Loading...
2023-02-16 V. A. 23-001-TRC 11/17/22 Minor Subdivision PlansSHEET INDEX: SHEET C000: TITLE SHEET SHEET C001: GENERAL NOTES & SPECIFICATIONS SHEET CD001: BLOCK 110 EXISTING CONDITION, DEMOLITION,AND SEDIMENT CONTROL PLAN SHEET CDO02: BLOCK 121 EXISTING CONDITION, DEMOLITION,AND SEDIMENT CONTROL PLAN SHEET C201: BLOCK 110 HORIZONTAL CONTROL, STRIPPING AND SIGNAGE PLAN SHEET C202: BLOCK 121 HORIZONTAL CONTROL, STRIPPING AND SIGNAGE PLAN SHEET C301: BLOCK 110 PAVING, GRADING & DRAINAGE PLAN SHEET C302: BLOCK 121 PAVING, GRADING & DRAINAGE PLAN SHEET C401: BLOCK 110 OVERALL SEWERLINE PLAN SHEET C402: BLOCK 121 OVERALL SEWERLINE PLAN SHEET C501: BLOCK 110 OVERALL WATERLINE PLAN SHEET C502: BLOCK 121 OVERALL WATERLINE PLAN SHEET C600: DETAILS — 1 SHEET C601: DETAILS — 2 SHEET C602: DETAILS 3 SHEET C603: DETAILS — 4 SHEET C604: DETAILS — 5 SHEET C701: BLOCK 110 LANDSCAPING PLAN SHEET C702: BLOCK 121 LANDSCAPING PLAN MINOR SUBDIVISION GLENWOOD PARK LOCATED IN SECTION 15, TOWNSHIP 37 SOUTH., RANGE 35 EAST OKEECHOBEE CITY, FLORIDA III CALL 48 HOURS BEFORE YOU DIG IN FLORIDA, IT'S THE LAW • r , r of Florida, Inc. cam`21 rIR`—�j GRAPHIC SCALE 60 0 30 60 120 240 ( IN FEET ) 1 inch = 60 ft. .g 1 n NW 7m St NW Sth St NW Ath S1 NW 3rd St NW 1st SI Park St n SITE 0 � Cypress ` Quarters R NW gill S NW Bill Sl ` NW 71h St NW 7m 5; s NW 6th St NW Sth St NW Ath St NF Am St n NW 3rd St i ., M4 2nd St a �d NW Park St Okeechobee a5 SE Ath St m SW 6th St SE 6th St TN 81h St sw gm se _ y3 N wi I (ith St 5'N 18-h S f a f y a t� Walmart Supercenter Q N y a SW 2" St NoIR R_ & SE 26th St 2 D SW 32nd St N LOCATION MAP Comer St SET SE 25m Or SE 27th St y I SE�n SF 32nd St_ s�rrr VICINITY MAP N.T.S. N.T.S. LOT 1 THROUGH 12, INCLUSIVELY, BLOCK 110, CITY OF OKEECHOBEE, PLAT BOOK 5, PAGE 5, OKEECHOBEE COUNTY, FLORIDA. LOT 1 THROUGH 12, INCLUSIVELY, BLOCK 121, CITY OF OKEECHOBEE, PLAT BOOK 5, PAGE 5, OKEECHOBEE COUNTY, FLORIDA. BEACH PIERCE )RT ST. LUCIE TUART JUPITER WEST PALM B 1. THE SURVEY DATE IS MARCH 18, 2021. 2. THIS IS A BOUNDARY SURVEY, AS DEFINED IN CHAPTER 5J-17.050(11) OF THE FLORIDA ADMINISTRATIVE CODE. 3, THIS SURVEY MAP AND REPORT OR THE COPIES THEREOF ARE NOT VALID WITHOUT THE SIGNATURE AND THE ORIGINAL SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER. 4. ADDITIONS OR DELETIONS TO SURVEY MAPS OR REPORTS BY OTHER THAN THE SIGNING PARTY OR PARTIES IS PROHIBITED WITHOUT WRITTEN CONSENT OF THE SIGNING PARTY OR PARTIES. 5. BEARINGS SHOWN HEREON ARE BASED ON GRID NORTH, AND ARE REFERENCED TO THE FLORIDA STATE PLANE COORDINATE SYSTEM, EAST ZONE, NORTH AMERICAN DATUM OF 1983, 2011 ADJUSTMENT, THE BEARING BASE FOR THIS SURVEY IS THE CENTERLINE OF NORTHEAST 4TH STREET BETWEEN BLOCKS 110 AND 121, SAID LINE BEARS N 89°47'50" E AND ALL OTHER BEARINGS ARE RELATIVE THERETO. 6. THIS SURVEY DOES NOT HAVE THE BENEFIT OF A CURRENT TITLE COMMITMENT, OPINION, OR ABSTRACT. DURING THE COURSE OF THE SURVEY SOME SEARCHES OF THE PUBLIC RECORDS WERE MADE, BUT THESE SEARCHES WERE NOT EXHAUSTIVE AND SHOULD NOT BE CONSIDERED A SUBSTITUTE FOR A PROPER TITLE COMMITMENT, OPINION, OR ABSTRACT OBTAINED FROM A TITLE AGENCY OR OTHER TITLE PROFESSIONAL. 7. THE LEGAL DESCRIPTION OF THE LAND CONTAINED IN THIS BOUNDARY SURVEY IS BASED ON THE DESCRIPTION RECORDED IN OFFICIAL RECORDS BOOK 786, PAGE 1593, AND OFFICIAL RECORDS BOOK 816, PAGE 970 AS RECORDED IN THE PUBLIC RECORDS OF OKEECHOBEE COUNTY, FLORIDA. 8. THIS SURVEY DELINEATES THE LOCATIONS OF THE LEGAL DESCRIPTIONS ON THE GROUND, BUT DOES NOT DETERMINE OWNERSHIP OR PROPERTY RIGHTS. 9. ADJOINING PROPERTY INFORMATION WAS OBTAINED FROM OKEECHOBEE COUNTY PROPERTY APPRAISER OFFICE AND PER PLAT. 10. AERIAL IMAGERY SHOWN HEREON WAS OBTAINED FROM THE LAND BOUNDARY INFORMATION SYSTEM (LABINS) DATED 2018 AND IS SHOWN FOR INFORMATIONAL PURPOSES ONLY. 11. SUBJECT PROPERTY IS LOCATED IN FLOOD ZONE X PER FEMA MAP NUMBER 12093C, PANEL NUMBER 0485C, WITH AN EFFECTIVE DATE OF 07/16/15. H GENERAL NOTES EROSION AND SEDIMENTATION CONTROL NOTES - (CONTINUED) CONTINUED: 1. CONTRACTOR IS RESPONSIBLE FOR CHECKING ACTUAL SITE CONDITIONS BEFORE STARTING CONSTRUCTION. 2. ANY DISCREPANCIES ON THE DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER BEFORE COMMENCING WORK. 3. CONTRACTOR SHALL OBTAIN ALL REQUIRED BUILDING PERMITS BEFORE COMMENCING WORK. 4. CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATION OF ALL EXISTING UTILITIES. THE CONTRACTOR SHALL CONTACT ALL CONCERNED UTILITIES AT LEAST 48 HOURS IN ADVANCE FOR CONSTRUCTION OPERATIONS. 5. NO FIELD CHANGES OR DEVIATIONS FROM DESIGN TO BE MADE WITHOUT PRIOR APPROVAL OF THE ENGINEER. 6. ALL CONSTRUCTION SHALL BE COMPLETED IN ACCORDANCE WITH THE APPLICABLE ORDINANCES OF CITY OF OKEECHOBEE, FLORIDA. 7. CONTRACTOR SHALL SUPPLY DENSITY TESTS TO ENGINEER ON ALL SUB -GRADE AND BASE. TESTS SHALL BE PREPARED PER AASHTO T-180 METHOD. 