g2 v 1 19.37 60 64' p .p n ° 5flVM11IS1,6 'd0Q- / • v ° ° ° • cc, / k o:• :•.� / / PROPERTY LINE, TYP. 27' 7 c . R1� GENERAL PURPOSE AREA GENERAL PURPOSE AREA / v \Y w 0 N in PROPOSED CROSSWALK vQ a s p AliM341S Y 4 w• O PROPOSED WHEEL STOP TYP. N P,0 LO ,p s 7.69 20' FRONT YARD SET13ACK & SANITARY SEWER EASEMENT a v LOT 12,527 SF 27' °5' 32.54' 6.67°, 48.67' 9' � v O' IN 5 PROPOSED 1.00' PROPOSED BUILDING I CD PORCH/PATIO `' 1931 SFQo (10 .51 SF) 6 ( ) N 3' Q r q CO N � 9 69' 48.67' o v N S CND FL OR PORCH WITH C CRETE DATIO BELOW It I PROPOSED WHEEL STOP TYP. U J r� � CJ ¢ w m � � � w Q w .� 9.14' N / w LLI � I Q av w PROPOSED WHEEL STOP TYP. N Q I 0 a o N DRAINAGE EASEMENT °5 n 27• - 8.67,' 9' 48.67' LOT _Co 5 12,527 SF 1.00' �s PROPOSED PROPOSED o PORCH/PATIO BUILDING N (105.51 SF) (1931 SF) I 3 00 q. N � 9 48.67' v j Ln 0 � N p N s SECOND FLOOR PORCH WITH I ETE PATIO BELOW PROPOSED WHEEL STOP TYP. CON ° I w 0 >� — — — — 119.47' — — — LO I O PROPOSED WHEEL STOP TYP. a 5' N„ 8.67, 9' 48.67' ° � LOT N _ N 12,559 SF 0' < � 's_ 86' 1.00 I PROPOSED Ln PROPOSED PORCH/PATIO ? BUILDING `° (105.51 SF) � (1931 SF) C,� N Uj O � 3' I D � 00 9 N � 48.67' o •J N SE 0 D FLOOR PORCH WITH PROPOSED WHEEL STOP TYP. C RETE PATIO BELOW 20' SANITARY SEWER ASEMENT IN FAVOR OF A FUTURE HOA 'n ao REPAIR/REPLACEME � 0' OF SEWER LINES FOR THE PROJECT 1 5' 0. 18.36' I 15' REAR YARD SETBACK N 1 19.81 I , p ° PROPOSED CROSSWALK SAWCUT AND MATCH (7 5' EXISTING PAVEMENT p• GENERAL PURPOSE AREA GRAPHIC SCALE 20 0 10 20 40 80 ( IN FEET ) 1 inch = 20 ft. fGENER L PURPOSE AREA LEGEND ASPHALT PAVEMENT CONCRETE WALKWAY ° LANDSCAPING AREA PERIMETER BERM ADA RAMP TYP. SCALE: 1 :250 PROP. DEPRESSED CURB TYP. Project Name: Glenwood Park, LLC Owner Name: Mitch Stephens Owner Address: 17705 Middlebrook Way, Boca Raton, FL 33496 Owner Phone: 919-201 —9913 SAWCUT AND MATCH EXISTING PAVEMENT Engineer Name: Steven L. Dobbs Engineering, LLC PROPOSED CROSSWALK Engineer Address: 1062 Jakes Way, Okeechobee, FL 34974 Engineer Phone: 863-824-7644 Architect Name: N/A GENE AL PURPOSE AREA Architect Address: Architect Phone: Planner Name: N/A Planner Address: Planner Phone Z Block 121 M Future Land Use: Multifamily v Zoning: Multifamily PROP. DEPRESSED CURB TYP. / \ Min Lot Width: 100.0 ft Z Proposed lot Width: 300.0 ft m SAWCUT AND MATCH Min Lot Size: 9,561 sf EXISTING PAVEMENT Proposed lot size: 94,498 sf PROPOSED CROSSWALK PROPERTY LINE, TYP. Project Size 2.17 ac 6 duplexes — 2 Total Duplex single family Units: houses Setbacks: N Front Req 20 Provided 20 W Side Req 15 Provided 15 GENERAL PURPOSE AREA Req E Side 15 Provided 15 Rear Req 15 PROP. DEPRESSED CURB TYP. Provided 15 PROPOSED CROSSWALK Coverage Residential Allowed 84% z Q Proposed: 1 6% W Proposed Bldg: 0.34 ac U SAWCUT AND MATCH EX4STING PAVEMENT Impervious Area zAllowable Impervious Area: 76% ti W Proposed ISR: 24% Roofline/Bldg: 0.34 ac Pavement/Sidewalk: 0.15 ac Total Impervious: 0.49 ac GENERAL PURPOSE AREA EXISTING SIGN TO BE RELOCATED NOTE: THE PROPERTY CAN BE DIVIDED IN THE FUTURE, IF THE OWNER DESIRES. 7 LF 12" CMP INV. EL.= 24.00 7 LF 12" CMP INV. EL.= 24.00 27.4' 27.6' 7�3' 27.4' INLET TYPE E GR. EL.=24.00 INV. EL.= 22.20 TDC:28.12 BDC:28.00 40 LF 12" CMP 27.7' x27. INLET TYPE E 27 ' GR. EL.=24.00 INV. EL.= 22.20 27.8' 22' m Z v D rn Z C INLET TYPE E rn GR. EL.=24.00 INV. EL.= 22.20 .5 T C:2 27.5' -- SAWCUT AND MATCH EXIST. PAVEMENT 40 LF 12" CMP INLET TYPE E GR. EL.=24.00 INV. EL.= 22.20 INLET TYPE E GR. EL.=24.00 INV. EL.= 22.20 SAWCUT AND MATCH EXIST. PAVEMENT 40 LF 12" CMP INLET TYPE E GR. EL.=24.00 INV. EL.= 22.20 10 LF 12" CMP INV. EL.= 24.00 MATCHLINE SHEET C301 MATCHLINE SEE SHEET C302 40 LF 12" CMP NE STH STREET r2 ?. °' -2 7. x2 � - INLET TYPE E GR. EL.=24.00 INV. EL.= 22.20 ' TDC:27.00 co 11 I8" cMP 26.2' INV. ELEV. = 23.25' BDC:27.12 INV. EL.= 24.00 24.00 24.0 24.00 ° 6.1 ' x27.6' �.� ex®�®[ :03'' 23.25' ea®� e�'ee �27.7' x26.2' x25.3' 24.7' 24. 1 ' 24.0 x 3 >< x SO SD SDt2. SD- 7 ° 28.02 b ' ° Xo27.6� x ° °° 27.92 ° v ° ° ° ° ° ° 24.5 x26. ' 25.8' .7 ° ° ° ° ° A�27.55> ° ° ° ° ° °> 27.5 p 23;50 ° x?5.0: °° ° > X 26.58 ' ° ° x24.9' ° ° ° °25.91 - - - - - - ° 18' P �5. TI, INV. ELEV. = 23.34' + 7. °° 3.9% 3.9% ° 8 LF 12" CMP INV. EL.= 24.00 ° 2 .6' PERIMETER BERM TOP I 5% 5% I LP 27.00 27.0 28.00 __ LP LP IN E E LP ® 24.0 28.00 27.5 HP 28.18 27.50 GR. E .=24.00 I ° I I I INV E .= 22.20 �I®®e Elm 0000 ui 24.0 28.32 I I 27.37 TDC:25. 2 0.2 % T 28.35 A A A A 2% HP 3 g% 27.47 BDC:25 30 0.5% In 2% - 0 v5% F.F.E. = 28.40 F.F.E. F.F.E. = 28.40 10 a 28.40 I 8.20 \5'25.8' 25 7' 2.0'SAWCU AND MATCH +26.6' I I e Vo ° EXIST. PAVEMENT a• 24.3' ao �n 24.6' 26.00� e�ueae iea• 23.5' 24.0 ° 28.00 27 27.0 ° 24.0 4 L 12" CMP 7.6' 28.00 ° > LP I 23.9 ' I A LP I LP co I A cn I L TYPE E °° 24.00 6.25 I I V. EEL =2 22.20 X27.60 -- - -- -- -- -- -- -- °f26.20 I LU TYPE E ° Z R. EL.=24.00 ° I LP INV. EL.= 22.20 ° 24.0 LIP 2® T24.0 28.00 I N LP 27. 2® LP C� ° IN 26.50 I 26.0 '�I ME 0 ° 'm[ N 4. + +24.300 < rn ' rn I e op 24.7' x 4. a• 0 o A I rn M N , 28 30 I 27 57 BDC:25 50Z INLET TYPE E GR. EL.=24.00 INV. EL.= 22.20 8 LF 12" CMP ,.2/.au 28.2 H 28.30 H 2.6% 27.67 2Z' 26.0 25. � 4% 1% F.F.E.=28.40 - - - F.F.E.=28.40 2% 10% R1 8.20 U 7.7' 27.3' 0.0 A e rn rn a EXIST. 4WC T AND MATCH PAVEMENT 4.0 O I O J ° 0)Oo ° SWALE I ° 4 LF 12" CMP ° I 0.192 AC I U 8.0o I 2A I 27.0 ® 28.00 26.0N 24. 0 +26.7' ° ° 25.9LP LP LP. I +24.2' +24.2' A 24.9' I 24. ° I PERIMETER BERM TOP I I L TYPE E R. L.=24.00 ■ I7-TOP ELEV.=25.00 I - - - - - - EL.=27.00 - °+2s2o f 25.00 I V. �L= 22.20 27.3' B X ° 27.30 - - - - - - - 0 BOT ELEV.=24.00 0lo I ° x2,5. 24.9' 1 ° I O O It 8° LP° 27.5 A I �24.00 I N +23.6' ., . 26.9' 127.2' 26. ' v +24.9' TDC:27.02 �6 BDC:26.90 28,0 28.10 H 1 0.5% 28.20 5% 2% F.F.E. = 28. 40 26.00x2 2' F.F.E. -� 28.40 ci Elm 124.00- 27.0 27.68 P •' 27.50 ® 27.50 LP LP l I PERIMETER BERM 2.8% ° . O �TOP 3EL=27.00 23.0' M 2.8% 2 .0 �25.3' X 26,66 ° ° ° ° F • X 26.83 ° 26.2' 26.0' INLET TYPE E GR. EL.=24.00 26.1 ' INV. EL.= 22.20 -\ 26.0' 5.9' x26.1 X 24.00 °24 0 24.00 x23.8' x23.4' °1�__ 24.00� 26. 1' 8 LF 12" CMP INV. EL.= 24.00 N27.28 04 04 s� 11 II 26.0N 27.0 ° °LP JI J LP 2® N Lv I LLJ I 24.00 oN $$ ° 25.8' x26.1 ' , 25. 5. 0 blo m e OR IN It LET TYPE E G R. L =24.00 27.92 I V. = 22.20 2% H 0 9% 28.02 TDC:25 97 BDC:25 85 F.F.E. = 28.40 z J3.1 ' 10% Q 8.20 ° S VV11,1 T AND MATCH E ISM. PAVEMENT wo 00 M v:P 2 PROPOSED CONTROL -24• 1 m 11 12" CMP 7.00 STRUCTURE (CS-1) I GRATE EL.= 26.50 _ -2 27 0 24.00 w INV. EL.= 24.00 _T LP, It LET TYPE E R. E .=24.00 It V. EL.= 22.20 7 LF 12" CMP ° ' ° ° ° ➢ f26.33. "' ° °. ° ° ° f25.66' INV. L= 24.00 .(fib ° ° lb s IN EV = 2 2.52 :26.0'x26.1 ' 32 LF 18" ADS PIPE 8 LF 12" CMP x25. x2 S.4' 25.8' x26.0' x2 INLET TYPE E x24.1' x24.0'INV. EL.= 24.00 GR. EL.=24.00 INV. EL.= 22.20 23.36 D -e" SD a v�" ®11;M . • 3 x 2.3 22' 2 ° Amp °° ° vMM 24.00 24.0 22.5 RIM ELEV. = 23. 6' o 12" CMP BTDC:25 92 DC:25.80 \ 18" RCP S INV. ELEV. - 78. 6' ° y NE 4TH STREET 125- 5' Z15 7,5.8' .8' 01 -' 9-202 I tEVISLD P ANS L-� I -tC MLLI ING LEGEND X 31.20 PROPOSED ELEVATION X 32.64' EXISTING ELEVATION FLOW DIRECTION ❑O PROPOSED DRAIN INLET cw PROPOSED MSE PROPOSED DRAIN PIPE PERIMETER BERM SCALE: 1:250 a i t w I-- w z O z J 5' J 5' J z D.E. D.E. z w w 10' SWALE Q Q w w MATCH MATCH EXISTING EXISTING GRADE 3:1 3.1 GRADE ----- BOT. EL. AS REQUIRED 09/22 I -#- TYPICAL SECTION A -A T N=All ROADWAY ASPHALT PAVED ± 19' SLD I PDC MATCH EXISTING GRADE 15' SWALE 3: � 3•.1 I MAX Mp,X BOT. EL. AS REQURED w z PROP. 5' w SIDEWALK o PERIMETER BERM w @ TOP EL. 27.00 7, (SEE DETAIL) PERIMETER (TT BERM 2/0 MATCH EXISTING GRADE TYPICAL SECTION B-B 0NTS - - ..S. NEWLINES MATCHEINE SEE SHEET C301 MATCHEINE SHEET C302 9 LF 12" CMP INV. EL.= 24.00 -SD SD 8D SD SD- 5.7' 25.6' 25.6' 25.7' 25.8' 25.9' INLET TYPE E GR. EL.=25.00 INV. EL.= 22.20 IT:26.32 SAWCUT AND EXIST. PA 40 LF 12" CMP INLET TYPE E GR. EL.=25.00 INV. EL.= 22.20- m Z v Z INLET TYPE E C GR. EL.=25.70 INV. EL.= 22.20 TDC:26.52 SAWCUT AND MA EXIST. PAVEM 40 LF 12" CMP 26.7' INLET TYPE E GR. EL.=25.80 INV. EL.= 22.20 INLET TYPE E GR. EL.=26.00 INV. EL.= 22.20 40 LF 12" CMP SAWCUT AND EXIST. PA 7' 7% Lx25.7' 25.5' 23.68�sD SD sD sD- x23.6' \ x25.6' \ 25.9' 2 . 1 +24.9' 25.0 x24 4'' 4.3' ' �24+25.0' 27.48 26 LF 18" ADS PIPE ° x23.8 +� + ° +24.Ox +25.3' 24.2' ° ° •aC 26.10 , ° ° •D�. ° ° ° X 26.50' C °° ° ° ° ° ° ' 27r0 pov, 27.Ot1 ° • ° • : ° ° '8 • X 26.50 ° ° . • �•° . ° ° ° ° ° > X 26.2 , x24.9 0 26.10 " • R:<': 3.6% 3.6% 71 o° 9 LF 12" CMP INV. PROPOSED CONTROL 9 LF 12" CMP EL.= 24.00 N STRUCTURE (CS-2) INV. EL.= 25.00 I . 27.00 M TOPELI 9 LF 12" CMP INV. 5% 5% GRATE EL.- 27.00 LP INV. EL.= 25.00 ® ® 27 00 EL.= 25.00 ° LP ® 27.00 27.0 27.6 LP 1 24.7' 27.0 LP LP G LP 27.00 I 25. ' IV 27.0 I' P ° 25.00 � I I Irk ° 25.0 SAW C i° °0 26.50 I 0 10 °D M EXI N I M a. )� 0 0 + +25.5 27.s - 27.79 28.20 +25.3' F.F.E.=28.40 -2 .o' N 1C4 27.87 2.1% H F.F.E.=28.40 II II F.F.E.=28.40 '2 2% " 1 1% 27s7 10 2 - J J I 8.20 TDC:25. 2 LLJ Lv 2 BDC:25 80 25.00 b� I b� I H la- 40 LF 12" CMP STREET SAWCUT AND MATCH EXIST. PAVEMENT TDC:26.02 INLET TYPE E RI EV. - RIM ELEV. = 25.57' INLET TYPE E BDC:25.90 GR. EL.=25.00 78" RCP N INV. EL = 8. 5' RCP W INV. ELEV. = 18.62' GR. EL.=25.00 INV. EL.= 22.20 5' RCP W INV. ELEV - 7. ' 5' RCP E INV ELEV. = 18. 62' INV. EL.-_ 22.20 � 5' RCP E INV. Fl FV. T 5 ' �D 8D 8D 8D SD 8D 8D 8D 8D 3D 3D SD 3D 3D SD D 3D SD 3 SD SD SD SD SD 8D SD SD 8D SD 8D SD SD S - X25.00 ' 4.8 25.00 >x x24.5' :x24.5' e�a:e25.0 LEGEND 6 x 31.20 PROPOSED ELEVATION x 32.64' EXISTING ELEVATION FLOW DIRECTION ❑� PROPOSED DRAIN INLET PROPOSED MSE F TYPE E EL= 22.20 EL.= 22.PROPOSED DRAIN PIPE " AND MATCH PERIMETER BERM PAVEMENT N I M a. m 40 M +24. M .5' x2 2. 0 25.9' 26.3' 26.1 LF 12" CMP • SWA 0.218 27.0 A 26.50 27.00 27.07 _ 27.00 LP I I p LP, I A I I IF Z ° 25.7•5C27!5 BOT ELEV.=25d0 _ +25.5_ m _ _ _ _ x27.00 TOP ELEV. �26.00 -25.2 2 ° 4.3 °I I I I g o 26.50 I• n LP LP 27. x2 . ' m ® 24. LP.' 27.50 �7.5 A I 2® ° Z 25.70 �' ' ° m L I N N 25.6 E N ? A I 25. 