8. SLOPE GRADES FROM ELEVATIONS SHOWN TO EXISTING GRADE AT PROPERTY LINE. 9. ENGINEER SHALL BE NOTIFIED AT LEAST 48 HOURS IN ADVANCE FOR ANY INSPECTION. 10. ALL TRAFFIC CONTROL DEVICES SHALL BE IN ACCORDANCE WITH M.U.T.C.D. STANDARDS. 11. EROSION AND SEDIMENTATION CONTROL TECHNIQUES SHALL BE INCORPORATED DURING CONSTRUCTION AS FOLLOWS: (1) SILT SCREENS SHALL BE MAINTAINED AT THE PROJECT PERIMETER. (2) NO OFF -SITE DISCHARGES SHALL OCCUR DURING CONSTRUCTION. IN THE EVENT DISCHARGE IS REQUIRED, HAY BALES AND/OR TURBIDITY CURTAINS SHALL BE INCORPORATED AT THE DISCHARGE POINT AS NECESSARY TO CONTROL TURBIDITY. EROSION AND SEDIMENTATION CONTROL NOTES CONSTRUCTION ACTIVITIES CAN RESULT IN THE GENERATION OF SIGNIFICANT AMOUNTS OF POLLUTANTS WHICH MAY REACH SURFACE OR GROUND WATERS. ONE OF THE PRIMARY POLLUTANTS OF SURFACE WATERS IS SEDIMENT DUE TO EROSION. EXCESSIVE QUANTITIES OF SEDIMENT WHICH REACH WATER BODIES OF FLOODPLAINS HAVE BEEN SHOWN TO ADVERSELY AFFECT THEIR PHYSICAL, BIOLOGICAL AND CHEMICAL PROPERTIES. TRANSPORTED SEDIMENT CAN OBSTRUCT STREAM CHANNELS, REDUCE HYDRAULIC CAPACITY OF WATER BODIES OF FLOODPLAINS, REDUCE THE DESIGN CAPACITY OF CULVERTS AND OTHER WORKS, AND ELIMINATE ETHIC INVERTEBRATES AND FISH SPAWNING SUBSTRATES BY SILTATION. EXCESSIVE SUSPENDED SEDIMENTS REDUCE LIGHT PENETRATION AND THEREFORE, REDUCE PRIMARY PRODUCTIVITY. MINIMUM STANDARDS: 1. SEDIMENT BASIN AND TRAPS, PERIMETER DIKES, SEDIMENT BARRIERS AND OTHER MEASURES INTENDED TO TRAP SEDIMENT SHALL BE CONSTRUCTED AS A FIRST STEP IN ANY LAND -DISTRIBUTING ACTIVITY AND SHALL BE MADE FUNCTIONAL BEFORE UNSLOPE LAND DISTURBANCE TAKES PLACE. 2. ALL SEDIMENT CONTROL MEASURES ARE TO BE ADJUSTED TO MEET FIELD CONDITIONS AT THE TIME OF CONSTRUCTION AND BE CONSTRUCTED PRIOR TO ANY GRADING OR DISTURBANCE OF EXISTING SURFACE MATERIAL ON BALANCE OF SITE. PERIMETER SEDIMENT BARRIERS SHALL BE CONSTRUCTED TO PREVENT SEDIMENT OR TRASH FROM FLOWING OR FLOATING ON TO ADJACENT PROPERTIES. 3. PERMANENT OR TEMPORARY SOIL STABILIZATION SHALL BE APPLIED TO DENUDED AREAS WITHIN SEVEN DAYS AFTER FINAL GRADE IS REACHED ON ANY PORTION OF THE SITE. TEMPORARY SOIL STABILIZATION SHALL BE APPLIED WITHIN SEVEN DAYS TO DENUDED AREAS THAT MAY NOT BE AT FINAL GRADE BUT WILL REMAIN UNDISTURBED FOR LONGER THAN 30 DAYS. PERMANENT STABILIZATION SHALL BE APPLIED TO AREAS THAT ARE TO BE LEFT UNDISTURBED FOR MORE THAN ONE YEAR. 4. DURING CONSTRUCTION OF THE PROJECT, SOIL STOCKPILES SHALL BE STABILIZED OR PROTECTED WITH SEDIMENT TRAPPING MEASURES. THE APPLICANT IS RESPONSIBLE FOR THE TEMPORARY PROTECTION AND PERMANENT STABILIZATION OF ALL SOIL STOCKPILES ON SITE AS WELL AS SOIL INTENTIONALLY TRANSPORTED FROM THE PROJECT SITE. 5. A PERMANENT VEGETATIVE COVER SHALL BE ESTABLISHED ON DENUDED AREAS NOT OTHERWISE PERMANENTLY STABILIZED. PERMANENT VEGETATION SHALL NOT BE CONSIDERED ESTABLISHED UNTIL A GROUND COVER IS ACHIEVED THAT, IN THE OPINION OF THE REVIEWER, IS UNIFORM, MATURE ENOUGH TO SURVIVE AND WILL INHIBIT EROSION. 6. STABILIZATION MEASURES SHALL BE APPLIED TO EARTHEN STRUCTURES SUCH AS DAMS, DIKES AND DIVERSIONS IMMEDIATELY AFTER INSTALLATION. 7. SURFACE RUNOFF FROM DISTURBED AREAS THAT IS COMPRISED OF FLOW FROM DRAINAGE AREAS GREATER THAN OR EQUAL TO THREE ACRES SHALL BE CONTROLLED BY A SEDIMENT BASIN. THE SEDIMENT BASIN SHALL BE DESIGNED AND CONSTRUCTED TO ACCOMMODATE THE ANTICIPATED SEDIMENT LOADING FROM THE LAND -DISTURBING ACTIVITY. THE OUTFALL DEVICE OR SYSTEM DESIGN SHALL TAKE INTO ACCOUNT THE TOTAL DRAINAGE AREA FLOWING THROUGH THE DISTURBED AREA TO BE SERVED BY THE BASIN. 8. AFTER ANY SIGNIFICANT RAINFALL, SEDIMENT CONTROL STRUCTURES WILL BE INSPECTED FOR INTEGRITY. ANY DAMAGED DEVICES SHALL BE CORRECTED IMMEDIATELY. 9. CONCENTRATED RUNOFF SHALL NOT FLOW DOWN CUT OR FILL SLOPES UNLESS CONTAINED WITHIN AN ADEQUATE TEMPORARY OR PERMANENT CHANNEL, FLUME OR SLOPE DRAIN STRUCTURE. 10. WHENEVER WATER SEEPS FROM A SLOPE FACE, ADEQUATE DRAINAGE OR OTHER PROTECTION SHALL BE PROVIDED. 11. SEDIMENT WILL BE PREVENTED FROM ENTERING ANY STORM DRAIN SYSTEM, DITCH OR CHANNEL. ALL STORM SEWER INLETS THAT ARE MADE OPERABLE DURING CONSTRUCTION SHALL BE PROTECTED SO THAT SEDIMENT -LADEN WATER CANNOT ENTER THE CONVEYANCE SYSTEM WITHOUT FIRST BEING FILTERED OR OTHERWISE TREATED TO REMOVE SEDIMENT. 12. BEFORE TEMPORARY OR NEWLY CONSTRUCTED STORMWATER CONVEYANCE CHANNELS ARE MADE OPERATIONAL, ADEQUATE OUTLET PROTECTION AND ANY REQUIRED TEMPORARY OR PERMANENT CHANNEL LINING SHALL BE INSTALLED IN BOTH THE CONVEYANCE CHANNEL AND RECEIVING CHANNEL. 13. WHEN WORK IN A LIVE WATERCOURSE IS PERFORMED, PRECAUTIONS SHALL BE TAKEN TO MINIMIZE ENCROACHMENT, CONTROL SEDIMENT TRANSPORT AND STABILIZE THE WORK AREA TO THE GREATEST EXTENT POSSIBLE DURING CONSTRUCTION. NONERODIBLE MATERIAL SHALL BE USED FOR THE CONSTRUCTION OF CAUSEWAYS AND COFFERDAMS. EARTHEN FILL MAY BE USED FOR THESE STRUCTURES IF ARMORED BY NONERODIBLE COVER MATERIALS. 