1' 3 27.99 I 25.6' J ' 25. 1 27.7 =1 % H2%.2o F.F.E. = 28.40 25.1 _ __ 1 2 . o' F.F.E. = 28.40 -.1H 2 7.8 5% TDC:26. 2 2 • I I 8.20 BDC:26.60 A I, � b� I b� z a I COLo 1 14) N 25.8 F TYPE E EL.=25.00 EL.= 22.20 LET TYPE E Z. EL.=25.60 V. EL.= 22.20 VCUT AND MATCH 5T. PAVEMENT 27.00 26.50-11, 4.5 1 4,8'x 26.7' 26.8' 26.5 i.80\ I r ° ° 24 4C LF 12" CMP ° 27.50 7.5 ° ® � 07. 27.0 6.7 x2 8' LP I LP' ° PERIMETER BERM TOP EL.=27.00 A I 1 +26.0' A I °° 6° 27.I75 I �x26.4' 27.00+25.9�7'25. 0' � 27.00 ° � 2700x PERIMETER BEM B TOP EL.=27.01 Lp A I A 11 LP,,LP 26.10 LP _r 8.0 2® A I A 27.0 27.0 ° x .0' x 5' 26.5' 26.8' 26.6 24. 00 rn rn .e � � o oee, +26.9' 1 C:27.02 . ' 26.9' I �° 27.8 C:26.90 2111 I 28.29 I 28.30 I26.9' x26.9' �+ 27.9 TDC:26.82 HP 2% H 1 5% BDC:26.70 67 2� 1 % 5% 8.20 2% F.F.E.=28.40 +26.6' 25.5' F.F.E.=28.40 +2.r 26.6' °. 25.9 � 26.20 s N E x26.7' o • 2® J 127.0 27.0 28.00 5.2' x 4.7' LP x26.7' I LP .2' 28.0 28.2 28.00 INLET TYPE E P GR. EL.=26.20 7.2' 27.5' 71 ° 1 1. 25.0' INV. EL.= 22.20 ° I x25.6' INLET TYPE E x26 6' INLET TYPE E x25.7' + GR. EL.=25.70 04 �s 0 GR. EL.=25.50 �• INV. EL.= 22.20 +25.6' 6 INV. EL.= 22.20 -� 27.3' +26. ' �5'� 0.9% x 6.4 0.9%ry x26. ' p 5' jjj 26. 6' INLET TYPE E GR. EL.=25.80 INV. EL.= 22.20 `INLET TYPE E GR. EL.=26.10 z INV. EL.= 22.20 It 12" CMP ICUT AND MATCH 3L PAVEMENT INLET TYPE E GR. EL.=25.90 INV. EL.= 22.20 L rp +2 .6 x 5. 7 LF 12 CMP INV. ° ° ° °"26. o . x25. p X 27.55 V. x° • ° • x ° xPS. 1 0 ° • ° 2�.0 28.0°0 ° X,27.50 ° ° . -� x ,W27.00-° ' - 825.50 ° ° ' 26. 6' , 26.9' . ' X 27.10 ° ° 1 ' , x x a .:::; ° ° • 28.12 ° ° ° h 7 cv �y ° x 24.9' 27.2' ° 28.02 x 6. 6.30 26.00 25.7 x26.5' 25.50 x26.8' X�25.40 26.6' 7.5' 7 LF 12" CMP 7. N 25.4 x w 30 " CMP INV. ELEV. = 25.44' INV. EL.= 26.40 6 7, 'NE 7 LF 12" CMP 3RD STREET TDC:27.52 27.0 26• 7 LF 12" CMP INV. EL.= 25.45 INV. EL.= 26.50 40 LF 12" CMP BDC:27.40 SAWCUT AND MATCH EXIST. � PAVEMENT j GRAPHIC SCALE 20 0 10 20 40 80 ( IN FEET ) 1 inch = 20 ft. 01 -1 9-202 I 0EV S-0 F'_VNS -�EFF 0C M-E. NC Lv z C� T MATCH EXISTING GRADE i A T MATCH EXISTING GRADE BOT. EL. AS REQURED SCALE: 1:250 TYPICAL SECTION A -A I KI /C -#- T C` AIC1A/I MCC` w z _J w ROADWAY o ASPHALT PAVED ± 19' 15' SWALE 7' MATCH MATCH EXISTING BOT. EL. EXISTING GRADE AS GRADE REQUIRED PROP. 5' SIDEWALK PERIMETER BERM @ TOP EL. 27.00 (SEE DETAIL) PERIMETER /-BERM TYPICAL SECTION B-B - N.T.S. NEW LINES NE 5TH STREET LEGEND Z m Z v Z m 8" WY INV. E =21.1 8" WY INV. EL =20.90 8" WY INV. EL.=20.76 sv v v WV— ��, M M M M M —M M M M M 0 MEN° ° ° v °v ° ° v ° ° °O ' • v° C y,>: °a v ' ' v• vv ' ' vv ° °vv v ° •s:::: v ° v > v v v 4 8" E CENTRI S 136 LF SDR 26 ®0.4% SLOPE R DUCER CO #3 o > 8" 45' ELBOW INV. EL.=21.14 ® Co #2 ® 6 INV. EL.=21.39 4"x 8 8" 45' EL Val � 4"x 8" CO # 1 i ECCENTRIC INV. EL. 21.67 4" SERVICE, TYP. ECCENTRIC 1 .38 REDUCER REDUCER ILI CO #4 ° " 4 ELB ? CO #15 ° INV. EL.=21.02— 1 INV. EL.=21.69 � "WeE 8" 45' ELBOW 1 4"x 8" V. L1=21.02 " ECCENTRIC 8" 45' I EL OW REDUCER — �_ 8 WYE INV. EL.=21.5 I CO #16 INV. EL.=21.55 4"x 8" CO #5 ECCENTRIC INV. EL.=20.89 REDUCER I I CO #6 CO #17 INV. EL.=2 .68 INV. EL.=21.35 8" 45' ELBOW 1 CO #18 4"x 8" INV. EL.=21.29 I ECCENTRIC REDUCER 8" • I e /(n a• CO #7 INV. EL.=20.62 I INV. EL.=21.2 250 LF SDR 8" 45'1 0.4% SLOPE 1 _ _ _ _ 8" 45' ELB I 4"x 8" 4"x 8" I ECCENTRIC CCEI� EDUggI REDUCER e I I CO #8 #1 INV. EL.=20. INV =21 16 LONG SWEEP 90' \ LBOW s MATCHEINE SEE SHEET C402 ° I CO #2� 4"x 8" INV. EL =20.96 / ECCENTRIC REDUCER v I CO #21 INV. EL.=20.90 v/ a�1 � 8" 45' ELBOW 1 4"x 8" ECCENTRIC I REDUCER CO #22 INV. EL.=20.76 a 00- CO # 5 1 CO #24 INV. qL.=20.15 CO #23 INV. EL.=20.41 INV. EL_=20.72 8" 145' ELBOW CC S �— � 2 Lr-- � 26 -0--0?4T SL I 8" WYE INV. EL. 20.15 s v • ° ' ° v v v s °p v v RIM ELEV. = 25.57' 8" WYE INV. EL.=19.8 z CO #26 INV. EL.=19.89—� 8" WYE INV. EL.=20.49 CO #9 INV. EL 4"x 8" ECCENTRIC REDUCER CO #10 INV. EL.=20.24 -- 8" 45' ELBOW T 4"x 8" ECCENTRIC REDUCER CO #11 INV. EL.=20.10 CO #12 INV. EL.=19.76—, CO #13 INV. EL.=19.74 8" 45' ELBOW :j __j I NIAM v v s 8 vl V E . 20.62 5.71, �v dig �S 8" 45' ELBOW--'- INV. EL.=19.74 s ° s ° • sv v y s v y• ° v sv v ° v s v v CO #54 8" WYE INV. EL.=19.89 INV. EL.=19.74 z W- 8" LONG ELBOW 304 LF 0.4% SI cn 90' icn �6 U) z W U 0 8" INV. L.=20.1 c� z X 8" LONG SWE EP 0' ELBOW PROPOSED SEWEREINE QS PROPOSED SEWER MANHOLE PROPOSED SANITARY SEWER CEEANOUT PROPOSED DRAIN PIPE PROPOSED WATERLINE PROPOSED DRAIN INLET PROPOSED FIRE HYDRANT -0 PROPOSED WATER METER / 42" TAPPING SLEEVE WITH 2" TAPPING VALVE v° DIRECTIONAL DRILL 2" HDPE SEWER MAIN Ld o — — IFT STA ION N °p, j OP EL. 26.1 Vol . INV.= 2.6 0 OPEL. 26.1 W. INV.= 9.7 CO #53 co INV. EL.=20.07 0 J N NOTE: UNLESS OTHERWISE NOTED THE CONTRACTOR IS RESPONSIBLE FOR TEMPORARY DE —WATERING OF STRUCTURES, SEWER LINE, DRAINAGE PIPE AND WATER LINES. SCALE: 1:250 MATCHLINE SEE SHEET C401 8" E INV. EL.=21 z m N z v D m z C m 8" WYE INV. EL.=21 8" *E INV. EL.=21 8" M YE INV. EL.=: 8" MATCHLINE SEE SHEET C403 NE 4TH STREET NE 3RD STREET r GRAPHIC SCALE 20 0 10 20 40 80 ( IN FEET ) 1 inch = 20 ft. ;6.80 L SDR 26 1.4% SL PE I" LONG SWEEP 90' :LBOW 8" WYE INV. EL =20.70 U) 8" WYE INV. EL =20.84 fN m z rn w v D m z C Cn m U) 8" WYE INV. EL.=21.11 293 LF SDR 6 0.4% SLOPE 8" WYE cn INV. EL,=21.24 8" WYE INV. EL = 8" WYE INV. EL = D W 8" LONG SWEEP 0' ELBOW , LEGEND PROPOSED SEWERLINE SQ PROPOSED SEWER MANHOLE �- PROPOSED SANITARY SEWER CEEANOUT PROPOSED DRAIN PIPE PROPOSED WATERLINE PROPOSED DRAIN INLET PROPOSED FIRE HYDRANT -0 PROPOSED WATER METER NOTE: UNLESS OTHERWISE NOTED THE CONTRACTOR IS RESPONSIBLE FOR TEMPORARY DE —WATERING OF STRUCTURES, SEWER LINE, DRAINAGE PIPE AND WATER LINES. SCALE: 1:250 NE 5TH STREET CORP STOP 8" TEE 8" TEE LEGEND INSTALL 16"x 8" TAPPING bLLLVL AND G, 8" GATE VALVE VALVE INV. EL.= 24.00 (APPROX.) 3� WV ;wv. SD sD__sD s. sD_ /A A a— j /A A m /A - --p- ly w EXISTING WATERLINE BLOCK PROPOSED 8" 0 s s END CAP -/ —INSTALL FIRE HYDRANT PROPOSED WATERLINE WATERMAIN WATER METER - ASSEMBLY 8" TEE PROPOSED FIRE HYDRANT 16.39' 8" GATE VALVE —0 PROPOSED WATER METER 3: 20 o •�- a: I ' Cr Foc 1 PROPOSED SEWERLINE L EXISTING 16" WM­,," 1" P4LY 0 1" POLY 0 PROPOSED DRAIN PIPE F6 1 BLOCK 8"x 1 SADDLE w/ 1 0 Ly F� 1" PO 00 z CORP STOP PROPOSED DRAIN INLET KEY MA ....... ...... �1" ....... ....... m PROPOSED SEWER MANHOLE SCALE: 1:250 19 PROPOSED SANITARY SEWER CLFANOUT z m N z m z C m MATCHLINE SEE SHEET C402 GRAPHIC SCALE 20 0 10 20 40 80 IN FEET 1 inch= 20 ft. 0 1 —'9-20:2JI -tEVISED P ANS -3E9 1-tC MEETING W/ ill C601 NOTE: SEE INSET "A" ON SHEET C401 NOTE: UNLESS OTHERWISE NOTED THE CONTRACTOR IS RESPONSIBLE FOR TEMPORARY DE -WATERING OF STRUCTURES, SEWER LINE, DRAINAGE PIPE AND WATER LINES. S1 D I PDC MATCHL_INE SEE SHEET C401 —m MATCHLINE SEE SHEET C403 _T_ NIE 4T--H-STREET q 82 18' o CONNECT TO THE EXISTING OTHER S DIE OF THE LEGEND N ON THE 7Rl EV. — 10.32 STREET 18 " RCP N V. EL 78.45o 5' RCP W INV. ELEV. = 7.,5 13 5' RCP E INV. ELEV. 1�5 ' _ gD 8D D 8D 8D 8 8D 8D 8D 8D 8D 8D 8D 8D 8D 8D 8D 8D 8D 8 8D 8D 8D 8D 8D 9D 9D PD W EXISTING WATERLINE 82.10' 240.55' 8D 3 ° PROPOSED WATERLINE M M M ➢ r r ° $ r ➢ o ° > ° ° > ➢ .. ° B> ° > ° m . o> PROPOSED FIRE HYDRANT >➢ r P s r ° ➢MEN v 8 v ➢ r rl Cn ° ➢ N N ° -0 PROPOSED WATER METER Ali S S S PROPOSED SEWERLINE ® WATER METER TYP.� � � ➢ w PROPOSED DRAIN PIPE �*J1 .32 I I I 1. s6 WATER METER TYP. s 1 Y �e I 0 PROPOSED DRAIN INLET P KEY MA 6" WM ➢ ..�. SCALE: 1:250 1" POLY QS PROPOSED SEWER MANHOLE 2"x 1" SADDLE w/ 1" PROPOSED SANITARY CORP sroP SEWER CLEANOUT INSTALL 16" 8" TAPPING AND INV. L.= 24.00 (AF PROPOSED 8" WATER MAIN Nh 3KL) 51 Ktt I PROPOSED 8" WATER MAIN GRAPHIC SCALE 20 0 10 20 40 ( IN FEET ) 1 inch = 20 ft. 80 b EXISTING 6" WM i b Cn ' SAC DLE w/ 1" STOP Co fN cn U F 2"x 1 ' SADDLE w/ 1 " CORP STOP z �Cn W U Ct O C� Z U) (J) Cn NOTE: * SEE INSET "A" ON SHEET C402 NOTE: UNLESS OTHERWISE NOTED THE CONTRACTOR IS RESPONSIBLE FOR TEMPORARY DE —WATERING OF STRUCTURES, SEWER LINE, DRAINAGE PIPE AND WATER LINES. END CAP DIMENSIONS & QUANTITIES RISE R SPAN S X A B C E F G M N GRATE SIZES CONCRETE (CU. YDS.) SODDING (SO. YDS.) SINGLE PIPE DOUBLE PIPE TRIPLE PIPE QUAD. PIPE STANDARD WEIGHT PIPE EXTRA STRONG PIPE SINGLE PIPE DOUBLE PIPE TRIPLE PIPE QUAD. PIPE SINGLE PIPE DOUBLE PIPE TRIPLE PIPE QUAD. PIPE 12" 18" 2'-10' 2.36' 3.06' 5.42' 3.03' 5 1.50' 4.92' 7.75' 10.58' 13.42' 1.21' 0.68 1.04 1.41 1.77 8 9 11 12 14" 23" 3'-4" 2.44' 3.75' 6.19' 3.70' 6' 1.90' 5.38' 8.71' 12.04' 15.38' 1. 23' 0.76 1.19 1.63 2.05 9 10 12 13 19" 30" 4'-0" 2.62' 5.47' 8.09' 5.36' 8' 2,37' 6.04' 10.04' 14.04' 18.04' 1.27' 2.5" 3" 0,95 1.52 2.09 1 2.65 10 2 13 15 24" 38" 5'-0" 2.79' 7.18'0 9.97' 7.03' 10' 2,85' 6.79' 11.79' 16.79' 21.79' 1.31' 2.5" 3" 1.18 1.95 2.74 3.53 11 13 15 18 29" 45" 5'-11' 3.05' 8.90' 11.95' 8.70' 12' 3.19' 7,50' 13.42 9.33 25.25 1.38' 2.5" 3.5" 1.41 2.42 3.44 4.45 12 5 18 20 34 53" 7'-0" 3.22' 10.62' 13.84' 10.36' 13' 3.57' 8.25 15.25 22.25 29.25 1.42' 3" 3.5" 1.63 2.92 4.22 5.52 13 17 20 23 38" 60 ' 7'-10' 3.39' 1 1 .99' 15.38' 1 1 .70' 15' 3.95' 8.92 1 6. 55 24.58 32.42 1 .46' 3" 4" 1.83 3.36 4.89 6.41 14 18 21 25 43 68 8'-11' 3.56' 13.71' 17.27' 13.36' 17' 4.28' 9.67 18.58 27.50 36.42 1.50' 3" 4" 2.09 3.95 5.80 7.65 16 20 23 27 48" 76" 9'-11' 3.73' 15.43' 19.16' 15.03' 19' 4.59' 10.42' 20.33 30.25 40.17' 1.54' SPECIAL SPECIAL 2.37 4.54 6.73 8.92 17 21 26 30 53" 83" 10'-8' 3.9V 17.15' 21.06' 16.70' 20' 4.77' 11.08' 21.75 32.42 43.08 1.58' SPECIAL SPECIAL 2.61 5.09 7.56 10.03 18 23 27 32 58" 91 11'-8' 4.08' 18.87' 22.95' 18.36' 22' 5,01' 11.83' 23.50 35.17 46.83 1.63' SPECIAL SPECIAL 2.91 5.77 8.64 11.50 19 24 29 35 so BEVELED OR CONSTRUCTION LO SEE PE VARIES 2, ROUND CORNERS N JOINT PERMITTED PgVEMENTN T U SOD MOD I'CA 7/ON NgDETAILS,q GRATELo 17 S, 0 0 0 0 0 0C /, T 2' GRq TES 14 „ SPACED EliTO C. LL C om CONCRETE CONNECTOR CONSTRUCTION JOINT PERMITTED �Q PIPE i DITCH GRADE SADDLE I I z L 2' NOT LESS �I NR } I 10 ` o 0 0 o NO PIPE JOINT PERMITTED FASTENER PAID FOR AS UNLESS APPROVED BY THE EN INEER PIPE CULVERT E 3' 2' SOD SOD F (PIPE TO BE IN LUDED UNDER UNIT PRICE FOR MITERED END SECTION) CONCRETE SLAB, 3" THICK, REINFORCED N WITH WWF 6X6-W1.4XW1.4 *SLOPE: TO MAJOR AXIS FOR PIPES 24" X 38" AND SMALLER. 