14. WHEN A LIVE WATERCOURSE MUST BE CROSSED BY CONSTRUCTION VEHICLES, A TEMPORARY STREAM CROSSING CONSTRUCTED OF NONERODIBLE MATERIAL SHALL BE PROVIDED. il.'�I.IS1a11] 117:1"1=1`�16] : i : Ia:ZK9mJd.9a 11110l11 1a 0111/_1.11WA9111111 II■.mIINA'/_101■:111101 Mlll �I 10Mi N I■dK6lPill ;01m&*`Wolf MLAaaIaI 16. PERIODIC INSPECTION AND MAINTENANCE OF ALL SEDIMENT CONTROL STRUCTURES MUST BE PROVIDED TO ENSURE INTENDED PURPOSE IS ACCOMPLISHED. THE DEVELOPER, OWNER AND/OR CONTRACTOR SHALL BE CONTINUALLY RESPONSIBLE FOR ALL SEDIMENT LEAVING THE PROPERTY. SEDIMENT CONTROL MEASURES SHALL BE IN WORKING CONDITION AT THE END OF EACH WORKING DAY. 17. UNDERGROUND UTILITY LINES SHALL BE INSTALLED IN ACCORDANCE WITH THE FOLLOWING STANDARDS IN ADDITION TO OTHER APPLICABLE CRITERIA: A. NO MORE THAN 500 LINEAR FEET OF TRENCH MAY BE OPENED AT ONE TIME. B. EXCAVATED MATERIAL SHALL BE PLACED ON THE UPHILL SIDE OF TRENCHES. C. EFFLUENT FROM DEWATERING OPERATIONS SHALL BE FILTERED OR PASSED THROUGH AN APPROVED SEDIMENT TRAPPING DEVICE, OR BOTH, AND DISCHARGED IN A MANNER THAT DOES NOT ADVERSELY AFFECT FLOWING STREAMS OR OFF -SITE PROPERTY. D. RESTABILIZATION SHALL BE ACCOMPLISHED IN ACCORDANCE WITH THESE REGULATIONS. ENGINEER OF RECORD INSPECTION REQUIREMENTS F.B.V. DENSITY L.B.R. THICKNESS MAX. SPACING MAX. SPACING MAX. SPACING MAX. SPACING LINEAR SQUARE LINEAR SQUARE LINEAR SQUARE LINEAR SQUARE FEET FEET FEET FEET FEET FEET FEET FEET COMPACTED OR STABILIZED GRADE 200 5,000 200 5,000 200 5,000 300 10,000 ROCK BASE ---- ---- 300 10,000 300 10,000 300 10,000 SHELL ROCK ---- ---- 300 10,000 ---- ---- 300 10,000 ASPHALT ---- ---- ---- ---- --- PER PER INSP. I INSP. TESTING SHALL BE TAKEN IN A STAGGERED SAMPLING PATTERN FROM A POINT 121, INSIDE THE L EDGE OF THE ITEM TESTED, TO THE CENTER, TO A POINT INSIDE OF THE RIGHT EDGE FT 18. WHERE CONSTRUCTION VEHICLE ACCESS ROUTES INTERSECT PAVED PUBLIC ROADS, PROVISIONS SHALL BE MADE TO MINIMIZE THE THE CONTRACTOR SHALL COMPLY WITH CHAPTER 90-96, LAWS OF FLORIDA, WHICH REQUIRES THE CONTRACTOR PERFORMING TRENCH TRANSPORT OF SEDIMENT BY TRACKING ONTO THE PAVED SURFACE, WHERE SEDIMENT IS TRANSPORTED ONTO A PUBLIC ROAD SURFACE EXCAVATIONS OVER FIVE FEET IN DEPTH COMPLY WITH ALL APPLICABLE TRENCH SAFETY STANDARDS AND SHORING REQUIREMENTS AS WITH CURBS AND GUTTERS, THE ROAD SHALL BE CLEANED THOROUGHLY AT THE END OF EACH DAY. SEDIMENT SHALL BE REMOVED SET FORTH IN THE OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION'S (OSHA) EXCAVATION AND SAFETY STANDARDS, 29 C.F.R. FROM THE ROADS BY SHOVELING OR SWEEPING AND TRANSPORTED TO A SEDIMENT CONTROL DISPOSAL AREA. STREET WASHING SHALL 19926.650, SUB -PART P AND INCORPORATED AS THE STATE OF FLORIDA STANDARD, AS REVISED AND/OR UPDATED. THE COST OF BE ALLOWED ONLY AFTER SEDIMENT IS REMOVED IN THIS MANNER. THIS PROVISION SHALL APPLY TO INDIVIDUAL SUBDIVISION LOTS AS COMPLIANCE WITH THIS REQUIREMENT SHALL BE INCLUDED AS A SEPARATE LINE ITEM ON THE CONTRACTOR'S BID. OTHERWISE, WELL AS TO LARGER LAND- DISTRIBUTING ACTIVITIES. CONTRACTOR CERTIFIES THAT THE COST OF COMPLIANCE IS INCLUDED IN THE UNIT COST OF ALL ITEMS OF WORK TO WHICH THIS REQUIREMENT APPLIES. 19. ALL TEMPORARY EROSION AND SEDIMENT CONTROL MEASURES SHALL BE REMOVED WITHIN 30 DAYS AFTER FINAL SITE STABILIZATION OR AFTER THE TEMPORARY MEASURES ARE NO LONGER NEEDED, IN THE OPINION OF THE REVIEWER. DISTURBED SOIL AREAS RESULTING FROM THE DISPOSITION OF TEMPORARY MEASURES SHALL BE PERMANENTLY STABILIZED TO PREVENT FURTHER EROSION AND SEDIMENTATION. 20. PROPERTIES AND WATERWAYS DOWNSTREAM FROM CONSTRUCTION SITE SHALL BE PROTECTED FROM SEDIMENT DISPOSITION AND EROSION. ■ ,:I_G9■ 1•,CZ■111=■lG' .`P.[0lll■ 1•.l=■]■7_1.»Il•II<K■]R M@a[a1■IRVi91P.<KNaU`I1[NIt■]i7_Z■l:■,:I_G9M 22. EROSION CONTROL DESIGN AND CONSTRUCTION SHALL FOLLOW THE REQUIREMENTS IN INDEX NOS. 101, 102 AND 103 OF FDOT ROADWAY AND TRAFFIC DESIGN STANDARDS. 23. THE REVIEWER MAY APPROVE MODIFICATIONS OR ALTER PLANS TO THESE EROSION CONTROL CRITERIA DUE TO SITE SPECIFIC CONDITIONS. EARTHWORK AND DRAINAGE SPECIFICATION 1 . CLEARING AND GRUBBING: CLEARING AND GRUBBING SHALL BE PERFORMED WITHIN THE LIMITS OF THE PROJECT WORK IN ACCORDANCE WITH SECTION 110, FLORIDA DEPARTMENT OF TRANSPORTATION (FDOT) SPECIFICATIONS. THIS ITEM SHALL INCLUDE, BUT IS NOT LIMITED TO, THE COMPLETE REMOVAL AND LEGAL DISPOSAL OF ALL TREES, BRUSH, STUMPS, ROOTS, GRASS, WEEDS, RUBBISH AND OTHER UNDESIRABLE MATERIAL TO A DEPTH OF 18 INCHES BELOW NATURAL GROUND OR PROPOSED FINISHED GRADE, WHICHEVER IS LOWER. THE AREAS TO BE CLEARED GENERALLY CONSIST OF THE ENTIRE SITE WITH THE EXCEPTION OF AREAS SPECIFICALLY NOTED ON THE LANDSCAPE PLANS AS PRESERVE AREAS OR AS AREAS TO