2:1 FOR PIPES 29"!45" AND LARGER. Lo I TOP VIEW -SINGLE PIPE SECTION SIDE DRAIN MITERED END SECTION 2'-4" 2 1 „ 11" 2„ O O O O O O �� O O _ O O PIPE 00 O 0 0 O �I c 0 O O O O O O O O -DO O n= N � 2'-4" �� _ Icv w 00 1„ 1„ =0 12 2" 12 L` PLAN 0 o APPROX. WEIGHT 235 LBS. o 2'-4" z z 3'-4" 3" x � 5T w o m z ow 2'-0" W - 1 � GRATE � o �-- � PIPE � cCT v x w 2" CL. Ud i)(p QI Q Ln ro - - cn aU > u I Cw) cn N 18 Q m m BOLTS EYE cmn INDEX SEE t L 00 201 f #4 BARS @ 12" CTRS. 12"0 WEEPHOLE STRAIGHT BARS 2"X 4" SECTION W/ROCK/FILTER RETICULINE BARS 1 1"X16" FABRIC BANDS 2"X 4" RECOMMENDED MAXIMUM PIPE SIZE: APPROX. WEIGHT 104 LBS. 2'-0" WALL-18" PIPE NOTES: 1) STEEL GRATES ARE REQUIRED ON INLETS 2) ALL INLETS WILL BE CAST TO PROVIDE A 18" WITH TRAVERSABLE SLOTS AND ON INLETS SUMP BELOW LOWEST CULVERT INVERT WHERE BICYCLE TRAFFIC IS ANTICIPATED. PRE -CAST TYPE 'E' CATCH BASIN 0DR nITc nIF ��nn IN 1 1/2" TYPE SP 9.5 ASPHALTIC CONCRETE 12" STABILIZED SUB -GRADE FBV OF 75 PSI COMPACTED TO 98% MAX. DENSITY PER AASHTO T-180 METHOD. SUB -GRADE SHALL MEET LBR 40 PAVEMENT SECTION 8" LIMESTONE OR COQUINA BASE COMPACTED TO 98% MAX. DENSITY PER AASHTO T-180 METHOD. BASE SHALL MEET LBR 100 ISOMETRIC VIEW JOINTS WOVEN OR NON -WOVEN FILTER 12' 12 FABRIC TYPE D-3 (SEE INDEX MIN. MIN. 199) SECURING DEVICE ELLIPTICAL PIPE JOINTS ROUND PIPE PIPE SECTIONS COST OF FILTER FABRIC JACKET TO BE INCLUDED IN COST OF PIPE CULVERTS FOR ALL PIPE TYPES FILTER FABRIC JACKET _.._ _ uA ��� T 09/22 FL CD#6 N.T.S. NEWLINES TYPICAL WHEELSTOP DETAIL -#5X18" -0 PAVING N OR NON -WOVEN FILTER IC SECURING DEVICE 09/22 IFL DR#14 09/22 IFL DR#18 HANDICAPPED SYMBOL 1/8" ALUMINUM PANEL SCREEN PRINT SYMBOL COLORS SELECTED SELECTED PER OKEECHOBEE COUNTY PARKING CODE FENCE POST (SPACING 8'-0" CE TO CL ) FABRIC TO BE SECURED TO POST WITH METAL FASTENERS & REINFORCEMENT BETWEEN FASTENER AND FABRIC. SILT ACCUMULATION - GRADE DIG 6" DEEP TRENCH, -/ BURY BOTTOM FLAP, TAMP IN PLACE. IAL WIRE FENCE BEHIND FABRIC FOR "SUPER" SILT FENCE. OPTIONAL WIRE FENCE BEHIND FABRIC FOR "SUPER" SILT FENCE. z 0 N 0 N NOTES: 1. 1. FENCE POSTS SHALL BE SPACED 8 FEET CENTER -TO -CENTER OR CLOSER. THEY SHALL EXTEND AT LEAST 2 FEET INTO THE GROUND AND EXTEND AT LEAST 2 FEET ABOVE GROUND (FIG. 23-2). POSTS SHALL BE CONSTRUCTED OF HARDWOOD WITH A MINIMUM DIAMETER THICKNESS OF 1 1/2 INCHES 2. "SUPER" SILT FENCE -A METAL FENCE WITH 6 INCH OR SMALLER MESH OPENINGS AND AT LEAST 2 FEET HIGH MAY BE UTILIZED, FASTENED TO THE FENCE POSTS, TO PROVIDE REINFORCEMENT AND SUPPORT TO THE GEOTEXTILE FABRIC. POSTS MAY BE SPACED LESS THAN 8 FEET ON CENTER AND MAY BE CONSTRUCTED OF HEAVIER WOOD OR METAL AS NEEDED TO WITHSTAND HEAVIER SEDIMENT LOADING. THIS PRACTICE IS APPROPRIATE WHERE SPACE FOR OTHER PRACTICES IS LIMITED AND HEAVY SEDIMENT LOADING IS EXPECTED, "SUPER" SILT FENCE IS NOT TO BE USED IN PLACE OF PROPERLY DESIGNED DIVERSIONS (PG. 15-1) WHICH MAY BE NEEDED TO CONTROL SURFACE RUNOFF RATES AND VELOCITIES. 3. A GEOTEXTILE FABRIC, RECOMMENDED FOR SUCH USE BY MANUFACTURER, SHALL BE BURIED AT LEAST 6 INCHES DEEP IN THE GROUND. THE FABRIC SHALL EXTEND AT LEAST 2 FEET ABOVE THE GROUND. THE FABRIC MUST BE SECURELY FASTENED TO THE POSTS USING A SYSTEM CONSISTING OF METAL FASTENERS (NAILS OR STAPLES) AND A HIGH STRENGTH REINFORCEMENT MATERIAL (NYLON WEBBING, GROMMETS, WASHERS ETC.) PLACED BETWEEN THE FASTENERS AND THE GEOTEXTILE FABRIC. THE FASTENING SYSTEM SHALL RESIST TEARING AWAY FROM THE POST. THE FABRIC SHALL INCORPORATE A DRAWSTRING IN THE TOP PORTION OF THE FENCE FOR ADDED STRENGTH. 4. SEDIMENT SHALL BE REMOVED FROM THE UPSTREAM FACE OF THE BARRIER WHEN IT HAS REACHED A DEPTH OF 1/2 THE BARRIER HEIGHT. 5. REPAIR OR REPLACE BARRIER (FABRIC, POSTS, BALES ETC.) WHEN DAMAGED. 6. BARRIERS SHALL BE INSPECTED DAILY FOR SIGNS OF DETERIORATION AND SEDIMENT REMOVAL. 1 '-0" PARKING BY DISABLED PERMIT ONLI VAN ACCESSIBLE /$250 FINE SILT FENCE DETAIL C(i] 2" SO. ALUMINUM POST FINISH AS PER SPECIFICATIONS FINISHED GRADE EARTH 1=1 II II � I1 I-1 I ° '` a . =1 (_° CONCRETE FOOTING EDGE OF PAVEMENT HANDICAPPED PARKING SIGN Ln FL SE#1 FINISHED GRADE SEE NOTE NO. 5 zQ SPRING n INITIAL BACKFILL 0-'w LINE \ o Q mg OF HAUNCHING PIPE BEDDING 6" MIN. IF REQUIRED FOUNDATION (MAY NOT BE REQUIRED) 1/4 R 1/4"R 1/2„ (TYP.) D/4 ° D 1 /2" PRE -MOLDED 3/1 6" SAW CUT JOINT EXPANSION JOINT MATERIAL MAYBE SUBSTITUTED EXPANSION JOINTS CONTRACTION JOINTS SEE PLANS FOR WIDTH SLOPE PER 3,000 PSI CLASS 1 CROSS CONCRETE SECTIONS 6" - 2 % NOTES: 0 1. IN CERTAIN SOIL CONDITIONS A FOUNDATION MAY BE REQUIRED. _---COMPACT SUBGRADE TO 95% OF THE MAXIMUM DENSITY AS 2. BEDDING IS REQUIRED PRIMARILY TO BRING THE TRENCH BOTTOM UP TO DETERMINED BY AASHTO T-99 GRADE. BEDDING MATERIALS SHALL PROVIDE A UNIFORM AND ADEQUATE LONGITUDINAL SUPPORT UNDER THE PIPE. 3. HAUNCHING MATERIAL SHALL BE HAND PLACED TO THE SPRINGLINE OF THE PIPE. MATERIAL SHALL BE CONSOLIDATED UNDER THE PIPE AND HAND NOTES: TAMPED TO PROVIDE ADEQUATE SIDE SUPPORT. 1. PROVIDE EXPANSION JOINTS 20' CENTER TO CENTER, AT PC & PT OF 4. INITIAL BACKFILL MATERIAL SHALL BE HAND PLACED TO 12" ABOVE THE TOP CURVES, JUNCTIONS OF EXISTING & NEW SIDEWALKS, AND WHERE SIDEWALK OF PIPE. THE SOIL SHALL BE COMPACTED. ABUTS CURBS, DRIVEWAYS & SIMILAR STRUCTURES. 5. BACKFILL SHALL BE COMPACTED TO 100% OF MAX. DENSITY AS PER 2. PROVIDE CONTRACTION JOINTS 5' CENTER TO CENTER. AASHTO T-99, TO A POINT 30" BELOW PROPOSED PROFILE GRADE OR EXISTING GRADE. THE FINAL 30" OF BACKFILL SHALL BE COMPACTED TO 3. SOD SHALL BE PLACED BELOW EDGE OF SIDEWALK TO ALLOW DRAINAGE. 98% OF MAX. DENSITY AS PER AASHTO T-180. 4. SIDEWALK WITH 6"X6" NO. 10 WELDED WIRE MESH THROUGHOUT THIS 6. DENSITY TEST SHALL BE PREFORMED AT AREAS DETERMINED BY THE PROJECT. UTILITIES ENGINEER OR PERMIT AGENCY HAVING JURISDICTION, AT THE CONTRACTOR'S EXPENSE. BACKFILLING REQUIREMENTS 09/22 FL DR 12 TYPICAL SIDEWALK 09/22 FL C8 N.T.S. NEWLINES N.T.S. NEWLINES FINISHED GRADE A DENSITY TEST SHALL BE PERFORMED BETWEEN STRUCTURES AT THE FOLLOWING LOCATIONS: II III BEGIN TESTING IN THE FIRST FOOT =I��III�II III III AND THEN EVERY 2 FEET TO WITHIN 2 FEET OF SUBGRADE � BACKFILL SHALL BE PLACED IN 12" MAX. I 11 III- LAYERS, EACH LAYER TO BE MECHANICALLY IIII _ I TAMPED TO A MINIMUM 100% OF MAX. IIII- w Q II DENSITY AS DETERMINED BY AASHTO z z METHOD T-99 FOR NON -FLEXIBLE PIPE -III J o Lj w o o (RCP, DIP) AND 98% FOR FLEXIBLE PIPE. ICI > a_ < [ifJ Q =a �,cnm Q z< 12" MAX. 12" MAX. o w o o w > zmz- Qw Q O O O O O Ovo o o < Q woJ Qz v_ 6' 5' 6' w 0000 0EfE 00 O 0000000< N 00000 o�m 1--z wQ m� 000 O Ljj x Q � � r oo� >m /:12 \2MA O O O O O Qa� 00 000 000 �o� z NE- 0 0 0 0 HANDICAPPED SIGN 0 O O 0 O 0 z J w INVERT 00E g�cc OOO Imo WHEEL STOP HANDICAP0111dI I I -I I I II I I PAVEMENT II I II o STRIPING PER FDOT INDEX 17346 HAND PLACED SELECT MATERIAL (MAXIMUM 6" LAYERS) COMPACTED WITH ck:�4 MECHANICAL TAMPERS NOTE: HANDICAPPED SYMBOL IF PIPE IS NOT UNDER PROPOSED PAVEMENT, BACKFILL SHALL BE COMPACTED TO A FIRMNESS APPROXIMATELY EQUAL TO THAT OF THE 6" STRIPES (TYP.) SOIL ADJACENT TO THE PIPE TRENCH. 5'0" 1 2'0" 09/22 FL DR 8 TYPICAL TRENCH DETAIL 17'0" N.T.S. NEWLINES HANDICAPPED PARKING NOTE: ALL PAVED PARKING STALLS ARE TO BE DOUBLE STRIPED. HANDICAPPED PARKING SIGNAGE/STRIPING DETAIL EDGE OF PAVEMENT NEW PAV'MT. & BASE 36" X 36" (TYP) I x zQ �� 6' MIN `J`' z 000 1 12' MAX Q 24" WHITE 6' MIN STOP BAR 12' MAX STOP SIGN LOCATION DETAIL 6" 3,000 PSI CONCRETE (FIBER REINFORCED) 12" STABILIZED SUB -GRADE FBV OF OF 75 PSI COMPACTED TO 98% MAX. DENSITY PER AASHTO T-180 METHOD. SUB -GRADE SHALL MEET LBR 40 2' EXIST. PAV'MT.J ALL JOINTS BETWEEN EXISTING AND NEW PAVING SHALL BE SEALED BY MILL 2" DEEP, PAVE TOP COURSE OF THE CONTRACTOR. 2" COMPACTED THICKNESS, MIX-5 �2 AFTER2" MILLING 2 3 MONTHS (MIN) III-III-III U ��o���yoQ�o�Q-III-I 1 1- 2,5" COMPACTED BASE -I I I -I I COURSE OF PLANT MIXED IIII-III-III 000�do��o�go-III-III- BIT. STAB. BASE COURSE 00 oo (MIX 1-2). CONSTRUCTED A IN LAYERS OF NOT MORE IIII-ITHAN TWO INCHES 09/22 FL CD 13 -III-III \--I 1I-I I -III COMPACTED THICKNESS. N.T.S. INEWLINES (5" PRIOR TO MILLING) UNDISTURBED 6" COMPACTED DENSE SAW CUT EXIST. GRADED AGGREGATE PAV' MT. ROAD PAVEMENT REPAIR DETAIL 03/22 cN 21 N.T.S. NEWLINE`. -IIIIIIII - & BASE I 09/22 FL CD 7 SAW CUT DETAIL 09/22 FL CD 1 N.T.S. NEWLINES N.T.S. NEWLINES 2' 2' WHITE THERMOPLASTIC -�,f PAINT 6" WHITE STRIPE 20' OVERALL STALL LENGTH 6' WHEEL STOP OR FACE OF CURB 6" WHITE STRIPE EDGE OF PAVEMENT OR BACK OF CURB * FOR PAVED AREAS 09/22 FL CD 9 CONCRETE PAVEMENT 09/22 FL CD#17 09/22 FL CD 4 N.T.S. NEWLINES S ECTI 0 N N.T.S. NEWLINES TYPICAL PARKING STALL N.T.S. NEWLINES CROSSWALK STRIPING DETAIL 01/22 cD 35 01-19-20231 REVISED PLANS PER TRC MEETING SLD PDC THIS DOCUMENT, TOGETHER WITH THE CONCEPTS AND DESIGNS PRESENTED HEREIN, AS AN INSTRUMENT OF SERVICE, IS INTENDED ONLY FOR THE SPECIFIC PURPOSE AND CLIENT FOR WHICH IT WAS PREPARED. REUSE OF AND IMPROPER RELIANCE ON THIS DOCUMENT WITHOUT WRITTEN AUTHORIZATION AND ADOPTION BY STEVEN L. DOBBS, P.E., SHALL BE WITHOUT LIABILITY TO NEWLINES ENGINEERING do SURVEY AND STEVEN L. DOBBS ENGINEERING, LLC. ALL CONCRETE TO DE CLASS B' 3500 PSI (UNLESS OTHERWISE NOTED) MINOR SUBDIVISION PLAN DETAILS - 1 GLENWOOD PARK LYING IN SEC 15, TOWNSHIP 37 SOUTH, RANGE 35 EAST, OKEECHOBEE CITY, FLORIDA NEWLII�ES IDI AND CONSHI I AIN I b LLC cc STEVEN L. DOBBS, P.E. PROJECT NO. FL22024 DRAWN BY J M SCALE AS SHOWN DATE 2023-03-24 FLORIDA CERTIFICATE OF AUTHORIZATION NO. 00029206 DATE STEVEN L. DOBBS ENGINEERING, LLC SHEET J62 JAKES WAY OKEECHOBEE, FL 34974, PHONE (863) 824-7644 C600 OF 19 � -PROPERTY LINE CHECK VALVE (RESIDENTIAL) METER BOX VALVE BOXY ` PRESSURE TEST LIMIT PAVEMENT ISOLATION VALVE W/ VALVE BOX AND METER BY OKEECHOBEE UTILITY AUTHORITY TYPICAL ALL SERVICES Q 24" 24" z PROPERTY MIN. MIN. Q LINE (TYP) ANGLE STOP --f f-A, METER (LOCKING TYPE o 3/4 " OR 1" MIN. SERVICE z ISOLATION VALVE � LINE POLYETHYLENE TUBING 0 z SHORT SERVICES ONLY z x 7� w WATER o w N MAIN rD O 0" OR 45' ANGL CENTER & SEAL ENDS (TYP)-- CORP STOP FOR INSTALLATION OF SERVICES UNDER EXISTING / OR PROPOSED PAVEMENT AND RIGHTS OF WAY, INSTALL GALVANIZED STEEL (2" MIN., 4" MAX.) SCH. 40 PVC OR HDPE CASING DOUBLE STRAP SADDLE. (CORPORATION STOP IS REQUIRED) NOTES: 1. SUCCESSIVE TAPS INTO THE WATER MAIN SHALL BE SPACED A MINIMUM OF 18" APART. TAPS SPACED BETWEEN 18" TO 48" SHALL BE OFFSET TO EACH SIDE OF THE MAIN, OR OFFSET 45°. 2. METER BOX SHALL BE SET TO CONFORM TO FINISHED GRADE ADJACENT TO PROPERTY LINE. METER BOX SHALL NOT BE PLACED IN SIDEWALK OR DRIVEWAY AREAS. SERVICE LINES SHALL NOT BE PLACED UNDER DRIVEWAYS. 3. SERVICE CONNECTION TUBING TO BE POLYETHYLENE AND MAXIMUM LENGTH OF 100'. 4. ALL 5/8 " & 1" METERS REQUIRE A 3/4 " & 1" LOCKING ANGLE METER VALVE RESPECTIVELY. 5. AFTER METER INSTALLATION, INSTALL LINE VALVE IN CUSTOMER SERVICE LINE. 6. DIMENSION "A" - 7" (5/8" X 3/4" METER) = 8" (1" METER) 7. CONTRACTOR TO PROVIDE & INSTALL ENTIRE WATER SERVICE UP TO ANGLE STOP INCLUDING METER BOX. 8. QUA TO PROVIDE AND INSTALL METER. 9. QUA TO INSTALL IN -LINE DUAL CHECK VALVE (RESIDENTIAL). 10. QUA TO INSTALL ISOLATION VALVE & BOX ON CUSTOMER SIDE OF METER INSTALLATION. * 36" MIN. IN STATE ROAD R/W & UNDER ASPHALT TYPICAL SERVICE CONNECTION (UNDERGROUND) OF 5/8" x 3/4" OR 1 " METER 3/4 " SERV ANGLE STOP (TYP) METER SINGLE SERVICE CHECK VALVE LINE (TYP) CORP STOP SERVICE LINE NCH DOUBLE SERVICE RVICE "Y" E LINE VE (TYP) 'P) z a w Q DOUBLE STRAP TAPPING SADDLE - AWWA (TYP) z Q w w Q NOTES: 1. AUTHORIZED SERVICE LINE MATERIAL SHALL BE POLYETHYLENE TUBING. 2. MULTIPLE SERVICE/METER INSTALLATIONS OF MORE THAN 4 METERS PER SERVICE AND SERVICE LINES LARGER THAN 2" IN DIAMETER SHALL BE HANDLED ON AN INDIVIDUAL BASIS. 3. NO FITTINGS BETWEEN CORP. STOP & ANGLE VALVE OR CORP. STOP & "Y" BRANCH FOR MULTIMETER INSTALLATIONS. TYPICAL SERVICE FOR MULTIPLE SERVICES (TWO OR 10/15 1 QUA #1 MORE) NI T C I NF\NI INFC QUA ( (-,K IT A r'Tno (lI IA MAIN NOTES 1. WATER MAIN TO BE PRESSURE TESTED AND DISINFECTED ACCORDING TO FDEP REGULATIONS, AWWA STANDARDS AND QUA REQUIREMENTS. 2. BACTERIOLOGICAL TESTING IS TO BE PERFORMED BY CONTRACTOR WITH PRIOR NOTIFICATION OF TESTING TO QUA PERSONNEL. 3. DO NOT REMOVE TEMPORARY CONNECTION UNTIL ALL TESTING HAS BEEN COMPLETED. 4. PROVIDE ALL NECESSARY THRUST BLOCKS OR OTHER RESTRAINTS. 5. FILLING AND FLUSHING LOCATIONS SHALL BE DETERMINED BY THE CONTRACTOR AND WITH APPROVAL OF ENGINEER AND/OR QUA. 6. MAIN LINE VALVE TO BE OPENED BY QUA PERSONNEL ONLY AND OPENED FOR CANNON FLUSHING OF NEW PIPING SYSTEM. FILLING, DISINFECTING AND TESTING DETAILS SMOOTH, UNTHREADED 0.5" HOSE BIB FOR BACTERIA SAMPLES __IV I VALVE NOTES 12" MINIMUM 2" PVC SCH 80 OR BRASS FORMULA FOR ESTIMATING RATE OF DISCHARGE Q = 2.83 d2SX WHERE: Q = DISCHARGE IN GALLONS PER MINUTE d = INSIDE DIAMETER OF DISCHARGE PIPE d, Sx, Sy = MEASURED IN INCHES 1. REFERENCE, AWWA C651. 2. THIS DETAIL APPLIES TO PIPES UP TO AND INCLUDING 8" DIAMETER. LARGER SIZES SHALL BE HANDLED ON A CASE BY CASE BASIS. 3. PIGGING OF LINES IS AN ACCEPTABLE METHOD OF CLEANING. 4. ABOVE GROUND PIPING TO BE REMOVED UPON COMPLETION OF TESTING. 10/15 1QUA #10 TOP OF GRATE ELEV. 26.50' TOP OF GRATE ELEV. 27.00' 5' NON- 5' NON - PERFORATED PERFORATED 4" ADS N-12 y 4" ADS N-12 y 1 BOTTOM OF DRY BOTTOM OF DRY DETENTION=EL. 24.00 DETENTION=EL. 25.00 3" DIA PER -CAST BLEEDER ORIFICE 3" DIA PER -CAST BLEEDER ORIFICE DISCHARGE EL=23.00 \`I poll DISCHARGE EL=24.00 \`I PIPE -IIIIIIIIIIIIII PIPE L-------- I L-------- I �4" PERFORATED ADS N-12 PIPE INV.=23.0 PEA GRAVEL #57 STONE CONTROL STRUCTURE CS-1 TYPE "C" INLET (MODIFIED) 103/23 N.T.S. TOP OF DEPRESSED CURB PAVEMENT V (MIN) WIDTH OF APRON SURFACE 1/2" 4 1/2 w z d a J N 4 4 d 44 fl d H � 5' 3' ±3' w IL CONSTRUCT PERIMETER SECTION A - A �4" PERFORATED ADS N-12 PIPE INV.=24.0 PEA GRAVEL #57 STONE NE FITCONTROL STRUCTURE CS-2 TYPE "C" INLET (MODIFIED) v TOP OF CURB 1' (MIN) p 6) 4 p a Q a � D � n D BERM @ TOP EL. 27.0 1/2" BITUMINOUS PREMOLDED CLASS "B" CONCRETE MATCH EXISTING GRADE EXPANSION JOINT 4500 P.S.I. AT 28 DAYS D 6" 90" ELBOW AT PROPERTY LINE WIDTH OF DRIVEWAY 8" 6" TEE MATCH EXISTING �1 GRADE 3 3 NOTE: SOD LIMITS OF SECTION PERIMETER BERM/SECTION - x 1 Q Y J d d X a � A a Q A N w d 4 w w p p p4 J CD WWW`WWWW.WWWW`WWW`WWW .WwW.WwW.W.W.y.WwW.WwW w w CD wQ w DEPRESSED CURB AS WIDE AS APRON w L'i 1 1 � DEPRESSED CURB AT DRIVEWAY WITH GRASS 03, w w 3 W D v EXISTING 6" WM o rn U 3 v °C 6"x6 TAPPING SLEEVE WITH 6" TAPPING D �v CONNECTION WITH EXISTING 6" WATERMAIN WATER NOTES: 1. SAMPLE POINT SHOULD BE ON A SERVICE LINE OR FIRE HYDRANT IF POSSIBLE. 2. SAMPLE POINT TO BE REMOVED BY CONTRACTOR AFTER PROJECT IS ACCEPTED. 03/23 1 SAMPLING POINT (ON MAIN I 0/15 1 QUA #9A FLUSHING DETAILS i Ni T C AIC\All MCC co 8" 6" TR=% 11 PAVEMENT R=3/4" a ° , NOTE: 3,000 PSI CONCRETE AT 28 DAYS. TYPE "D" CURB D ETAI L 09!C2 FL \A/°# 10/15 1 QUA #7 �EWLINES ALL CONCRETE TO BE CLASS B' 3500 PSI (UNLESS OTHERWISE NOTED) MINOR SUBDIVISION PLAN DETAILS - 2 GLENWOOD PARK LYING IN SEC 15, TOWNSHIP 37 SOUTH, RANGE 35 EAST, OKEECHOBEE CITY, FLORIDA 4P1ANDECONSML1I IN I bELLC Cc STEVEN L. DOBBS, P.E. PROJECT NO. FL22024 DRAWN BY J M SCALE AS S HOW N 01-19-20231 REVISED PLANS PER TRC MEETING I SLD PDC DATE 2023-03-24 THIS DOCUMENT, TOGETHER WITH THE CONCEPTS AND DESIGNS PRESENTED HEREIN, AS AN INSTRUMENT OF SERVICE, FLORIDA CERTIFICATE OF AUTHORIZATION NO. 00029206 DATE IS INTENDED ONLY FOR THE SPECIFIC PURPOSE AND CLIENT FOR WHICH IT WAS PREPARED. REUSE OF AND STEVEN L. DOBBS ENGINEERING, LLC SHEET IMPROPER RELIANCE ON THIS DOCUMENT WITHOUT WRITTEN AUTHORIZATION AND ADOPTION BY STEVEN L. DOBBS, P.E., SHALL BE WITHOUT LIABILITY TO NEWLINES ENGINEERING do SURVEY AND STEVEN L. DOBBS ENGINEERING, LLC. 1062 JAKES WAY OKEECHOBEE, FL 34974, PHONE (863) 824-7644 C601 OF 19 18" CMP INV. ELEV. = 23.25 FIRE HYDRANT USE ANCHOR COUPLING Oo MECHANICAL JOINT TEE VARIES PIPING TO BE MECHANICAL JOINT RESTRAINED IE 18" MAX. 4 1/2 " PUMPER NOZZLE FACING AS DIRECTED, AND TWO 2-1/2" HOSE NOZZLES. o Q GROUND OR z Q PAVEMENT SURFACE C° N � FINISHED GRADE VALVE SETTING (SEE DETAIL) z Q 18 " o co UNDISTURBED 6" R.S.G.V. SOIL nn 6" D.I.P. OR PVC C-900 nn Rer 5 1 /4 " VALVE OPENING UNDISTURBED SOIL 1. HYDRANT SHALL BE INSTALLED PLUMB AND TRUE. 2. THE MODEL COLOR TO BE SAFETY YELLOW, HYDRANT SHALL BE PER QUA REQUIREMENTS. 3. VALVE SHALL BE PLACED ADJACENT TO MAIN, TIED TO TEE. 4. ANCHOR TEES ARE PERMITTED. 5. ALL HYDRANTS SHALL BE TEE'D OFF MAINS. 6. HYDRANTS SHALL NOT BE PLACED IN SIDEWALKS, ROADWAYS OR BIKEPATHS. 7. MEGALUGS ON ALL FITTINGS. 8. HYDRANTS SHALL BE BAGGED UNTIL SYSTEM IS PLACED IN SERVICE. LOCATION OF PUBLIC WATER SYSTEM MAINS IN ACCORDANCE WITH F.A.C. RULE 62-555.314 OTHER PIPES HORIZONTAL SEPERATION CROSSING (1) JOINT SPACING @ CROSSINGS (FULL JOINT CENTERED) WATER MAIN ALTERNATE 3 FT. WATER MAIN 12 INCHES IS THE MINIMUM STORM SEWER, 11 MINIMUM EXCEPT FOR WATER MAIN STORMWATER FORCE MAIN, STORM SEWER, THEN 6 RECLAIM WATER (2) 3 FT. INCHES IS THE MINIMUM MINIMUM AND 12 INCHES IS if PREFERRED WATER MAIN ALTERNATE 3 FT. WATER MAIN11 MINIMUM VACUUM SANITARY SEWER 10 FT. PREFERRED 12 INCHES PREFERRED 6 INCHES MINIMUM WATER MAIN 3 FT. MINIMUM WATER MAIN ALTERNATE 6 FT. GRAVITY OR PRESSURE SANITARY SEWER, SANITARY SEWER FORCEMAIN RECLAIM WATER (4) WATER MAIN 10 FT. PREFERRED 116 FT. MINIMUM 12 INCHES IS THE MINIMUM EXCEPT FOR GRAVITY SEWER, THEN 6 INCHES IS THE MINIMUM AND 12 INCHES IS PREFERRED MINIMUM WATER MAIN ON -SITE SEWAGE 10 FT. - - - --- TREATMENT & DISPOSAL MINIMUM FAC RULE 62-555.314 NOTES: 1. WATERMAIN TO CROSS OVER CONFLICT PIPES WHEREVER POSSIBLE, MAINTAINING 30 INCHES COVER AND 6 INCHES SEPARATION AS MINIMUMS. WHEN WATER MAIN MUST BE BELOW OTHER PIPE, THE MIN. SEPARATION IS 12 INCHES. 2. RECLAIMED WATER REGULATED UNDER PART III OF CHAPER 62-610, F.A.C. 3, 3 FT FOR GRAVITY SANITARY SEWER WHERE THE BOTTOM OF THE WATER IS LAID AT LEAST 6 INCHES ABOVE THE TOP OF THE GRAVITY SANITARY SEWER. 4, RECLAIMED WATER NOT REGULATED UNDER PART III OF CHAPTER 62-610, F.A.C. NOTES: A. THESE METHODS ARE TO BE USED WHEN INSUFFICIENT COVER EXISTS TO ALLOW PRESSURE PIPE TO CROSS ABOVE CONFLICT PIPE WITH 6 INCHES VERTICAL SEPARATION AND MAINTAIN 30 INCHES COVER TO FINISHED GRADE. B. FITTINGS SHALL BE RESTRAINED WITH MECHANICAL RESTRAINTS (MEGALUG). IN ACCORDANCE WITH OUA STANDARD DETAILS. C. THE DEFLECTION TYPE CROSSING IS PREFERRED. D. DO NOT EXCEED 75% OF MANUFACTURERS RECOMMENDED MAXIMUM JOINT DEFLECTION. E. MECHANICALLY RESTRAIN ALL FITTINGS. AS PER MANUFACTURERS RECOMMENDATION AND OUA STANDARD DETAILS. WATER MAIN - SANITARY SEWER CONFLICT -24"� N PLAN CAST IRON COVER MARKED "WATER", "SEWER" OR "FIRE" TOP OF PAVEMENT 4" 5-1/4" C.I. ADJUSTABLE VALVE BOX (INSIDE SCREW TYPE) D/I OR C-900 P.V.C. SQUARE NUT MECHANICAL JOINT VALVE CONCRETE COLLAR POUR CONCRETE COLLAR TO GRADE IN SODDED AREAS JURISDICTIONAL LINE (IF APPLICABLE) SILT SCREEN RESTORATION & GRASSING PAYMENT LIMITS 12" BENCH WIDT� 12" 12" 12" AN. MAX. I PIPE O.D. MAX. UNDISTURBED EARTH BACKFILLED & COMPACTED TO 98% MAX. DENSITY AT +/- 2% OF OPTIMUM MOISTURE DETERMINED BY MODIFIED PROCTOR TEST AASHTO T-180/ASTM D 1557, IN 12" LOOSE THICKNESS LIFTS. BACKFILLED & COMPACTED TO 98% MAX. DENSITY AT +/- 2% OF OPTIMUM MOISTURE DETERMINED BY MODIFIED PROCTOR TEST AASHTO T-180/ASTM D 1557, IN 6" LOOSE THICKNESS LIFTS. NOTES: 1. BACKFILL MATERIALS SHALL CONSIST OF CLEAN EARTH FILL COMPRISED OF SAND, SAND AND CLAY, GRAVEL, CRUSHED ROCK OR OTHER MATERIALS FROM GROUPS A-1, A-2 OR A-3, AASHTO CLASSIFICATION, FREE FROM ORGANIC MATTER AND VEGETATION, DEBRIS, LARGE CLODS OF EARTH OR STONES. UNSUITABLE IN -SITU MATERIALS SUCH AS MUCK, DEBRIS, LARGE ROCKS AND ROOTS SHALL BE REMOVED AND DISPOSED OF BY THE CONTRACTOR. 2. THE PIPE SHALL BE FULLY SUPPORTED ALONG ENTIRE LENGTH. x 3. THE PIPE TRENCH SHALL REMAIN DRY DURING PIPE LAYING OPERATIONS. 