REMAIN UN -CLEARED. CARE SHALL BE TAKEN TO INSURE THAT NO PRESERVE AREAS OR WETLAND AREAS ARE IMPACTED BY THE CLEARING OPERATION. PRIOR TO INITIATING THE CLEARING OPERATION, ALL ADJACENT WETLAND AND PRESERVE AREAS SHALL BE MARKED AND FLAGGED IN ACCORDANCE WITH THE CITY OF OKEECHOBEE AND SOUTH FLORIDA WATER MANAGEMENT DISTRICT (SFWMD) REQUIREMENTS ALL SUCH AREAS IMMEDIATELY ADJACENT TO THE CLEARING OPERATION SHALL ALSO BE PROTECTED BY THE INSTALLATION OF TEMPORARY SILT BARRIERS IN ACCORDANCE WITH THE REQUIREMENTS OF THE CITY OF OKEECHOBEE AND THE SFWMD. FURTHER EROSION CONTROL SHALL BE ACCOMPLISHED BY SEEDING AND MULCHING ALL DISTURBED AREAS AS SOON AS THEY ARE AT FINAL GRADE, PER THE SPECIFICATIONS FOR SEEDING AND MULCHING FOUND ELSEWHERE ON THIS SHEET. ALL MATERIAL SHALL BE REMOVED FROM THE SITE AND SHALL BE LEGALLY DISPOSED OF IN ACCORDANCE WITH ALL LOCAL, STATE AND FEDERAL REQUIREMENTS. 2.EARTHWORK AND GRADING: ALL EARTHWORK AND GRADING SHALL BE PERFORMED AS REQUIRED TO ACHIEVE THE FINAL GRADES, TYPICAL SECTIONS AND ELEVATIONS SHOWN ON THE PLANS. IN ALL OTHER RESPECTS, MATERIALS AND CONSTRUCTION METHODS FOR EARTHWORK, EMBANKMENT, EXCAVATION AND GRADING SHALL CONFORM TO THE REQUIREMENTS OF FDOT SPECIFICATIONS, SECTION 120. ANY PLASTIC OR OTHERWISE UNDESIRABLE MATERIAL WITHIN 36 INCHES OF FINISHED ROAD GRADE SHALL BE REMOVED AND REPLACED WITH SUITABLE MATERIAL. THE CONTRACTOR SHALL ALSO REFER TO THE SOILS REPORT, IF AVAILABLE. THE SPECIFICATIONS AND RECOMMENDATIONS INCLUDED IN THAT REPORT SHALL BE CONSIDERED AS A PART OF THESE PLANS AND SPECIFICATIONS. SHOULD THERE BE ANY CONFLICT BETWEEN THAT DOCUMENT AND ANY REQUIREMENTS OF THESE DRAWINGS OR SPECIFICATIONS, THE MOST RESTRICTIVE REQUIREMENT SHALL GOVERN. C1!lau►[e>■IINA=91•/0a0111611 ALL AREAS PROPOSED FOR PAVING SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE DESIGN GRADES AND TYPICAL SECTIONS SHOWN ON THE DRAWINGS, AND IN CONFORMANCE TO THE REQUIREMENTS OF THE CITY OF OKEECHOBEE AND FLORIDA DEPARTMENT OF TRANSPORTATION. A. ASPHALT: PRIME COAT AND TACK COAT FOR BASE COURSE AND BETWEEN LIFTS OF ASPHALT SHALL CONFORM TO THE REQUIREMENTS OF SECTIONS 300-1 THROUGH 300-7 OF THE FDOT SPECIFICATIONS. PRIME COAT SHALL BE APPLIED AT A RATE OF 0.25 GALLONS PER SQUARE YARD AND TACK COAT AT A RATE OF 0.10 GALLONS PER SQUARE YARD, UNLESS OTHERWISE APPROVED BY THE ENGINEER. ASPHALT SURFACE COURSE THICKNESS AND MATERIAL SHALL BE AS SHOWN ON THE TYPICAL SECTIONS AND SHALL IN ALL WAYS CONFORM TO THE REQUIREMENTS OF FDOT. B. BASE: LIMEROCK BASE MATERIAL SHALL BE COMPACTED TO 98% OF MAXIMUM DENSITY PER AASHTO T-180. ALL LIMEROCK SHALL MEET THE MINIMUM REQUIREMENTS OF FDOT SECTION 911. AS AN ALTERNATE, CEMENTED COQUINA CONFORMING TO FDOT SECTION 915 MAY BE SUBSTITUTED AND SHALL BE SUBJECT TO THE COMPACTION SPECIFICATIONS DETAILED ABOVE AND INCLUDED IN THE SOILS ENGINEER'S REPORT. C. SUB -GRADE: SUB -GRADE SHALL BE COMPACTED TO 98% OF MAXIMUM DENSITY PER AASHTO T-180, AND STABILIZED TO A MINIMUM FBV OF 50PS1. SUB -GRADE SHALL BE THOROUGHLY ROLLED WITH A PNEUMATIC TIRED ROLLER PRIOR TO SCHEDULING ANY SUB -GRADE INSPECTION. D. VALLEY GUTTER/ F-CURB/D-CURB/FLUSH CURB: SHALL BE CONSTRUCTED PER THE TYPICAL SECTION BY EXTRUDING MACHINE OR FORMS AS SHOWN ON THE PLANS. MINIMUM CONCRETE COMPRESSIVE STRENGTH SHALL BE 3,000PSI AFTER 28 DAYS. SUB -GRADE SHALL BE MOISTENED AT THE TIME CONCRETE IS PLACED TO INSURE A UNIFORMLY DAMP SURFACE. READY -MIX CONCRETE SHALL HAVE A SLUMP OF BETWEEN 2 AND 4 INCHES. NO WATER SHALL BE ADDED TO INCREASE WORKABILITY. TEST CYLINDERS SHALL BE MADE FOR THE STRENGTH TESTING OF EACH BATCH OF CONCRETE FOR AT LEAST 7 AND 28 DAY TESTING. E. SOD: A MINIMUM OF A TWO -FOOT WIDE STRIP OF SOD, OR AS OTHERWISE SHOWN ON THE PLANS, SHALL BE PLACED ALONG THE BACK OF CURB OF ALL CONSTRUCTED PAVEMENT TO AID IN PREVENTION OF EROSION AND SOIL STABILITY. SOD SHALL BE PLACED IN CONFORMANCE TO FDOT SECTION 570, 575 AND 981. GENERALLY, THE SODDING REQUIREMENTS SHALL BE AS SPECIFIED ON THE LANDSCAPE PLANS, PREPARED BY OTHERS. F. SEED, FERTILIZE AND MULCH: ALL DISTURBED AREAS SHALL BE STABILIZED WITH SEED, FERTILIZER AND MULCH UPON COMPLETION AND ACCEPTANCE BY ENGINEER OF FINAL GRADING. SEED, FERTILIZER AND MULCH SHALL BE IN CONFORMANCE TO FDOT SECTIONS 570, 575 AND 981. THE CONTRACTOR IS RESPONSIBLE FOR ESTABLISHING A STAND OF GRASS SUFFICIENT TO PREVENT EROSION PRIOR TO REMOVAL OF THE TEMPORARY SILT FENCES. THIS APPLIES ONLY TO THOSE AREAS NOT COVERED BY THE SODDING SPECIFIED IN THE LANDSCAPE PLANS, PREPARED BY OTHERS. G. TESTING: THE CONTRACTOR SHALL SECURE THE SERVICES OF AN APPROVED INDEPENDENT TESTING LABORATORY TO CONDUCT ALL REQUIRED TESTING ON SUB -GRADE, BASE, ASPHALT AND CONCRETE. LOCATIONS REQUIRED FOR THESE TESTS SHALL BE AS REQUIRED BY THE CITY OF OKEECHOBEE, AND/OR IN THE CASE OF THE TURN -LANE IMPROVEMENTS AS REQUIRED BY THE CITY OF OKEECHOBEE. AT A MINIMUM, TESTING SHALL BE AS RECOMMENDED BY FDOT. SHOULD ANY TESTS FAIL, CONTRACTOR SHALL AT HIS OWN EXPENSE, REPAIR THE DEFICIENCIES AND RETEST THE WORK UNTIL COMPLIANCE WITH THE SPECIFICATIONS IS DEMONSTRATED. H. TRAFFIC CONTROL: THE INSTALLATION OF TRAFFIC CONTROL DEVICES SHALL BE IN CONFORMANCE TO THE REQUIREMENTS OF THE MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES, THE CITY OF OKEECHOBEE. MAINTENANCE OF TRAFFIC DURING CONSTRUCTION SHALL BE AS REQUIRED BY FDOT. 4.DRAINAGE IMPROVEMENTS: ALL LABOR, MATERIALS AND CONSTRUCTION METHODS SHALL BE IN CONFORMANCE TO THE MINIMUM ENGINEERING AND CONSTRUCTION STANDARDS OF THE CITY OF OKEECHOBEE AND FDOT SPECIFICATIONS. TRENCH EXCAVATION AND BACK -FILLING OPERATIONS SHALL MEET OR EXCEED THE REQUIREMENTS OF FDOT SPECIFICATIONS, SECTION 125. THE CONTRACTOR SHALL PROVIDE THE NECESSARY BACK -FILL COMPACTION TESTING REQUIRED TO DEMONSTRATE COMPLIANCE WITH THIS SECTION. THE PIPE TRENCH SHALL BE DRY WHEN PIPE IS LAID AND THE PIPE SHALL BE BEDDED PER THE DETAILS AND PER FDOT SPECIFICATIONS. ENGINEER OF RECORD INSPECTION REQUIREMENTS CONTRACTOR TO CALL CONTRACT ENGINEER OF RECORD 48 HOURS ADVANCE FOR FOLLOWING INSPECTIONS: 1. PRECONSTRUCTION MEETING 2. DRAINAGE PIPE (UNCOVERED) 3. PAVEMENT SUBGRADE 4. PAVEMENT BASE 5. FINAL A. REINFORCED CONCRETE PIPE (RCP): RCP SHALL CONFORM TO THE REQUIREMENTS OF ASTM SPECIFICATIONS C-76, CLASS III, WALL THICKNESS "B", LATEST REVISION. ALL JOINTS SHALL BE SOIL -TIGHT. PIPE GASKET SHALL CONFORM TO FDOT SPECIFICATIONS, SECTION 942. B. CORRUGATED METAL PIPE (CMP): ALL CMP SHALL BE STEEL, ROUND, HELICAL -WOUND CORRUGATED PIPE CONFORMING TO AASHTO-M 36 AND FDOT SECTION 943. PIPE ENDS AT JOINTS SHALL BE REFORMED TO A MINIMUM OF 2 ANNULAR CORRUGATIONS FOR THE COMPLETE BAND WIDTH. ALL JOINTS SHALL BE SOIL -TIGHT. ALL CONNECTING BANDS SHALL BE CORRUGATED ANNULAR COUPLING BANDS. A NEOPRENE GASKET OF AT LEAST 7 INCHES WIDE BY 3/8 INCH THICK SHALL BE USED FOR ALL PIPES OF 36-INCH DIAMETER AND SMALLER. LARGER PIPE SIZES REQUIRE GASKETS OF AT LEAST 10-1/2 INCHES IN WIDTH. ALL CMP SHALL BE INSTALLED AT MAXIMUM LENGTHS TO REDUCE THE NUMBER OF JOINTS. C. CORRUGATED ALUMINUM PIPE (CAP): ALL CAP SHALL BE ALUMINUM ALLOY, ROUND, HELICAL -WOUND CORRUGATED PIPE CONFORMING TO AASHTO-M 196 AND FDOT SECTION 945. PIPE ENDS AT JOINTS SHALL BE REFORMED TO A MINIMUM OF 2 ANNULAR CORRUGATIONS FOR THE COMPLETE BAND WIDTH. ALL JOINTS SHALL BE SOIL -TIGHT. ALL CONNECTING BANDS SHALL BE CORRUGATED ANNULAR COUPLING BANDS. A NEOPRENE GASKET OF AT LEAST 7 INCHES WIDE BY 3/8 INCH THICK SHALL BE USED FOR ALL PIPES OF 36-INCH DIAMETER AND SMALLER. LARGER PIPE SIZES REQUIRE GASKETS OF AT LEAST 10-1/2 INCHES IN WIDTH. ALL CAP SHALL BE INSTALLED AT MAXIMUM LENGTHS TO REDUCE THE NUMBER OF JOINTS. D. CORRUGATED HIGH DENSITY POLYETHYLENE PIPE (HDPE): ALL HDPE PIPE SHALL BE RESIN CONFORMING TO ASTM D3350 MINIMUM CELL CLASSIFICATION 435400C, ROUND, ONLY ANNULAR CORRUGATIONS AND CONFORMING TO FDOT SECTION 948-2.3. ALL JOINTS SHALL BE SOIL -TIGHT. ALL CONNECTING BANDS SHALL BE CORRUGATED ANNULAR COUPLING BANDS. A NEOPRENE GASKET OF AT LEAST 7 INCHES WIDE BY 3/8 INCH THICK SHALL BE USED FOR ALL PIPES OF 36-INCH DIAMETER AND SMALLER. LARGER PIPE SIZES REQUIRE GASKETS OF AT LEAST 10-1/2 INCHES IN WIDTH. ALL HDPE SHALL BE INSTALLED AT MAXIMUM LENGTHS TO REDUCE THE NUMBER OF JOINTS. E. CONTECH A-2000 PVC DRAINAGE PIPE (A-2000): ALL A-2000 CORRUGATED PIPE WITH A SMOOTH INTERIOR SHALL CONFORM TO THE REQUIREMENTS OF ASTM DESIGNATION F949 & F794 DUAL WALL CORRUGATED PROFILE (DWCP) PIPE. PIPE AND FITTINGS SHALL BE HOMOGENEOUS THROUGHOUT AND FREE FROM VISIBLE CRACKS, HOLES, FOREIGN INCLUSIONS OR OTHER INJURIOUS DEFECTS. PIPE SHALL BE MANUFACTURED TO 46 PSI STIFFNESS WHEN TESTED IN ACCORDANCE WITH ASTM TEST METHOD D2412. THERE SHALL BE NO EVIDENCE OF SPLITTING, CRACKING OR BREAKING WHEN THE PIPE IS TESTED PER ASTM TEST METHOD D2412 AND F949 SECTION 7.5. THE PIPE SHALL BE MADE OF PVC COMPOUND HAVING A MINIMUM CELL CLASSIFICATION OF 12454B AS DEFINED IN ASTM SPECIFICATION D1784. F. PVC DRAINAGE PIPE: PVC DRAINAGE PIPE SHALL BE C-900 WITH PUSH -ON JOINTS (NO GLUED JOINTS) AND SHALL BE AS SPECIFIED FOR SANITARY SEWER CONSTRUCTION, EXCEPT THAT IT SHALL BE WHITE IN COLOR. ANY PORTION OF THE PVC STORM PIPE THAT MAY BE EXPOSED TO SUNLIGHT, SUCH AS ITS OUTLET TO THE DETENTION POND, SHALL BE PAINTED TO PROTECT IT FROM UV LIGHT. G. INLETS, MANHOLES, AND JUNCTION BOXES: ALL DRAINAGE INLETS, MANHOLES, AND JUNCTION BOXES SHALL BE PRECAST CONCRETE CONFORMING TO ASTM C-478 AND 64T. ALL CONCRETE SHALL HAVE NOT LESS THAN 4000-PSI COMPRESSIVE STRENGTH AT 28 DAYS. STRUCTURE SECTIONS SHALL BE JOINED WITH A MASTIC SEALING COMPOUND. THE REMAINING SPACE SHALL BE FILLED WITH THE CEMENT MORTAR