7N 4. ALL TRENCH WORK SHALL CONFORM TO LATEST STANDARDS AS SET FORTH BY THE FLORIDA TRENCH SAFETY ACT AND OR OSHA. CD CO 5. FOUR INCH WIDE DETECTABLE TAPE SHALL BE PLACED APPROXIMATELY 12"-18" BELOW FINISHED GRADE AND DIRECTLY ABOVE ALL PRESSURE PIPING. TAPE, WORDING AND COLOR SHALL CONFORM TO CITY STANDARDS. 6. TRAFFIC LANE CLOSURES, MOT PLANS AND ROADWAY REPAIRS MATERIALS SHALL BE PER DIRECTION OF ROAD OWNER. CONTRACTOR TO INQUIRE WITH OWNER ABOUT REQUIREMENTS PRIOR TO BID. 7. 3M LOCATOR BALLS SHALL BE INSTALLED AT EACH FITTING IN THE PIPE LINE CHANGING DIRECTION AND AT EACH CONCRETE CONNECTION. BRICKS FOR 8. 3M LOCATORS TO BE PROVIDED BY DEVELOPER AS SPECIFIED BY O.U.A. PADS NOTE: VALVE NUT EXTENSION IS REQUIRED ON ALL VALVES WITH MORE THAN 36" OF COVER. EXTEND NUT TO WITHIN 18" OF VALVE BOX RIM. PROVIDE SOLID BRICK PAD FOR VALVE BOX TO SIT ON. QUA n#111TYPICAL VALVE SETTING ASPHALTIC CONCRETE OVERLAY AREA SEE DRAWINGS FOR LIMITS SURFACE REPLACEMENT W+4' _I 6°° _ TOP OF TRENCH WIDTii� 2" MIN. �` I W I T 2T (12" MIN.) EXISTING BASE PROPOSED BASE MAX, I PIPE ,O. , D.1 MAX. o UNDISTURBED EARTH EXISTING ASPHALT SURFACE BACKFILLED & COMPACTED TO 98% MAX. DENSITY AT +/- 2% OF OPTIMUM MOISTURE DETERMINED BY MODIFIED PROCTOR TEST AASHTO T-180/ASTM D 1557. IN 6" LOOSE THICKNESS LIFTS. NOTES: 1. BACKFILL MATERIALS SHALL CONSIST OF CLEAN EARTH FILL COMPRISED OF SAND, SAND AND CLAY, GRAVEL, CRUSHED ROCK OR OTHER MATERIALS FROM GROUPS A-1, A-2 OR A-3, AASHTO CLASSIFICATION, FREE FROM ORGANIC MATTER AND VEGETATION, DEBRIS LARGE CLODS OF EARTH OR STONES. UNSUITABLE IN -SITU MATERIALS SUCH AS MUCK, DEBRIS, LARGE ROCK AND ROOTS SHALL BE REMOVED AND DISPOSED BY THE CONTRACTOR. 2. THE PIPE SHALL BE FULLY SUPPORTED ALONG ENTIRE LENGTH. 3. THE PIPE TRENCH SHALL REMAIN DRY DURING PIPE LAYING OPERATIONS. 4. ALL TRENCH WORK SHALL CONFORM TO LATEST STANDARDS AS SET FORTH BY THE FLORIDA TRENCH SAFETY ACT AND OR OSHA. 5. FOUR INCH WIDE DETECTABLE TAPE SHALL BE PLACED APPROXIMATELY 12"-18" BELOW FINISHED GRADE AND DIRECTLY ABOVE ALL PRESSURE PIPING. TAPE, WORDING AND COLOR SHALL CONFORM TO CITY STANDARDS. 6. BACKFILL SHALL BE COMPACTED IN 6" LAYERS WITH MECHANICAL TAMPERS FOR THE FULL WIDTH OF THE TRENCH AND UP TO THE BOTTOM OF THE ROADWAY BASE. PARTICULAR ATTENTION MUST BE GIVEN TO THE ADEQUATE COMPACTION OF THE HAUNCHES OF THE PIPE. THE BACKFILL SHALL BE COMPACTED TO 98% AASHTO T-180/ASTM D 1557 TAKEN AT THE SPRING LINE, AT ONE FOOT ABOVE THE CROWN OF THE PIPE, AND EVERY FOOT VERTICALLY THEREAFTER. 7. BASE MATERIAL SHALL BE THE SAME TYPE AS THE MATERIALS REMOVED. 8. SURFACE REPLACEMENT SHALL BE F.D.O.T. MIX TO MATCH EXISTING PAVEMENT, WITH A THICKNESS EQUAL TO THE EXISTING OR 2" WHICHEVER IS GREATER. 9. PAVEMENT JOINTS SHALL BE MECHANICALLY SAWED BUTT JOINTS, HEATED, RAKED AND SPRAYED WITH A REJUVENATING AGENT. THE PATCH AREA SHALL BE A SMOOTH PLANE SUCH THAT A STRAIGHT EDGE PLACED ACROSS THE PATCH, PARALLEL TO THE TRAFFIC FLOW AND EXTENDING TO UNDISTURBED PAVEMENT SHALL SHOW NO MORE THAN 1/4" IRREGULARITY IN ANY 15 FT. SECTION. ANY IRREGULARITY SHALL BE CORRECTED IN ACCORDANCE WITH F.D.O.T. SPECIFICATIONS. 10. "COLD PATCH" SHALL BE USED FOR TEMPORARY REPAIRS ONLY, AND FOR A PERIOD NOT TO EXCEED 30 DAYS. 11. TRAFFIC LANE CLOSURES, MOT PLANS AND ROADWAY REPAIRS MATERIALS SHALL BE PER DIRECTION OF ROAD OWNER. CONTRACTOR TO INQUIRE WITH OWNER ABOUT REQUIREMENTS PRIOR TO BID. 12. 3M LOCATOR BALLS SHALL BE INSTALLED AT EACH FITTING IN THE PIPE LINE CHANGING DIRECTION AND AT EACH CONNECTION. 13. 3M LOCATORS TO BE PROVIDED BY DEVELOPER AS SPECIFIED BY O.U.A. OUA S. TRENCH REPAIR DETAILS PAVED AREAS S. NEWLINEES TYPICAL TRENCH DETAIL I 10/15 I QUA #13 R/W OR EASEMENT LINE VALVE & VALVE BOX VALVE & VALVE BOX ROAD SURFACE OR OTHER - AREA TO BE DRILLED EXIST. GRADE \, \ADAPTER\ �\ �_ 2, a_MIN. x o MIN. QUA ##12 HDPE PIPELINE HDPE PIPE INE \/AI \/r ADAPTER PERPENDICULAR CONNECTION PLAN VIEW [:ll HDPE-MJ ADAPTER 4° MA SLOPE _j ZING D.I.P. OR P.V.C. PIPELINE STRAIGHT RUN CONNECTION MJ FITTING NOTES: 1. DIRECTIONAL DRILLS SHALL BE COMPLETED USING DR11 HDPE PIPE, DIP SIZE: FOR WATER AND SANITARY FORCE MAIN IPS SIZE: FOR VACUUM SEWER. 2. ALL DIRECTIONAL DRILLS SHALL BE AT A DEPTH OF 1OX PIPE DIAMETER BELOW THE ROADWAY SURFACE OR 4' WHICHEVER IS GREATER. 3. ALL HDPE MUST BE COLOR CODED (SAFETY BLUE -WATER, SAFETY GREEN FOR SEWER AND PANTONE PURPLE FOR RECLAIMED WATER); BUTT FUSION WELDED; AND CONNECTED WITH HDPE-MJ ADAPTER. 4. 10 GUAGE SOLID COPPER LOCATING WIRES SHALL BE TAPED TO PIPE FROM VALVE TO VALVE AT A SPACING NO GREATER THAN 5 FEET AND PULLED WITH THE PIPE. SEE D17 FOR ADDITIONAL DETAILS. 5. GRAVITY SEWER BORES AS PREAPPROVED BY QUA. DIRECTIONAL DRILLING DETAIL 8 LF 12" CMP v INV. EL.= 23.40 v L X 1' x _ 25.0' Y4.uLr x 3.5' p 8LF12"CMP INV. EL.= 23.50 25.8' 4,25.91 v ° 18" c INV. ELEV. = 23.34' 2 ° 1 24. 24.00 ° 03/23 NE 5th ST and NE 3 rd AVE D ETAI L N.T.S. INEWLINEE ? 7' v y RIM EL V. = 2 .68' 18" RCP INV. ELEV. = 1 .48' 5' RCP W V. EL E V. = 1 .58' " 5' RCP E l EL = 3 .58' D D x23.6' 9 LF 12" CMP INV. EL. 23.85 �24.4' x24 3' 23. E p 9 LF 12" CMP INV. D EL.= 23.85 v +24.0' X24 2� 24.1' g ° D X 26.20 N X26.10 NE 4th ST and NE 3rd AVE DETAIL 2'-0" De.-,.-.,, y OPTION A Sidewalk ngs OPTION B ISOMETRIC VIEW 5-0" (Shown) Sidewalk Sidewalk Curb R 4'-0" Min. Ramp PLAN VIEW CR-E 15 QUA 19 S. I NEWLINES DETECTABLE WARNING AND SIDEWALK CURB 03/15 1 FDOT RAMP DETAIL N.T.S. INEWLINES 01-19-20231 REVISED PLANS PER TRC MEETING SLD PDC THIS DOCUMENT, TOGETHER WITH THE CONCEPTS AND DESIGNS PRESENTED HEREIN, AS AN INSTRUMENT OF SERVICE, IS INTENDED ONLY FOR THE SPECIFIC PURPOSE AND CLIENT FOR WHICH IT WAS PREPARED. REUSE OF AND LS52j IMPROPER RELIANCE ON THIS DOCUMENT WITHOUT WRITTEN AUTHORIZATION AND ADOPTION BY STEVEN L DOBBS, P.E., SHALL BE WITHOUT LIABILITY TO NEWLINES ENGINEERING do SURVEY AND STEVEN L. DOBBS ENGINEERING, LLC. ALL CONCRETE TO BE CLASS B' 3500 PSI (UNLESS OTHERWISE NOTED) MINOR SUBDIVISION PLAN DETAILS -3 GLENWOOD PARK LYING IN SEC 15, TOWNSHIP 37 SOUTH, RANGE 35 EAST, OKEECHOBEE CITY, FLORIDA NEWLI I�ES 101 ANn CONSHI I /SIN I b LLC cc STEVEN L. DOBBS, P.E. PROJECT NO. FL22024 DRAWN BY J M SCALE AS SHOWN DATE 2023-03-24 FLORIDA CERTIFICATE OF AUTHORIZATION NO. 00029206 DATE STEVEN L. DOBBS ENGINEERING, LLC SHEET J62 JAKES WAY OKEECHOBEE, FL 34974, PHONE (863) 824-7644 C602 OF 19 6%4' 2'x2' CONCRETE F PLUG & CLEAN -OUT INVERTED PLUG 1 WITH CON( 8"x6" P.V.C. TEE-WYE 6" P.V.C. BEND AS REQUIRED 8"x6" P.V.C. TEE-WYE TRENCH i CE OF MAIN SEWER PLAN EASEMENT, R/W OR PROPER 6" PVC EASEMENT, R/W OR PROPERTY LINELATERAL 1/4 P2'x2'x4" CONCRETE PAD TYR., 1 FOOT MICLEAN-OUT WITH INVERTEDFLUSH WITH CONCRETE 3'-0" MIN. 4.�45° BEND 6"x4" WYESLOPE 1/4 " PERTYP., 1 /8 " PER FOOT MIN. SINGLE SERVICE CONNECTION 6"" P.V.C. SERVICE LATERAL SECTION x2'x4" CONCRETE PAD 4" MIN. INDIVIDUAL HOUSE CONNECTION CLEAN -OUT WITH INVERTED PLUG FLUSH WITH CONCRETE -ALL ENDS TO BE PLUGGED & SEALED W/STD. STOPPERS OR PLUGS e "-PROPERTY LINE 6" X 6" X 4" X 4" STD. P.V.C. DOUBLE Y BRANCH 2'x2'x4" CONCRETE PAD 4" MIN. INDIVIDUAL HOUSE CONNECTION CLEAN -OUT WITH INVERTED PLUG FLUSH WITH CONCRETE EASEMENT, R/W OR PROPERTY LINE 2'2'4" CONCRETE PAD -OUT WITH ED PLUG FLUSH ONCRETE �---PLUG & SEAL CX6" X 4" X 4" STD. P.V.C. DOUBLE 'Y' BRANCH TO BE DETERMINED IN THE FIELD (60° MAX.) NDISTURBED EARTH DOUBLE SERVICE CONNECTION NOTES: 1. SERVICE LATERALS SHALL TERMINATE AT PROPERTY LINE AT A DEPTH OF 3 FEET, PLUGGED WATERTIGHT WITH CLEAN -OUT. 2. THE MINIMUM DIAMETER OF ALL SINGLE HOUSEHOLD CONNECTIONS SHALL BE 4"MINIMUM ALL OTHERS SHALL BE 6" AND ALL DOUBLE SERVICES 3. CONNECTION TO O.U.A. LATERAL SHALL BE MADE WITH A CLEAN -OUT AT PROPERTY LINE BY THE CONTRACTOR OR CUSTOMER MAKING THE CONNECTION, WITH A 2'x2'x4" CONCRETE PAD WITH A INVERTED PLUG, BOTH TO BE SET AT FINAL GRADE TYPICAL SEWER SERVICE CONNECTION MECHANICAL THRUST RESTRAINT CHART 2 MAIN RUN, in BRANCH, in TEE LARGE SIZE SMALL LARGE REDUCER PVC DIP PVC DIP 4 4 1 1 6 4 33 21 6 4 1 1 8 4 60 38 6 6 1 1 8 6 35 22 8 4 1 1 10 4 81 51 8 6 1 1 10 6 61 39 8 8 7 5 10 8 33 21 10 6 1 1 12 4 101 64 10 8 1 1 12 6 85 54 10 10 21 14 12 8 62 39 12 6 1 1 16 4 138 87 12 8 1 1 16 6 126 79 12 12 36 24 16 8 109 68 16 6 1 1 16 12 63 40 16 8 1 1 18 4 154 97 16 16 65 43 18 6 144 91 18 6 1 1 18 8 129 81 18 8 1 1 20 4 171 107 18 18 79 52 20 6 161 101 20 6 1 1 20 8 148 93 20 8 1 1 20 12 113 71 20 20 92 61 24 4 201 127 24 6 1 1 24 6 194 122 24 8 1 1 24 8 183 115 24 24 118 78 24 12 154 97 THRUST RESTRAINT CHART BASED UPON THE FOLLOWING: PVC DIP PIPE MATERIAL, AS NOTED SP SOIL TYPE (designer to confirm) 1.5 SAFETY FACTOR (minimum) 3 TRENCH TYPE (designer to confirm) 2.5 DEPTH OF BURY, ft (designer to confirm) 150 TEST PRESSURE, psi (minimum) THE MINIMUM LENGTH OF PIPE OUT OF ANY VALVE OR FITTING SHOULD BE 20 LF. FITTINGS NOT SHOWN TO BE CALCULATED UTILIZING THE CRITERIA LISTED ABOVE AND SUBMITTED IN A SHOP DRAWING VALUES SHOWN IN CHART INDICATE LENGTH (LF) OF PIPE TO BE RESTRAINED ON EITHER SIDE OF ITEM LISTED NOTE 1:ANY CONDITION OTHER THAN THOSE LISTED ABOVE (including poly -wrapped DIP) SHALL REQUIRE REVISION OF THE TABLE IN ACCORDANCE WITH EBAA IRON, INC., RESTRAINT LENGTH CALCULATOR (V. 5.4). (http://www.ebac.com/engineering.htm or http://rcp.ebaa.com) NOTE 2:THE REVISED CHARTS SHALL BE SUBMITTED TO QUA AS A SHOP DRAWING SUBMITTAL. WATER THRUST RESTRAINT 10/15 OUA 51 N.T.S. I NEWLINEE 10/15 IOUA #31 MECHANICAL THRUST RESTRAINT CHART 1 PIPE 90° BEND 45° BEND 22 1 2° BEND 11 1 4° BEND DEADEND VALVE SIZE, in PVC DIP PVC DIP PVC DIP PVC DIP PVC DIP 4 21 16 9 7 5 4 2 2 45 29 6 28 23 12 10 6 5 3 3 63 40 8 37 29 16 12 8 6 4 3 83 53 10 44 35 18 15 9 7 5 4 99 63 12 51 41 21 17 11 8 5 4 116 74 14 57 46 24 19 12 10 6 5 132 83 16 64 51 27 21 13 11 7 5 149 94 18 70 56 29 24 14 12 7 6 164 104 20 76 61 32 26 16 13 8 6 179 113 24 87 70 36 29 18 14 9 7 208 131 THRUST RESTRAINT CHART BASED UPON THE FOLLOWING: PVC DIP PIPE MATERIAL, AS NOTED SP SOIL TYPE (designer to confirm) 1.5 SAFETY FACTOR (minimum) 3 TRENCH TYPE (designer to confirm) 2.5 DEPTH OF BURY, ft (designer to confirm) 150 TEST PRESSURE, psi (minimum) THE MINIMUM LENGTH OF PIPE OUT OF ANY VALVE OR FITTING SHOULD BE 20 LF. FITTINGS NOT SHOWN TO BE CALCULATED UTILIZING THE CRITERIA LISTED ABOVE AND SUBMITTED IN A SHOP DRAWING VALUES SHOWN IN CHART INDICATE LENGTH (LF) OF PIPE TO BE RESTRAINED ON EITHER SIDE OF ITEM LISTED NOTE 1:ANY CONDITION OTHER THAN THOSE LISTED ABOVE (including poly -wrapped DIP) SHALL REQUIRE REVISION OF THE TABLE IN ACCORDANCE WITH EBAA IRON, INC., RESTRAINT LENGTH CALCULATOR (V. 5.4). (http://www.ebcia.com/engineering.htm or http://rcp.ebac.com) NOTE 2:THE REVISED CHARTS SHALL BE SUBMITTED TO QUA AS A SHOP DRAWING SUBMITTAL. WATER THRUST RESTRAINT I 1o/c5 1 QUA #WI Eon NVERTED PLUG FLUSH W/ CONCRETE RAFFIC AREAS) GRADE 2' SO 3000 P 90" ELBOW (SEWER SWEEP) TYPICAL MAIN LINE TERMINAL CLEANOUT GRADE 2' SQUARE, 4" THICK 3000 P.S.I. CONC. PAD 6" CLEANOUT ASSEMBLY W/ SCREWED CAP- INVERTED PLUG FLUSH W/ CONCRETE PAD (NON -TRAFFIC AREAS) 6" P.V.C. WYE TO STREET SERVICE TO BUILDING TYPICAL SERVICE LATERAL ONE WAY CLEANOUT NOTES 1. ONE WAY CLEANOUT (SWEEP TO STREET SERVICE). 