AND FINISHED SO AS TO PRODUCE A SMOOTH CONTINUOUS SURFACE INSIDE AND OUTSIDE THE WALL SECTIONS. ALL OPENINGS IN PRECAST STRUCTURES SHALL BE CAST AT THE TIME OF MANUFACTURE. HOLES FOR PIPING SHALL BE SIX INCHES LARGER THAN THE OUTSIDE DIAMETER OF THE PROPOSED PIPE. ALL SPACES BETWEEN THE MANHOLE AND THE PIPE SHALL BE COMPLETELY FILLED WITH MORTAR AND FINISHED SMOOTH. MORTAR USED FOR CONCRETE STRUCTURES SHALL CONFORM TO M C-270. MORTAR MATERIAL SHALL BE MIXED ONE PART TYPE 2 PORTLAND CEMENT TO TWO PARTS AGGREGATE BY VOLUME. PORTLAND CEMENT SHALL CONFORM TO ASTM C-144 AND AGGREGATE SHALL CONFORM TO ASTM C-144. THE CONTRACTOR SHALL FURNISH THE ENGINEER WITH SHOP DRAWINGS OF ALL PRECAST STRUCTURES FOR HIS APPROVAL PRIOR TO FABRICATION. SHOP DRAWINGS SHALL SHOW ALL DIMENSION, REINFORCING STEEL AND SPECIFICATIONS. STORM MANHOLES SHALL BE CONSTRUCTED WITH A TRAFFIC BEARING CAST-IRON SLOTTED GRATE. H. TRENCH BACKFILL SHALL BE AS SHOWN IN THE DRAINAGE DETAILS. IN ADDITION, TESTING UNDER PAVED AREAS SHALL BE AS FOLLOWS: ONE TEST LOCATION MIDWAY BETWEEN STRUCTURES AND ONE TEST LOCATION ADJACENT TO EACH STRUCTURE. ENGINEER MAY REQUEST ADDITIONAL LOCATIONS. TESTING IN EACH LOCATION SHALL BEGIN IN THE FIRST FOOT ABOVE THE CULVERT WITH TESTS EVERY TWO FEET TO WITHIN TWO FEET OF THE SUB -GRADE. DENSITY SHALL BE TO 100 PERCENT OF MAXIMUM AS DETERMINED BY AASHTO T-99. I. CONTROL STRUCTURES: SHALL BE CONSTRUCTED PER THE ABOVE SPECIFICATIONS FOR INLETS, MANHOLES, AND JUNCTION BOXES EXCEPT THAT THE STRUCTURES SHALL INCLUDE THE BLEEDERS AND WEIRS AS SHOWN ON THE DETAIL. J. RIP -RAP ENERGY DISSIPATERS: SHALL BE CONSTRUCTED PER THE DETAILS AND AS SHOWN ON THE DRAWINGS AT THE CONTROL STRUCTURES AND THE DOWNSTREAM BUBBLE -UP STRUCTURES. THE RUBBLE SHALL BE OF MATERIAL AND PLACED IN ACCORDANCE TO FDOT SECTION 530-2.3 (MATERIAL) AND FDOT SECTION 530-3.3 (CONSTRUCTION METHODS). SHOULD BROKEN CONCRETE BE USED AS THE RUBBLE, IT SHALL BE FREE FROM REINFORCING BARS OR WIRE MESH. THE CONTRACTOR SHALL USE CARE IN THE PLACEMENT OF THE STONE SO THAT IT IS NOT DROPPED ON THEW FABRIC IN SUCH A FASHION THAT TEARS THE FABRIC. THE FABRIC SHALL BE AS SPECIFIED IN FDOT SECTION 985 AND SHALL BE OF THE WOVEN DESIGN AND AS SPECIFIED FOR USE WITH RIPRAP PER TABLE 1 OF THIS SECTION. THE BEDDING STONE SHALL BE OF THE TYPE TYPICALLY USED FOR DRAINFIELD ROCK AND SHALL MEET THE REQUIREMENTS OF FDOT FOR DRAINFIELD ROCK. 7.4' 2� 3' 27.4' w 7' 7.6' 27.7' -27.7' 27.6' 27.7' 27.8' 27.8' Q w N� Q z J U U '7.5' f27.5' �27.4' �27.7' 27.3' LU LU Q ID N Z 27.3' -27.8 NE STH STREET x27.2- CIL NE 5TH STREET (F) CIL NE I 1 TH STREET (P) EDGE OF PAVEMENT 1 18" CMP 26.2' INV. ELEV. = 23.25 26 1' T x27.6' 78 CMP '25. TOE of SLOPE INV. ELEV. = 23.34 sD - FND 518" IRON ROD 0" OAK 014" TREE NO IDENTIFICATION moo- 5' x26.6' _ _ _ _ -N89° 43x25461_,E 2�- _ _ T 27. �0 50.00' ( 50.00' (P) 50.00 (P 50.00 (P) 50.00 (P) 23.8' 27. 26. 26.9' .r 26.9' 127.2' 26.9' +26 126.2' 26. 1' x25.9' u26.0' .RK f40002 IAIL & DISC 37 ILLEGIBLE 1058969.50 711817.98 MATCHLINE SHEET CD01 MATCHL_INE SEE SHEET CD02 ti w 0 w +26.0' 26.0' 26. 0' x26. 1' 26. 1' �x26. 1' FND 518 IRON ROD 024" PINE 01�„ OT, 0-,L ,. x 24. NO IDENTIFICATION 020" OAK 018" OA <4�OAK 0 0 1 014" OAKO P�24' OAKI 32' O -1 � YI I I I 012' OAK I 0" OAK I o1�' 016" P/W 014" OAK 6" OAK 012" OAK 012" OAK x x EXISTING TREE TOIY 1 I BE REMOVED, TYP. SILT FENCE, TYP. I I I 0 ,I 0, I 16" PALM x PAR11D. 0-) 3-15-37-35- 10-01100-0010 LOT 6 +26.6 -- LOT 5 /-26.0' LOT 4 LOT 3 0 LOT 2 � � LOT 1 23 9' BLOCK 1f0 BLOCK 1f0 BLOCK 1f0 BLOCK 110 BLOCK 110 �4 3' BLOCK 110 x24 1 P.B. 5, PG. 5 o I P.B. 5, PG. 5 o I P.B. 5, PG. 5 I P.B. 5, PG. 5 0 I P.B. 5, PG. 5 I P.B. 5, PG. 5 ct z olMI col I -23.5' Iv) w 0.964 CNcRE� o 072" OAK N o 0 M24" OAK +23.9' (VAC NT; 12" OAK o w 032" OAK o 0 ��I I 10 016" OAK 010" 0AI�C-16" OAf 0 � 016" OAK FN 010" OAK 20 " OAK STAR o O 026" ')A 0 0�0 FND 112 " IRON ROD & CAP BLOCK 1 1 0 STAMPED 'BSM LB 8155" P.B. 5, PG. 5 1 016" OAK 012" PINE 1 018" OAI�2" PALM �,1 022" PINE1 O + 016" OAK 076" OAK 010" OA" 14 PALM 4.7 � -1n. KOAK49-.96' - (C) 50.00' P)49 69.96C+24.349.96' (C) 4O�?" 50.00' (P) 50.00' (P) 50.00' (P) 299. ,50.00' (P 50.00 (P) 24.2' -- - 2-- -- --- PALM N89° 45' 46"E -- -- -- 20 " OA;'- O -23.6' x PALM 076" PINE +24.2' i 8" OAK_12OAK O 10 "TREEN89° 45 46E 476777'49.96' (C) 49 299.75' T 0 49.96' (C) 49.96' (C) 49.96' _(C ) 50.00(P) 50.00' (P) 50 0: lP) 0.00' (P) 50.00' (P) 50.00' (P) 12 OAK 1214 OAK_T 014" OAK 048" OAK 16" OAK FND 112 " IRON ROD & CAP I f 2 " OAK STAMPED 'BSM LB 8155" 078" OAK x I 1 x oAkl o,�K � 16„ PINL 1 I I ( -25.9' - 4. ' 24.2' - +24.2' +24.9' X P)IN<PALM � 0.965 CRES f JO„ OA (VACANT) 1 I 1 *11 " OAK010" OAK x ,5. 