2. CLEAN OUT SHALL BE LOCATED ON RIGHT OF WAY LINE. 3. IN TRAFFIC AREAS A METAL CLEANOUT COVER AND LID SHALL BE INSTALLED OVER PVC CLEANOUT. 4. ALL CLEAN OUT'S REQUIRE AN INSPECTION. TYPICAL CLEANOUT 10/15 I QUA #32 Ki T c I r.ir=�nii iNir=c Steet--Round Pipe-2 213" x 11 Carru ation THRUST RESTRAINT CHART BASED UPON THE FOLLOWING: PVC DIP PIPE MATERIAL, AS NOTED SP SOIL TYPE (designer to confirm) 1.5 SAFETY FACTOR (minimum) 3 TRENCH TYPE (designer to confirm) 2.5 DEPTH OF BURY, ft (designer to confirm) 150 TEST PRESSURE, psi (minimum) THE MINIMUM LENGTH OF PIPE OUT OF ANY VALVE OR FITTING SHOULD BE 20 LF. FITTINGS NOT SHOWN TO BE CALCULATED UTILIZING THE CRITERIA LISTED ABOVE AND SUBMITTED IN A SHOP DRAWING VALUES SHOWN IN CHART INDICATE LENGTH (LF) OF PIPE TO BE RESTRAINED ON EITHER SIDE OF ITEM LISTED NOTE 1:ANY CONDITION OTHER THAN THOSE LISTED ABOVE (including poly -wrapped DIP) SHALL REQUIRE REVISION OF THE TABLE IN ACCORDANCE WITH EBAA IRON, INC., RESTRAINT LENGTH CALCULATOR (V. 5.4). (http://www.ebcia.com/engineering.htm or http://rcp.ebac.com) NOTE 2:THE REVISED CHARTS SHALL BE SUBMITTED TO QUA AS A SHOP DRAWING SUBMITTAL. WATER THRUST RESTRAINT I 1o/c5 1 QUA #WI Eon NVERTED PLUG FLUSH W/ CONCRETE RAFFIC AREAS) GRADE 2' SO 3000 P 90" ELBOW (SEWER SWEEP) TYPICAL MAIN LINE TERMINAL CLEANOUT GRADE 2' SQUARE, 4" THICK 3000 P.S.I. CONC. PAD 6" CLEANOUT ASSEMBLY W/ SCREWED CAP- INVERTED PLUG FLUSH W/ CONCRETE PAD (NON -TRAFFIC AREAS) 6" P.V.C. WYE TO STREET SERVICE TO BUILDING TYPICAL SERVICE LATERAL ONE WAY CLEANOUT NOTES 1. ONE WAY CLEANOUT (SWEEP TO STREET SERVICE). 2. CLEAN OUT SHALL BE LOCATED ON RIGHT OF WAY LINE. 3. IN TRAFFIC AREAS A METAL CLEANOUT COVER AND LID SHALL BE INSTALLED OVER PVC CLEANOUT. 4. ALL CLEAN OUT'S REQUIRE AN INSPECTION. TYPICAL CLEANOUT 10/15 I QUA #32 Ki T c I r.ir=�nii iNir=c Steet--Round Pipe-2 213" x 11 Carru ation Minimum Cover in. Maximum Cover ft. Sheet thickness in Inches Ga Sheet thickness in Inches D Area 0.064 0.079 0.109 0.138 0.168 0.064 0.079 9 0.138 0.168 in. .ft. 16 14 12 10 8 16 14 10 8 12 0.79 12 12 NA NA NA 100+ 100+ NA NA 15 123 12 12 NA NA NA 100+ 100+ ;NA NA NA 18 1.77 12 12 12 NA NA 100+ 100+ + NA NA 21 2.4 12 12 12 NA NA 100+ 100+ + NA NA 24 314 12 12 12 NA NA 100+ 100+ + NA NA 30 4.91 12 12 12 NA NA 82 100+ 100+ NA NA 36 7.1 12 12 12 12 NA 68 86 100+ 100+ NA 42 9.6 12 12 12 12 NA 51 73 100+ 100+ NA 48 12.6 12 12 12 12 12 40 64 90 100+ 100+ 54 16 12 12 12 12 12 NS 57 80 100+ 100+ 60 19.6 NS NS 12 12 12 NS NS 72 93 100+ 66 23.8 NS NS 12 12 12 NS NS NS 84 100+ 72 28.3 NS NS NS 12 12 NS NS NS 77 94 78 332 NS NS NS NS 12 NS NS NS NS 87 84 1 38.5 NS NS NS NS 12 NS NS NS NS 80 Steel -Round Pipe-3" x 1" Corrugation Minimum Cover m. Maximum Cover ft. Sheet thickness in Inches Ga Sheet thickness in Inches Ga D Area 0.064 0.079 0.109 1 0.138 0.168 0.064 0.079 0.109 0.138 0.168 in. ft. 16 14 12 10 8 16 14 12 10 8 36 7A 12 12 12 NA NA 79 99 100+ NA NA 42 9.6 12 12 12 NA NA 67 84 100+ NA NA 48 12.6 12 12 12 12 NA 59 74 100+ 100+ NA 54 16 12 12 12 12 NA 1 52 65 92 100+ NA 60 19.6 12 12 12 12 NA 47 59 83 100+ NA 66 23.8 12 12 12 12 12 42 53 75 97 100 72 28.3 12 12 12 1 12 12 38 48 1 69 89 100 78 33.2 12 12 12 12 12 35 45 63 82 100 84 38.5 12 12 12 12 12 33 41 58 76 93 90 44.2 12 12 12 12 12 30 38 54 70 87 96 50.3 NS 12 12 12 12 NS 36 51 66 81 102 56.7 NS 13 13 13 13 NS 33 48 62 76 108 63.6 NS NS 14 14 14 NS NS 45 58 72 114 70.9 NS NS 15 15 15 NS NS 42 55 68 120 78.5 NS NS 15 15 15 NS NS 40 52 64 132 95 NS NS NS 17 17 NS NS NS 47 58 PIPE COVERAGE FOR PROPOSED CMP CULVERT SAFETY RED COLOR c W A 1'-6" SDWK. V-6" H=CURB HEIGHT WIDTH H INCHES W FEET 3 3 4 4 5 5 6 6 7 7 8 8 9 9 SECTION A -A VARIABLE SDWK. 1'-6" H=CURB HEIGHT rOM: 1V MAk WIDTH If CURB RAMP OPENING TO BE FLUSH WITH ROADWAY HOT POURED RUBBER ASPHALT JOINT SEALER PROPOSED CURB 1/2" PREFORMED EXPANSION JOINT FILLER ROADWAY CONCRETE CURB RAMP, 4" THICK o CONCRETE CRADLE 4" WIDE (MONOLITHIC WITH CURB) (PAID FOR IN COST OF CURB) 4» WIDTH THE SAME AS APPROACH CURB CURB TO BE FLUSH WITH ROADWAY PAVEMENT 4" MIN. SIDEWALK LANDING AREA WIDTH VARIABLE CURB RAMP 2% MAX. 12H:1V MAX. f- r SECTION THROUGH CURB RAMP HANDICAP CURB RAMP TYPE 5 01/22 GN 72 03/23 FL - F_6" MIN., 8" MAX. COATING V WIDTH IVIr CURB 0 0 0 0 0 z zo a- O O O O O DIRECTION OF TRAVEL QD� 0 0 0 0 0 Z m 0.65" MIN. BASE w O O O O O TO BASE T.D. C) U 0 0 0 0 0 1 SPACING 1.6" MIN. TO 2.4" MAX. CENTER TO CENTER T.D. SIDEWALK SPACING PLAN VIEW 0.45" MIN. TO 0.90" MAX. TOP TRUNCATED DIAMETER DOME (T.D.) SIDEWALK - L 0.20" 0.90" MIN. TO 1.4" MAX. BASE DIAMETER NOTES: ELEVATION 1. LANDING AREA, APPROACH SIDEWALK TRANSITIONS, AND CURB RAMP SHALL BE KEPT CLEAR OF OBSTRUCTIONS. 2. DIMENSIONS SHOWN IN TABLES ARE FOR RELATIVELY FLAT SIDEWALK AREA. CARE SHOULD BE TAKEN WHEN DETERMINING CURB RAMP SIZE BASED ON CURB HEIGHT (I) WHERE ELEVATION OF CURB AND SIDEWALK VARY DRASTICALLY IN AREA OF PROPOSED CURB RAMP. 3. CURB (DROPPED CURB) GUTTER LINE TO BE FLUSH WITH ROADWAY PAVEMENT A MINIMUM OF 4 FEET FOR ALL CURB RAMPS. 4. FOR CURB RAMP TYPES 5 AND 6, IF A GRASS BUFFER DOES NOT EXIST, SLOPE CURB TO EQUAL SLOPE OF ADJACENT CURB RAMP. 5. SIDEWALK AND CURB RAMP WITHIN AREA ENCLOSED BY HEAVY LINES TO BE PAID FOR AS CONCRETE SIDEWALK OF THE APPROPRIATE OF ADJACENT THICKNESS. 6. CURB AND HEADER WINING AREA ENCLOSED BY HEAVY LINES TO BE PAID FOR A AS VERTICAL CURB OR SLOPING CURB OF THE APPROPRIATE ADJACENT SIZE AND KIND. 7. WHERE THE DISTANCE FROM THE GUTTER LINE TO THE OUTSIDE EDGE OF SIDEWALK IS 6 FEET OR LESS, CURB RAMP TYPE 7 SHOULD BE USED INSTEAD OF CURB RAMP TYPE 1 THROUGH 4. 8. THE PUBLIC SIDEWALK CURB RAMP, DETECTABLE WARNING SURFACE (SHADED AREA) SHALL BE SAFETY RED COLOR ON CONCRETE OR 70% COLOR CONTRACT FROM OTHER SURFACE SUCH AS BRICK. 9. CROSSWALKS AND STOP LINES MAY BE MARKED OR UNMARKED, SEE PLANS. 10. PREFERRED AND ALTERNATE TREATMENTS SHOULD NOT BE INTERMIXED WITHIN THE SAME INTERSECTION. 11. DIMENSIONS SHOWN IN TABLE ARE FOR 3 INCH TO 9 INCH CURB HEIGHTS WHERE THE CURB HEIGHTS ARE OTHER THAN WHAT IS PROVIDED IN THE TABLES, THE DIMENSIONS OF THE RAMPS WILL HAVE CALCULATED BASED ON CROSS SLOPES SHOWN. 01/22 CN 17 N.T.S. INEWLINE DETECTABLE WARNING SURFACE 2 CD T) rn = w 00 � w � oW PLAN o O O N :�i C) z z W 4,-4„ Lu W W och 3-0 z o W w W Ln Cf) X GRATE -A w `, 2" CL. �I{�> J N 18„ 00 52F BOLTS EYE INDEX SEE 201 #4 BARS @ 12"0 WEEPHOLE 12" CTRS. W/ROCK/FILTER SECTION FABRIC RECOMMENDED MAXIMUM PIPE SIZE: 3'-0" WALL-24" PIPE PIPE I 3'-4" 2 1 „ 2 1 5 1 5" C� 2„ ? 2„ O O O O O O O O O �O O O O O I O O � O O O O O O O O O O 3'- 4 APPROX. WEIGHT 465 LBS. 3'-4" Lnp PIPE N _ rnl0 `�_ co @ w 0 Cn a Ir w m m N � N N STRAIGHT BARS 2"X 4" RETICULINE BARS 1 4"X6" BANDS 1 2"X4" APPROX. WEIGHT 215 LBS. NOTES: 1) STEEL GRATES ARE REQUIRED ON INLETS 2) ALL INLETS WILL BE CAST TO PROVIDE A 18" WITH TRAVERSABLE SLOTS AND ON INLETS SUMP BELOW LOWEST CULVERT INVERT WHERE BICYCLE TRAFFIC IS ANTICIPATED. PRE -CAST TYPE ' E' CATCH BASIN oNI T Q FL DR 6 T c niF7\nn in�c 01-19-20231 REVISED PLANS PER TRC MEETING SLD PDC THIS DOCUMENT, TOGETHER WITH THE CONCEPTS AND DESIGNS PRESENTED HEREIN, AS AN INSTRUMENT OF SERVICE, IS INTENDED ONLY FOR THE SPECIFIC PURPOSE AND CLIENT FOR WHICH IT WAS PREPARED. REUSE OF AND IMPROPER RELIANCE ON THIS DOCUMENT WITHOUT WRITTEN AUTHORIZATION AND ADOPTION BY STEVEN L. DOBBS, P.E., SHALL BE WITHOUT LIABILITY TO NEWLINES ENGINEERING do SURVEY AND STEVEN L. DOBBS ENGINEERING, LLC. ALL CONCRETE TO BE CLASS 'B' 3500 PSI (UNLESS OTHERWISE NOTED) MINOR SUBDIVISION PLAN DETAI LS - 4 GLENWOOD PARK LYING IN SEC 15, TOWNSHIP 37 SOUTH, RANGE 35 EAST, OKEECHOBEE CITY, FLORIDA NEWLII�ES ID ANn CONSHI I AIN I b LLC cc STEVEN L. DOBBS, P.E. PROJECT NO. FL22024 DRAWN BY J M SCALE AS SHOWN DATE 2023-03-24 FLORIDA CERTIFICATE OF AUTHORIZATION NO. 00029206 DATE STEVEN L. DOBBS ENGINEERING, LLC SHEET 1062 JAKES WAY OKEECHOBEE, FL 34974, PHONE (863) 824-7644 C603 OF 19 1.6" MIN. TO 2.4" MAX. CENTER TO CENTER T.D. SIDEWALK SPACING PLAN VIEW 0.45" MIN. TO 0.90" MAX. TOP TRUNCATED DIAMETER DOME (T.D.) SIDEWALK - L 0.20" 0.90" MIN. TO 1.4" MAX. BASE DIAMETER NOTES: ELEVATION 1. LANDING AREA, APPROACH SIDEWALK TRANSITIONS, AND CURB RAMP SHALL BE KEPT CLEAR OF OBSTRUCTIONS. 2. DIMENSIONS SHOWN IN TABLES ARE FOR RELATIVELY FLAT SIDEWALK AREA. CARE SHOULD BE TAKEN WHEN DETERMINING CURB RAMP SIZE BASED ON CURB HEIGHT (I) WHERE ELEVATION OF CURB AND SIDEWALK VARY DRASTICALLY IN AREA OF PROPOSED CURB RAMP. 3. CURB (DROPPED CURB) GUTTER LINE TO BE FLUSH WITH ROADWAY PAVEMENT A MINIMUM OF 4 FEET FOR ALL CURB RAMPS. 4. FOR CURB RAMP TYPES 5 AND 6, IF A GRASS BUFFER DOES NOT EXIST, SLOPE CURB TO EQUAL SLOPE OF ADJACENT CURB RAMP. 5. SIDEWALK AND CURB RAMP WITHIN AREA ENCLOSED BY HEAVY LINES TO BE PAID FOR AS CONCRETE SIDEWALK OF THE APPROPRIATE OF ADJACENT THICKNESS. 6. CURB AND HEADER WINING AREA ENCLOSED BY HEAVY LINES TO BE PAID FOR A AS VERTICAL CURB OR SLOPING CURB OF THE APPROPRIATE ADJACENT SIZE AND KIND. 7. WHERE THE DISTANCE FROM THE GUTTER LINE TO THE OUTSIDE EDGE OF SIDEWALK IS 6 FEET OR LESS, CURB RAMP TYPE 7 SHOULD BE USED INSTEAD OF CURB RAMP TYPE 1 THROUGH 4. 8. THE PUBLIC SIDEWALK CURB RAMP, DETECTABLE WARNING SURFACE (SHADED AREA) SHALL BE SAFETY RED COLOR ON CONCRETE OR 70% COLOR CONTRACT FROM OTHER SURFACE SUCH AS BRICK. 9. CROSSWALKS AND STOP LINES MAY BE MARKED OR UNMARKED, SEE PLANS. 10. PREFERRED AND ALTERNATE TREATMENTS SHOULD NOT BE INTERMIXED WITHIN THE SAME INTERSECTION. 11. DIMENSIONS SHOWN IN TABLE ARE FOR 3 INCH TO 9 INCH CURB HEIGHTS WHERE THE CURB HEIGHTS ARE OTHER THAN WHAT IS PROVIDED IN THE TABLES, THE DIMENSIONS OF THE RAMPS WILL HAVE CALCULATED BASED ON CROSS SLOPES SHOWN. 01/22 CN 17 N.T.S. INEWLINE DETECTABLE WARNING SURFACE 2 CD T) rn = w 00 � w � oW PLAN o O O N :�i C) z z W 4,-4„ Lu W W och 3-0 z o W w W Ln Cf) X GRATE -A w `, 2" CL. �I{�> J N 18„ 00 52F BOLTS EYE INDEX SEE 201 #4 BARS @ 12"0 WEEPHOLE 12" CTRS. W/ROCK/FILTER SECTION FABRIC RECOMMENDED MAXIMUM PIPE SIZE: 3'-0" WALL-24" PIPE PIPE I 3'-4" 2 1 „ 2 1 5 1 5" C� 2„ ? 2„ O O O O O O O O O �O O O O O I O O � O O O O O O O O O O 3'- 4 APPROX. WEIGHT 465 LBS. 3'-4" Lnp PIPE N _ rnl0 `�_ co @ w 0 Cn a Ir w m m N � N N STRAIGHT BARS 2"X 4" RETICULINE BARS 1 4"X6" BANDS 1 2"X4" APPROX. WEIGHT 215 LBS. NOTES: 1) STEEL GRATES ARE REQUIRED ON INLETS 2) ALL INLETS WILL BE CAST TO PROVIDE A 18" WITH TRAVERSABLE SLOTS AND ON INLETS SUMP BELOW LOWEST CULVERT INVERT WHERE BICYCLE TRAFFIC IS ANTICIPATED. PRE -CAST TYPE ' E' CATCH BASIN oNI T Q FL DR 6 T c niF7\nn in�c 01-19-20231 REVISED PLANS PER TRC MEETING SLD PDC THIS DOCUMENT, TOGETHER WITH THE CONCEPTS AND DESIGNS PRESENTED HEREIN, AS AN INSTRUMENT OF SERVICE, IS INTENDED ONLY FOR THE SPECIFIC PURPOSE AND CLIENT FOR WHICH IT WAS PREPARED. REUSE OF AND IMPROPER RELIANCE ON THIS DOCUMENT WITHOUT WRITTEN AUTHORIZATION AND ADOPTION BY STEVEN L. DOBBS, P.E., SHALL BE WITHOUT LIABILITY TO NEWLINES ENGINEERING do SURVEY AND STEVEN L. DOBBS ENGINEERING, LLC. ALL CONCRETE TO BE CLASS 'B' 3500 PSI (UNLESS OTHERWISE NOTED) MINOR SUBDIVISION PLAN DETAI LS - 4 GLENWOOD PARK LYING IN SEC 15, TOWNSHIP 37 SOUTH, RANGE 35 EAST, OKEECHOBEE CITY, FLORIDA NEWLII�ES ID ANn CONSHI I AIN I b LLC cc STEVEN L. DOBBS, P.E. PROJECT NO. FL22024 DRAWN BY J M SCALE AS SHOWN DATE 2023-03-24 FLORIDA CERTIFICATE OF AUTHORIZATION NO. 00029206 DATE STEVEN L. DOBBS ENGINEERING, LLC SHEET 1062 JAKES WAY OKEECHOBEE, FL 34974, PHONE (863) 824-7644 C603 OF 19 C) z z W 4,-4„ Lu W W och 3-0 z o W w W Ln Cf) X GRATE -A w `, 2" CL. �I{�> J N 18„ 00 52F BOLTS EYE INDEX SEE 201 #4 BARS @ 12"0 WEEPHOLE 12" CTRS. W/ROCK/FILTER SECTION FABRIC RECOMMENDED MAXIMUM PIPE SIZE: 3'-0" WALL-24" PIPE PIPE I 3'-4" 2 1 „ 2 1 5 1 5" C� 2„ ? 2„ O O O O O O O O O �O O O O O I O O � O O O O O O O O O O 3'- 4 APPROX. WEIGHT 465 LBS. 3'-4" Lnp PIPE N _ rnl0 `�_ co @ w 0 Cn a Ir w m m N � N N STRAIGHT BARS 2"X 4" RETICULINE BARS 1 4"X6" BANDS 1 2"X4" APPROX. WEIGHT 215 LBS. NOTES: 1) STEEL GRATES ARE REQUIRED ON INLETS 2) ALL INLETS WILL BE CAST TO PROVIDE A 18" WITH TRAVERSABLE SLOTS AND ON INLETS SUMP BELOW LOWEST CULVERT INVERT WHERE BICYCLE TRAFFIC IS ANTICIPATED. PRE -CAST TYPE ' E' CATCH BASIN oNI T Q FL DR 6 T c niF7\nn in�c 01-19-20231 REVISED PLANS PER TRC MEETING SLD PDC THIS DOCUMENT, TOGETHER WITH THE CONCEPTS AND DESIGNS PRESENTED HEREIN, AS AN INSTRUMENT OF SERVICE, IS INTENDED ONLY FOR THE SPECIFIC PURPOSE AND CLIENT FOR WHICH IT WAS PREPARED. REUSE OF AND IMPROPER RELIANCE ON THIS DOCUMENT WITHOUT WRITTEN AUTHORIZATION AND ADOPTION BY STEVEN L. DOBBS, P.E., SHALL BE WITHOUT LIABILITY TO NEWLINES ENGINEERING do SURVEY AND STEVEN L. DOBBS ENGINEERING, LLC. ALL CONCRETE TO BE CLASS 'B' 3500 PSI (UNLESS OTHERWISE NOTED) MINOR SUBDIVISION PLAN DETAI LS - 4 GLENWOOD PARK LYING IN SEC 15, TOWNSHIP 37 SOUTH, RANGE 35 EAST, OKEECHOBEE CITY, FLORIDA NEWLII�ES ID ANn CONSHI I AIN I b LLC cc STEVEN L. DOBBS, P.E. PROJECT NO. FL22024 DRAWN BY J M SCALE AS SHOWN DATE 2023-03-24 FLORIDA CERTIFICATE OF AUTHORIZATION NO. 00029206 DATE STEVEN L. DOBBS ENGINEERING, LLC SHEET 1062 JAKES WAY OKEECHOBEE, FL 34974, PHONE (863) 824-7644 C603 OF 19 STRAIGHT BARS 2"X 4" RETICULINE BARS 1 4"X6" BANDS 1 2"X4" APPROX. WEIGHT 215 LBS. NOTES: 1) STEEL GRATES ARE REQUIRED ON INLETS 2) ALL INLETS WILL BE CAST TO PROVIDE A 18" WITH TRAVERSABLE SLOTS AND ON INLETS SUMP BELOW LOWEST CULVERT INVERT WHERE BICYCLE TRAFFIC IS ANTICIPATED. PRE -CAST TYPE ' E' CATCH BASIN oNI T Q FL DR 6 T c niF7\nn in�c 01-19-20231 REVISED PLANS PER TRC MEETING SLD PDC THIS DOCUMENT, TOGETHER WITH THE CONCEPTS AND DESIGNS PRESENTED HEREIN, AS AN INSTRUMENT OF SERVICE, IS INTENDED ONLY FOR THE SPECIFIC PURPOSE AND CLIENT FOR WHICH IT WAS PREPARED. REUSE OF AND IMPROPER RELIANCE ON THIS DOCUMENT WITHOUT WRITTEN AUTHORIZATION AND ADOPTION BY STEVEN L. DOBBS, P.E., SHALL BE WITHOUT LIABILITY TO NEWLINES ENGINEERING do SURVEY AND STEVEN L. DOBBS ENGINEERING, LLC. ALL CONCRETE TO BE CLASS 'B' 3500 PSI (UNLESS OTHERWISE NOTED) MINOR SUBDIVISION PLAN DETAI LS - 4 GLENWOOD PARK LYING IN SEC 15, TOWNSHIP 37 SOUTH, RANGE 35 EAST, OKEECHOBEE CITY, FLORIDA NEWLII�ES ID ANn CONSHI I AIN I b LLC cc STEVEN L. DOBBS, P.E. PROJECT NO. FL22024 DRAWN BY J M SCALE AS SHOWN DATE 2023-03-24 FLORIDA CERTIFICATE OF AUTHORIZATION NO. 00029206 DATE STEVEN L. DOBBS ENGINEERING, LLC SHEET 1062 JAKES WAY OKEECHOBEE, FL 34974, PHONE (863) 824-7644 C603 OF 19 PAVEMENT - (FOR PAVED AREA) N CAST IRON, ROADWAY TYPE, EXTENSION VALVE BOX (INSIDE SCREW) C.I. COVER CONCRETE VALVE PAD FINISHED GRADE (FOR \�\ NON —PAVED AREA) COMPACTED EARTH 3" PVC W/THREADED PVC INVERTED KEY PLUG (FLUSH) --TWO (2) PAIRS OF INSULATED METALLIC 10 GAUGE SOLID COPPER WIRE (TYP.) EACH PAIR HEADING ON OPPOSITE DIRECTIONS PRESSURE MAIN DUCT TAPE (5 PER PIPE LENGTH) 1. ALL PVC PIPE SHALL REQUIRE TWO PAIRS OF INSULATED METALLIC LOCATING WIRES (10 GAUGE SOLID COPPER) TAPED WITH 2" WIDE DUCT TAPE TO TOP CENTERLINE OF THE PIPE AT EVERY JOINT AND AT 4 ADDITIONAL EQUALLY SPACED POINTS PER LENGTH OF PIPE. 2. LOCATING WIRES TO TERMINATE ON EACH END AT A VALVE BOX, 4" ABOVE GROUND AND FOLDED BACK INSIDE VALVE BOX. 3. LOCATING WIRES SHALL BE CAPABLE OF DETECTION BY A CABLE LOCATOR AND PASS A FIELD CONDUCTIVITY TEST, OBSERVED BY THE O.U.A., FROM END TO END OF WIRES. 4. SPLICES SHALL BE CAPABLE OF COMPLETE SUBMERSION, SUCH AS BUTT SPLICE WITH RAYCHEM HEAT SHRINK TUBING. 5. NO MORE THAN ONE SPLICE IN LOCATING WIRES BETWEEN VALVES IS ALLOWED. 6. PROVIDE POTTING COMPOUND AT TRACER WIRE JUNCTIONS AND SPLICES. 7. THE ENDS OF ALL LOCATING WIRES, WHETHER THEY ARE SPLICED, CONNECTED, OR TERMINATED, SHALL HAVE THE LAST THREE INCHES PIG TAILED AS DETAILED HEREON. 4" WARNING TAPE METALLIC LOCATING WIRE FINISHED GRADE 18" Z IMUM) 1" MAX PVC PRESSURE MAIN PVC PIPE LOCATING WIRE PIG TAIL WIRE AFTER PASSING THROUGH #10 THW LOCATING SPLIT BOLT WIRE (SOLID COPPER 4" MIN. WIRE WITH BLUE COATING) j— — �`2') y 4" MIN. 1 /4" X 3/4" SPLIT BOLT LOCATING WIRE DETAIL LOCATION WIRE DETAILS FOR ALL ROAD CROSSINGS AND BORES * CONTRACTOR TO FIELD VERIFY VALVE VAULT COVER CENTERED OVER VALVE/FITTINGS 3 #4 AT 4" O.C. EACH SIDE OF OPENING # 4 AT 8" O.C. E.W. (MIN.) * FINISH GRADE EL. ° X Qz � �7i -- 8" TYP. �� (MIN.) ° LIQUID LEVEL CONTROL CABLES TO BE IN ONE CONDUIT, PUMP POWER CABLES TO BE IN NON —SHRINK GROUT (TYP.) SEPARATE CONDUITS SEALED IN # 5 AT 8" O.C. E.W. WETWELL T.& B.(MIN.) 2 #5 AT 4" O.C. EACH SIDE OF OPENING 2 #4 AT 4" O.C. EACH 3 #5 AT 4" O.C. SIDE OF OPENING EACH SIDE OF 6' CHAIN LINK FENCE (10 GAUGE CHAIN LINK) w/ 3 STRANDS OF BARBED WIRE REQ'D AT TOP OF FENCE 40' MIN. LIGHT POLE W/ AREA LIGHT X X X X DISCONNECT SWITCH & METER CONTROL PANEL WATER SERVICE ANTENNA & RTU PANEL 5'_0" x MIN. x o TYP. PLUG W/2" z v VENT w/ FIBERGLASS HOLE AND z o INSECT SCREEN o S PLUG _j Y 10' WIDE COMPACTED 60 0 w SHELLROCK ACCESS ROAD 0- x z �z x z z wow w / LL 0~ z 2" PVC � 1 1 N J � FORCE MAIN 1 1 /2 BACKFLOW PREVENTER z 3" O.D. G.S.P. (CORNER POST)J� R/W LINE WATER METER PLAN NOTES: 1. TERMINAL END SHALL BE MECHANICALLY RESTRAINED IN ACCORDANCE WITH QUA STANDARD DETAILS. THE NUMBER OF PIPE LENGTHS TO BE RESTRAINED SHALL BE IN ACCORDANCE WITH THE RESTRAINED JOINT TABLES. 2. SEE D9 FOR BLOW —OFF DETAILS. QUA 417 4" HDPE or PVC VENT w/STANILESS STEEL INSECT SCREEN FLANGED RETURN ELL OPENING Q0 8" (MIN.) WETWELL COVER ELEV. 26.0' ARV TO BE INSTALLED OUTSIDE VALVE VAULT GAGE TOJ B. 316 °S.S. DRESSER COCK COUPLING OR W/ CHECK CABLE )�0018PIECK VALVE 2'-0" Q HOLDERS _ (2 REQ'D.) 8" (MIN.) Lr BOTTOM SECTION AND "/-.M BASE SLAB TO BE MONOLITHICALLY POURED & SLOPE TO DRAIN Std. A.C.I. 90° HOOK---Z__l 4"x4" CONCRETE SUPPORT AT ALL GATE VALVES (MIN.) A.C.I. 90` HOOK (TYP.) # 4 AT 6" O.C. E.W. 1 —#4 BAR w/ Std. NOTES: 1. THE INTERIOR OF THE WET WELL, INCLUDING THE UNDERSIDE OF THE TOP SLAB, SHALL BE COATED WITH SEWPERCOAT OR REZCLAD AS PER MANUFACTURES RECOMMENDATIONS. THE EXTERIOR OF THE WET WELL INCLUDING THE OUTSIDE BOTTOM FOR PRE —CAST WET WELL AND THE INTERIOR AND EXTERIOR OF THE VALVE VAULT SHALL BE COATED AS REQUIRED FOR MANHOLES WITH COAL TAR EPDXY, EXCLUDING THE ABOVE GROUND EXTERIOR PORTION OF EITHER THE WET WELL AND VALVE VAULT. EACH COAT OF THE COAL TAR EPDXY OR APPROVED EQUAL SHALL BE A DIFFERENT COLOR WITH THE FINAL COAT BLACK WITH MINIMUM DRY FILM THICKNESS OF 8 MILS PER COAT 2. ALL DIP, FITTINGS, NUTS & BOLTS TO BE WIRE BRUSHED & FREE OF DEBRIS BEFORE INSTALLATION. AFTER INSTALLATION THEY SHALL BE COATED AS PER NOTE 1 ABOVE. 3. TYPE II CEMENT WITH A MIN. COMPRESSIVE STRENGTH OF 4,000 PSI AT 28 DAYS SHALL BE USED FOR WETWELL CONSTRUCTION. 4. ALL BRACKETS, HOLDERS AND RAILS TO BE STAINLESS STEEL (TYPE 316) 5. VALVE VAULT & WETWELL SHALL HAVE ALUMINUM HEAVY DUTY FRAME & COVER WITH SLAM LOCKS EACH LID. INCLUDE HASP AND STAPLE FOR PADLOCK. G.V. GROUT 12" (MIN.) 2" PVC DRAIN w/ TRAP 316 S.S. SUPPORT ELEV. 18.7' LAG PUMP ON -LEV. 18.2' LEAD PUMP ON ELEV. 17.2' BOTH PUMPS OF ALSO ALTERNATE LEAD/ LAG SEQUENCE 0 POWER JSABLE 8" MIN.