24.9' x OAK 022" G- 016" OAK LOT 7 LOT 8 LOT 9 LOT 10 LOT 11 LOT 12 N BLOCK 110 BLOCK 110 BLOCK 110 BLOCK 110 BLOCK 110 0 24 " OAK BLOCK 110 p P.B. 5, PG. 5 P.B. 5, PG. 5 P.B. 5, PG. 5 012" OAK P.B. 5, PG. 5 014 " Pz P.B. 5, PG. 5 O M P.B. 5, PG. 5 O14" 0, , ; :;_ M � PA EL ID: o I CDI -CDl -15-3 -35 �010-01100-0010 0 o I 16 " OAK N o l 10 I� 1 001 1 X 0OAK oo 0l 0 016" l +25.0' I -25.8' z r' 6 O16" OAK fi X"OAK 07 0 " OAK �20" OAK x OAK 74" PALMS I I 1 0 0074" OAK +23.2' 12 PALM �0 �� 2" 23.1' 4" PALM 010" OAK - - I 1 OAK �� - o 24" OAK EXISTING TREE TO BE REMOVED, O 0" PALM 14 " TREE .[)<7o't � TYP. -024" OAK 014" OAK 4' PIN 25.8' R+24.4'" OA +24 1' 016" OAK 2" PALM I I I FND 112" IRON ROD & CAP STAMPED 'BSM LB 8155" 1 xPALM I (D OAK FND 518- IRON ROD 014" PALM 34" OA �0 NO IDENTIFICATIONX., +23.0' 8" OAK 012" PALM 0121, PALM 12" TREE 14" LM +25.3' 49.97' (C) - 3.,'+49.97' (C) 49.97' (C) 12" PALM49.97' (C) 49.97' (C) 49.97' (C) 012" PALM 50.00' (P)+24.5' - - 50.00' (P)0 016" TREED - - 50.000' (P) 299, 50.00' (P) - - 50.00' (P) - - 50.00' (P)- JZ P -�O S89° 47' 50"W 78" CMP ELEV. = 2, x26.2' 26.1 ' 8' 1 25.8' 112" l ON DED-,�'fJSM L ti w Q� 5.5' 26.0 W ►I Tr I ON i !�YND� 112 �TA PED Z 25.8' 1 x26. 1' 016 PALM INV. ELEV. = 2252 26 0' x 26. 1' x25.2' x2 _ x25.4' 25.8' x26.0' EDGE OF PAVEMENT x23.4' x.,�' - NE 4TH STREET x24. 1' x24.0' -2 4 2' - 2-- --23.4' RIM ELEV. = 23.36 78" RCP S INV ELEV. - 18.46 GRAPHIC SCALE 20 0 10 20 40 80 ( IN FEET ) 1 inch = 20 ft. ,25.8' 0 0 7' SD- 25o EXISTING TREE TO BE REMOVED KEY MAP SCALE: 1.250 MATCHEINE SEE SHEET CD6 26.34' MATCHEINE SHEET CD02 9D SD SDI 5.7' 5.6' a�o 25. a�6 25.7' 25.8' 1p 6 V, W Z W Q Z N W Z w �L o Q W I � � W Z Z Q v v 6.7' �26.7' f 25.5 !!l 6' 1 24.2' 4.7' OAK00 0 o 3: � Q � 0 �� o o z z � z U CL �� 24.4' x2W' 26.8' 26.5' �24.6' 8' Z W Q I N�N LPL x275' \\\\\\\\\\\.07.-Z' m2�?3' EDGE OF PAVEMENT NE 3RD STREET 7.0 2s.s e GRAPHIC SCALE 20 0 10 20 40 80 ( IN FEET ) 1 inch = 20 ft. THIS DOCUMENT, TOGETHER WITH IS INTENDED ONLY FOR THE SPS IMPROPER RELIANCE ON THIS DOI P.E., SHALL BE WITHOUT LIABILIT 8' 6.8' LEGEND PROPOSED SILT FENCE X250 EXISTING TREE TO BE REMOVED EXISTING ASPHALT TO BE REMOVED SCALE: 1:250 o NE 5TH STREET I tLtV.= 26.12" b V 2' 943 0' ' -27.8' x2/�� x' 75, + - SAWCUT AND MATCH e EXISTING PAVEMENT 6. 1' 18" CMP 26.2' 26.2' EXISTING SIGN INV. ELEV.= 23.25' v TO BE RELOCATED ° 8, x27.6' LL 0' 18" CM ° 6.1 ' 26.0' x ° 25. 27 7� 1NV. ELEV. = 23.3 SD sa sD s0 sD �S FND 5/8" IRON RO b x26.2' 26.1' 727.4 .4' I ° °° ° ° ° v ° x26.6' v ° "89'43' 1 "Ex252699.6 ' ° ° v ° ° p x�S.Ds °° ° ° X24.9➢ ' J27. 6' ° ° - - �2 + 2� 3' 27. o 14 1�E1/ 23.8' FND 5/8- IRON ROD O 070" PINE 2 PROPER 7L f�E, TYP. NO IDENTIFICATION 020" OAK 24" PINE � � I O74' OAK ° 018" OAK N N 010" E°v I O 032" OA 074'I OAK 24" OAKS 0" OAK 1 0 2OAK 018" OAK 1 ° ° » 016" -INE O O [AWCUT AND MATCH p ° 012" OA 012" OAK EXISTING PAVEMENT PROPOSED PROPOSED �S SAWCUT AND MATCH EXISTING PAVEMENT PROPOSED BUILDING o BUILDING =I 1 BUILDING o 0 (1575 SF) Ln o O" OAK 014" AK 1 0 I o O (1931 SF) N 1 (1931 SF) a; 0 1 M 25.2' 25.8' 25.7' 26.0' I 012" AK '� 23. ' + +26. t I U. 4 �° 014" OAK +24.3' I o _ 20' 1 c I I2 �'>7P. 35.0072 OAK + 25' 48.67' ' J 072" OAK 48.67' 25.00' PERIMET �7 B7ERfvl, 76 �24" OAK 239' xI w° p • I 3'-4" 20' 27.7' I a ° 032 OAK I CONCRETE PATIO, TYP 5 016" OAK v 27.8' » o 27.8' 1 010" OAIY 16 " OAK _ _ _ _ _ 1 P O ° 016" OAK IN 1/2" l ON R D & CAP °0 1 070 OAK 20" OAK TA PED " SM LB 8755" ° I O 036" GAK I I � 27.5' 27.5' AWCUT AND MATCH XISTING PAVEMENT 1i 27.4' 7' 2 r.1 tw-1, �AWCUT AND MATCH MISTING PAVEMENT i 26.9' �x EXISTING SIGN 26.2' TO BE RELOCATE 26.1' 25.9' x26. 1' 6. 0' L. 1' SITE BENCHMARK 1140002 FND NAIL & DISC STAMPING ILLEGIBLE N. 1058969.50 E. 711817.98 ELEV. = 26.34' MATCHLINE SHEET C201 MATCHLINE SEE SHEET C202 FND 102" IRON ROD & CAP STAMPED 'BSM LB 8155" 25' v 022 PINE 48.67' v 2' PROPOSED I 1 BUILDING (1931 SF) II v 048" OAK 1 FND 112 IRON ROD & CAP ST + 6. e +25.9' PROPOSED PROPERTY LINE, I p ' TYP. 016" OAK 012" PINE " 018OA �2" PALMS 25 ° I O N v 016" OAK 76 OAK 7 010" OAKO " OAK ° +24.3' 072" OAKOAK,0 I h ° 24. ' 124. OBI " 0 OAK PROPOSED 010" OAK o BUILDING 1 I 25.5' 26.0' `3A�VCUT AND MATCH o a � (1931 SF) o EXISTING PAVEMENT 016" PINE I °1' 24.2' 1 I N 1 OAK O 10 " TREE �I O O 012" PALM 14" 0A7 TREE, TYP, 014" IAK I 1 ° CCC 7 6 OAK 012" OAK 018" I DAK SWALE I 48.67' 1 , I FND IRON ROD & CAP "SSM 014" 0 K 12" OAK 016" PIN O11 STA LB 8155" 72 0 /' 4. 