- 316 S S. GUIDE RAILS INV. EL. 19.70 C-0"II MIN. °II 1 o O 18' 12" (MIN.) PRECAST WET WELL SECTION A.S.T.M. C-478 LATEST REVISION 2-8' WIDE GATES (CENTERED ON WETWELL) NOTES d_7_—TO MAIN 4" O.D. G.S.P. GATE POST 1. FENCED AREA SHALL BE LAID WITH A MINIMUM OF 6" OF 3/4 " WASHED ROCK. 2. INFLUENT MAIN SHALL BE CLEAR OF PANEL AND VAULT. 3. PLAN MAY VARY BASED UPON SPECIFIC SITE REQUIREMENTS UPON APPROVAL FROM QUA 4. EMERGENCY PUMP OUT TO BE OUTSIDE VALVE PIT STUBBED UP 3' ABOVE GROUND (SEE DETAIL D-46) TERMINAL END DETAIL I o/c5 QUA #7c� TYPICAL LIFT STATION LAYOUT (WITHIN EASEMENT) 110/c5 I QUA #All c5I LINFLUENT (18 L.F. OF D.I.P. OR PVC MIN. ° RAMNEK JOINTS (TYPICAL) LIQUID LEVEL SENSORS AS REQ'D. #5 AT 6" O.C. (MIN.) #5 AT 9" O.C. (MIN.) w/ 12", Std. A.C.I. 90° HOOK ELEV. 14.7" ° L_ 4" CLEAR * ooda� 4" CLJA:/ GRAVEL odor po o'o0 0 ° o0 0 oo°� o°� e e o000 0 0080 oa ao Ooo o e o$°o oo 000000000 o=p8=o oo0000 316 S.S. ANCHOR AS REQUIRED # 5 AT 6" O.C.E.W. (MIN.) BY PUMP MANUFACTURER BOTTOM RISER SECTION AND BASE SLAB TO BE MONOLITHICALLY POURED 6. PUMPS SHALL BE FLYGT, EMU OR ABS & OPERATE PER THE QUA REQUIREMENTS AND SHALL BE SELECTED SO THE MOTORS SHALL NOT BE OVERLOADED ALONG THE ENTIRE EXTENT OF THE PUMP CURVE. 7. SAFETY GRATE HATCH SHALL BE PROVIDED FOR ALL WETWELL COVERS. TYPICAL LIFT STATION (SECTION) # 5 AT 12" 0.C.E.W. *8. ENGINEER SHALL CARRY OUT BUOYANCY CALCULATIONS TO DETERMINE REQUIRED BASE THICKNESS. CALCULATIONS SHALL BE PROVIDED TO O.U.A. WITH SHOP DRAWINGS SUBMITTAL. 01/23 1 QUA #37 SPOOL PIECE W/ DRESSER COUPLING BETWEEN OS & Y VALVE AND CHECK VALVE 12"-18" GATE VALVE w/ HANDWHEEL (TYP.) ALUMINUM DOUBLE DOOR ACCESS FRAME & COVER TO BE CENTERED OVER CHECK VALVE AND GATE VALVE 8" TYP. I CONCRETE VALVE VAULT ARV VENT EMERGENCY PUMP CONNECTION (SEE DETAIL) CAMLOCK FITTING CHECK VALVE w/ OUTSIDE WEIGHT & LEVER (TYPICAL) HDPE UP TO UNIFLANGE (TYP.) 12" MIN. ALUMINUM DOOR ACCESS FRAME & COVER CABLE HOLDER ,<_,--ADD SAFETY GRATE HATCH CONCRETE WETWELL WO HDPE or PVC 7(D VENT w/ STAINLESS FLOOR DRAIN * STEEL INSECT SCREEN 12"-18TO WELL * SPOOL PIECE GAUGE COCKS * w (TYP. OF 2)* J v o I I 1' MIN. gCHECK VALVE w/ OUTSIDE, 2 #4 BARS 3'-0" TOP & BOTTOM (TYPICAL, WETWELL & VALVE VAULT) WEIGHT & LEVER (TYPICAL) NON —SHRINK GROUT (TYPICAL) GATE VALVE FORCE MAIN w/ HANDWHEEL (TYP.) INFLUENT NOTE: ALL PIPING & FITTINGS IN WETWELL & VALVE VAULT SHALL BE HDPE. * PER PUMP MANUFACTURER RECOMMENDATIONS TO SUIT PIPE AND VALVE SIZES AS APPROVED BY THE OUA.—MIN 9'x9' MINIMUM 12" CLEARANCE BETWEEN GAUGE COCKS/ ARV AND SIDEWALLS 1^0/ 15 QUA # c6 TYPICAL LIFT STATION (PLAN) DETAILS INCLUDED IN THIS MINIMUM STANDARDS BOOK ARE FOR DUPLEX LIFT STATIONS. TRIPLEX LIFT STATIONS AND LARGER DESIGNS WILL REQUIRE PRIOR APPROVAL BY O.U.A. LIFT STATIONS DESIGNED FOR A MOBILE GENERATOR SET—UP WILL INCLUDE EMERGENCY CONTROL BREAKER, GENERATOR RECEPTACLE LIFT STATIONS DESIGNED FOR A STATIONARY GENERATOR WILL NOT HAVE AN EMERGENCY CONTROL BREAKER, GENERATOR RECEPTACLE AND WILL ALSO INCLUDE A AUTOMATIC TRANSFER SWITCH ENGINEER/CONTRACTOR TO CONFIRM PUMP CABLE SIZE, CONDUIT SIZE AND NUMBER OF CONDUITS TO ACCOMMODATE ALL WIRING FOR PUMPS, PANEL, JUNCTION BOX, AND TO INCLUDE A SPARE 01-19-20231 REVISED PLANS PER TRC MEETING I SLD PDC THIS DOCUMENT, TOGETHER WITH THE CONCEPTS AND DESIGNS PRESENTED HEREIN, AS AN INSTRUMENT OF SERVICE, IS INTENDED ONLY FOR THE SPECIFIC PURPOSE AND CLIENT FOR WHICH IT WAS PREPARED. REUSE OF AND IMPROPER RELIANCE ON THIS DOCUMENT WITHOUT WRITTEN AUTHORIZATION AND ADOPTION BY STEVEN L. DOBBS, P.E., SHALL BE WITHOUT LIABILITY TO NEWLINES ENGINEERING do SURVEY AND STEVEN L. DOBBS ENGINEERING, LLC. GENERAL NOTES FOR DUPLEX/TRIPLEX LIFT STAT I 0 N S I 10/15 I QUA #341 ALL CONCRETE TO BE CLASS B' 3500 PSI (UNLESS OTHERWISE NOTED) MINOR SUBDIVISION PLAN DETAILS — 5 GLENWOOD PARK LYING IN SEC 15, TOWNSHIP 37 SOUTH, RANGE 35 EAST, OKEECHOBEE CITY, FLORIDA JDNEWLII�ES ANn CONSHI I AIN I b LLC cc STEVEN L. DOBBS, P.E. PROJECT NO. FL22024 DRAWN BY J M SCALE AS SHOWN DATE 2023-03-24 FLORIDA CERTIFICATE OF AUTHORIZATION NO. 00029206 DATE STEVEN L. DOBBS ENGINEERING, LLC SHEET 1062 JAKES WAY OKEECHOBEE, FL 34974, PHONE (863) 824-7644 C604 OF 19 MATCHLINE SHEET C301 MATCHLINE SEE SHEET C302 NE 5TH STREET NE 4TH STREET GRAPHIC SCALE 20 0 10 20 40 80 x LEGEND PROPOSED PALM TREE (13 PROVIDED) PROPOSED TREE (10 PROVIDED) PROPOSED SHRUB (174 PROVIDED) EXISTING PALM TREE TO REMAIN (3 TOTAL) - EXISTING TREE TO REMAIN (52 TOTAL) EXISTING PINE TREE TO REMAIN (5 TOTAL) NOTE 1. THERE ARE EXISTING TREES ONSITE THAT WILL MEET SOME OF THE LANDSCAPING REQUIREMENT. SINCE THERE IS NOT A TREE SURVEY, THIS WILL BE FIELD ADJUSTED. 2. THIS PLAN FOR SITE APPROVAL AND ONLY INDICATES THE LOCATION AND TYPE OF PROPOSED LANDSCAPING. THE SELECTED PLANT TO BE INSTALLED WILL HAVE TO MEET THE CITY OF OKEECHOBEE'S DIVISION 4 LANDSCAPE CODE FOR TYPE AND SIZE OF PLANTS INSTALLED. 3. THE NORTH PARCEL HAS ALREADY BEEN THROUGH SITE PLAN AND WAS PREVIOUSLY APPROVED AND CERTIFIED PRIOR TO CERTIFICATE OF OCCUPANCY FOR THE LATEST CITY OF OKEECHOBEE TRC APPROVAL. 4. CONSIDERATION WILL BE MADE TO PROTECT THE OVERHEAD UTILITY LINES FROM MATURE TREE GROWTH. 5. PLANTINGS WILL BE ELECTED FROM SOUTH FLORIDA WATER MANAGEMENT DISTRICT'S XERISCAPE PLAN GUIDE, WITH AT LEAST 75% OF THE TOTAL REQUIRED PLANS BEING NATIVE VERY DROUGHT TOLERANT SPECIES AS LISTED IN THAT PLANT GUIDE. 6. TREES SHALL BE AT LEAST 10' HIGH AND 2" DIAMETER MEASURED 4' ABOVE GROUND LEVEL AT THE TIME OF PLANTING. 7.LANDSCAPE AREAS WILL BE MULCH AROUND TREES AND SHRUBS. 8. FOR A DIVERSITY OF PLANTINGS, CABBAGE PALM (CAULIS PALMA) AND PINDO PALM (PINDO PALMA) WILL BE USE IN PLACES OTHER THAN DESCRIBE BELOW: a. FOR TREES UNDER POWER LINES, SILVER BUTTONWOOD (ARGENTUM BUTTONWOOD), AND CRAPE MYRTLE (CRAPE MYTUS) WILL BE USED. b. FOR SHADE IN THE PARKING AREAS, LIVE OAK (VIVAMUS QUERCUS), BLACK OLIVE (OLIVAE NIGRAE) OR GREEN BUTTONWOOD (GREEN BUTTONWOOD) WILL BE USED. 9. FOR LANDSCAPING COVERAGE USE STENOTAPHRUM SECUNDATUM "FLORATAM" GRASS. KEY MAP SCALE: 1:250 LANDSCAPING REQUIREMENTS TREES SHRUBS 1 TREE AND 3 SHRUBS FOR EVERY 3,000 SF OF LOT AREA — 90,1 69 SF 30 90 AT LEAST 1 TREE AND 3 SHRUBS FOR EACH 300 SF OF REQUIRED LANDSCAPED BUFFER 270 LF OF NON —DRIVEWAY FRONTAGE ON NE 5TH ST FOR 10' BUFFER REQUIRES 2,700 SF OF LANDSCAPED AREA 9 27 220 LF OF NON —DRIVEWAY FRONTAGE ON NE 3RD AVE FOR 10' BUFFER REQUIRES 2,200 SF OF LANDSCAPED AREA 7 22 270 LF OF NON —DRIVEWAY FRONTAGE ON NE 4TH FOR 10' BUFFER REQUIRES 2,700 SF OF LANDSCAPED AREA 9 27 300 LF OF FRONTAGE ON NE 2ND AVE FOR 10' BUFFER REQUIRES 3,000 SF OF LANDSCAPE AREA 10 30 18 SF OF LANDSCAPING FOR EVERY PARKING SPACE — 1 TREE AND 3 SHRUBS FOR EVERY 72 SF OF LANDSCAPING — 50 15 45 PROPOSED PARKING SPACES LANDSCAPE ISLANDS MIN 5' X 150 EVERY 10 SPACES MA. UNINTERRUPTED SPACES 12 MULTIFAMILY TWO TO FOUR BEDROOMS (3 TREES PER UNIT) — 22 UNITS 70 210 MULTIFAMILY ONE BEDROOM (2 TREES PER UNIT) 0 0 TOTAL: 30 90 NOTES: LANDSCAPING REQUIREMENT WILL REQUIRE MINIMUM LANDSCAPING BASED ON 1 TREE AND 3 SHRUBS FOR EVERY 3,000 SF OF LOT AREA ( IN FEET ) 1 inch = 20 ft. MATCHLINE SEE SHEET C301 MATCHLINE SHEET C302 NE 3RD STREET NE 4TH STREET GRAPHIC SCALE 20 0 10 20 40 80 Z m Tw N v D m Z C m A LEGEND PROPOSED PALM TREE (27 PROVIDED) �6) PROPOSED TREE (13 PROVIDED) 0 PROPOSED SHRUB (166 PROVIDED) EXISTING PALM TREE TO REMAIN (2 TOTAL) EXISTING TREE TO REMAIN (11 TOTAL) EXISTING PINE TREE TO REMAIN (1 TOTAL) NOTE 1. THERE ARE EXISTING TREES ONSITE THAT WILL MEET SOME OF THE LANDSCAPING REQUIREMENT. SINCE THERE IS NOT A TREE SURVEY, THIS WILL BE FIELD ADJUSTED. 2. THIS PLAN FOR SITE APPROVAL AND ONLY INDICATES THE LOCATION AND TYPE OF PROPOSED LANDSCAPING. THE SELECTED PLANT TO BE INSTALLED WILL HAVE TO MEET THE CITY OF OKEECHOBEE'S DIVISION 4 LANDSCAPE CODE FOR TYPE AND SIZE OF PLANTS INSTALLED. 3. THE NORTH PARCEL HAS ALREADY BEEN THROUGH SITE PLAN AND WAS PREVIOUSLY APPROVED AND CERTIFIED PRIOR TO CERTIFICATE OF OCCUPANCY FOR THE LATEST CITY OF OKEECHOBEE TRC APPROVAL. 4. CONSIDERATION WILL BE MADE TO PROTECT THE OVERHEAD UTILITY LINES FROM MATURE TREE GROWTH. 5. PLANTINGS WILL BE ELECTED FROM SOUTH FLORIDA WATER MANAGEMENT DISTRICT'S XERISCAPE PLAN GUIDE, WITH AT LEAST 75% OF THE TOTAL REQUIRED PLANS BEING NATIVE VERY DROUGHT TOLERANT SPECIES AS LISTED IN THAT PLANT GUIDE. 6. TREES SHALL BE AT LEAST 10' HIGH AND 2" DIAMETER MEASURED 4' ABOVE GROUND LEVEL AT THE TIME OF PLANTING. 7.LANDSCAPE AREAS WILL BE MULCH AROUND TREES AND SHRUBS. 8. FOR A DIVERSITY OF PLANTINGS, CABBAGE PALM (CAULIS PALMA) AND PINDO PALM (PINDO PALMA) WILL BE USE IN PLACES OTHER THAN DESCRIBE BELOW: a. FOR TREES UNDER POWER LINES, SILVER BUTTONWOOD (ARGENTUM BUTTONWOOD), AND CRAPE MYRTLE (CRAPE MYTUS) WILL BE USED. b. FOR SHADE IN THE PARKING AREAS, LIVE OAK (VIVAMUS QUERCUS), BLACK OLIVE (OLIVAE NIGRAE) OR GREEN BUTTONWOOD (GREEN BUTTONWOOD) WILL BE USED. 9. FOR LANDSCAPING COVERAGE USE STENOTAPHRUM SECUNDATUM "FLORATAM" GRASS. KEY MAP SCALE: 1:250 LANDSCAPING REQUIREMENTS TREES SHRUBS 1 TREE AND 3 SHRUBS FOR EVERY 3,000 SF OF LOT AREA — 94,525 SF 32 96 AT LEAST 1 TREE AND 3 SHRUBS FOR EACH 300 SF OF REQUIRED LANDSCAPED BUFFER 270 LF OF NON —DRIVEWAY FRONTAGE ON NE 5TH ST FOR 10' BUFFER REQUIRES 2,700 SF OF LANDSCAPED AREA 9 27 220 LF OF NON —DRIVEWAY FRONTAGE ON NE 3RD AVE FOR 10' BUFFER REQUIRES 2,200 SF OF LANDSCAPED AREA 10 30 270 LF OF NON —DRIVEWAY FRONTAGE ON NE 4TH FOR 10' BUFFER REQUIRES 2,700 SF OF LANDSCAPED AREA 9 27 300 LF OF FRONTAGE ON NE 2ND AVE FOR 10' BUFFER REQUIRES 3,000 SF OF LANDSCAPE AREA 7 22 18 SF OF LANDSCAPING FOR EVERY PARKING SPACE — 1 TREE AND 3 SHRUBS FOR EVERY 72 SF OF LANDSCAPING — 50 15 45 PROPOSED PARKING SPACES LANDSCAPE ISLANDS MIN 5' X 150 EVERY 10 SPACES MA. UNINTERRUPTED SPACES 12 MULTIFAMILY TWO TO FOUR BEDROOMS (3 TREES PER UNIT) — 70 210 22 UNITS MULTIFAMILY ONE BEDROOM (2 TREES PER UNIT) 0 0 TOTAL: 32 96 NOTES: LANDSCAPING REQUIREMENT WILL REQUIRE MINIMUM LANDSCAPING BASED ON 1 TREE AND 3 SHRUBS FOR EVERY 3,000 SF OF LOT AREA ( IN FEET ) 1 inch = 20 ft. I:�a•�yn��nrar��naarzynn�mrel INDIO