018" PIN8016" PALM � v 1 15 41 _ 25' 48.67' "O O c +23.6' ° +24.9' PROPOSED 1 BUILDING (1931 SF) II ° o 1 ° FND 5/8- IRON ROD NO IDENTIFICATION +26. ' v 26.0' L 0 rn rM 024" OAK �12" OAK CD CD 0.32" 0 Q w oCn w i1) 072" OAK �64" OAK 016" OAK PROPOSED �20" OAK BUILDING o 0 O -14" OAK SF) 014" OAK 23.2 070" OAK 24" OAK 014" OAKO 076" OAK 35' +23.0 23 12 " TREE /- 14 " PALM ° ° ° ° ° °° p SS '47'50"W 29 .81' +24.2' +24.9' ° Z I 1 W 77 020" 0 K 6" OAK 010" OAK x ° ,5, 24.9 %1 OAK 022" OAK 016" OAK 0 �p M 024" OAK aw W 014" PALM 25' - , Z 16" OAK - 5.8, x26.1' 25.8' O i " OAK °O O 4j pp +2 014" OAK PROPOSED SAWCUT AND MATCH 010" OAK BUILDING EXISTING PAVEMENT (1931 SF) s 0 0 014 " OAK � 1 1 I N Lr)+�3.1 ' 7 " OAK 01 TREE v S, 24.4' ° 1 25.8" I +24.1' ° I FND 1/2" IRON ROD & CAP 1 °p 48.67' STAMPED "BSAJ LB 8755" 14" PALM 024" OAK in 074" PALM N 3 "OAK ° 072" PALM PALM n012" v 1 P p p C ° v s ° INV. = 2 2.52 p 26.0 x 26. 1' w w w w x% 25.8' x26.0' 25.7' w w w w x23.4 w w x24.1 ' w x24.0' w 18 INv. v p° x M48, j. F'� xi. ..Z' x2L4 2' � .3.'Z'�' -2.3. v° S -SD-SD SD v ° p v° 25.5' 25.8' R7 �15 78" RCP S INV. ELEV. = 18. 6' v " 5 8' S 8' x v 5.7' .8' . SAWCUT AND MATCH NE 4TH STREET EXISTING PAVEMENT _26.2,q GRAPHIC SCALE 20 0 10 20 40 ( IN FEET ) 1 inch = 20 ft. EECEND ASPHALT PAVEMENT CONCRETE WALKWAY a �74 LANDSCAPING AREA PERIMETER BERM KEY MAP SCALE: 1 :250 Project Name: Glenwood Park, LLC Owner Name: Mitch Stephens Owner Address: 17705 Middlebrook Way, Boca Raton, FL 33496 Owner Phone: 91 9-201 -991 3 Engineer Name: Steven L. Dobbs Engineering, LLC Engineer Address: 1062 Jakes Way, Okeechobee, FL 34974 Engineer Phone: 863-824-7644 Architect Name: N/A Architect Address: Architect Phone: Planner Name: N/A Planner Address: Planner Phone Block 110 Future Land Use: Multifamily Zoning: Multifamily Min Lot Width: 100.0 ft Proposed lot Width: 300.0 ft Min Lot Size: 6,250.0 sf Proposed lot size: 90169.2 sf Project Size 2.07 AC Total Duplex Units: 6 duplexes - 2 single family houses Setbacks: Coverage Impervious Area N Front Reg Provided W Side Req Provided E Side Req Provided S Rear Req Provided Residential Allowed Proposed: Proposed Bldg: 0.264 cc Allowable Impervious Area: Proposed ISR: Roofline/Bldg: Pavement/Sidewalk Total Impervious: 20 25 15 25 15 25 15 25 40% 13% 60% 51% 0.264 cc 0.450 cc 0.714 cc MATCHLINE SEE SHEET C201 MATCHLINE SHEET C202 LEGEND ASPHALT PAVEMENT CONCRETE WALKWAY A ° LANDSCAPING AREA PERIMETER BERM • ' PROPOSED , ° b Project Name: Glenwood Park, LLC 36" AK I BUILDING I ' Owner Name: Mitch Stephens PROPOSED o BUILDING � o (1575 SF) o I o o PROPOSED `� BUILDING Owner Address: 17705 Middlebrook Way, Boca Raton, FL 33496 SAWCUT AND MA 0) (1931 SF) � (1931 SF) Owner Phone: 919-201 —9913 EXISTING PAVEMENT SAWCU AND MATCH I � L' EXISTING PAVEMENT Engineer Name: Steven L. Dobbs Engineering, LLC Engineer Address: 1062 Jakes Way, Okeechobee, FL 34974 ' M o 20.00 2 ° Engineer Phone: 863-824-7644 PERIMETER BERM, TY 25' 48.67' SWALES 35.00' _ 48.67' 25' O � Architect Name: N/A 024" OAK v 036" TR E 36" OAK 036" OAK Architect Address: Architect Phone: PROPOSED SIDEWALK,F"TYP. 0 0 - 032" FREE I z 014" PINE ' ov Planner Name: N/A o z pw Planner Address: Z W 014 " OAK a Q W ° S Planner Phone Q ° ' I ' 25' W Block 121 Z � FND 1 2" IRON ROD & CAP FND 112 IRO ROD & CAP � 'BSM W Multifamily Future Land Use: Y PROPOSED PROPERTY LINE, (� W o v°° LB 8155" o—A NP• STAMPED LB 8755" 76" OAK ' OAK Zoning: Multifamily Z w 14" OAKS 0 o `r Min Lot Width: 100.0 ft M Proposed lot o PROPOSED PROPOSED W Width: 300.0 ft SAWCUT AND MATCH +" FND 7/2" l LN ROD & CAP BUILDING �° o 'B — — — — o C - BUILDING oN Z EXISTING PAVEMENT STAMPED M LB 8155" 0) (1931 SF) 0�2" °' (1931 SF) o Z Min Lot Size: 6,250.0 sf SAWCUT AND MATCH ' 0 TRH _ I I _ _ _ _ _ _ _ _ ' Q EXISTING PAVEMENT p 95832.000000 sf Proposed lot size: R5 014 " TREE 016" OAK + FND 1/2" IRD ROD & CAP Project Size 2.20 ac 0 ° 25' 48.67' 012 TREE 0 STAMPED "8 M LB 8155 48.67' v 6 duplexes — 2 16" OAK 8 20 CONCRETE Total Duplex single family P 12" TREE I x PATIO, TYP. O 12 OAK 76" OAK d P Units: houses PROPOSED SIDEWALK, TYP. o , I TREE, TYP. " 4 PALM 20" PINE �0 I Setbacks: � N Front Req 2" AL Provided v a W Side Req I PROPOSED SIDEWALK, TYPi Provided I D E Side Req Provided D 25' 8" OA 25' o Rear Req F35.00;� 024" OAK Provided SAWCUT ANC EXISTING PA GRAPHIC SCALE 20 0 10 20 40 80 ( IN FEET ) 1 inch = 20 ft. Coverage Residential Allowed Proposed: Proposed Bldg: 0.34 ac Pool & Deck: 0.00 ac Total Proposed: 0.34 ac Impervious Area Allowable Impervious Area: Proposed ISR: Roofline/Bldg: Pavement/Sidewalk: Total Impervious: 20 25 15 25 15 25 15 25 0.34 ac 0.46 ac 0.80 ac 40% 15% 60% 36% SCALE: 1 :250 PROPOSE SAWCUT EXIST. 40 LF 1: PROPOSE PROPOSI INV. EL.= SAWCUT EXIST. 40 LF 1: PROPOSI INV. EL.= PROPOSI INV. EL.= SAWCUT EXIST. 40 LF 1: PROPOSI INV. EL.= 7 LF 1 INV. EL.= Cf NI M MATCHLINE SHEET C301 MATCHLINE SEE SHEET C302 IP .50 AES 4.20 MATCH ENT AES 4.40 M ES 4.60 MATCH ENT MP AES C80 AES 5.00 MATCH I ENT MP AES 4.80 MP 3.65 LEGEND X 31.20 PROPOSED ELEVATION X 32.64' EXISTING ELEVATION FLOW OF DIRECTION ❑o PROPOSED DRAIN INLET cw PROPOSED MSE PROPOSED DRAIN PIPE PERIMETER BERM SCALE: 1:250 a i t w � w z O z J 5' 5' J z D.E. D.E. z w w LL 10' SWALE � Q Q w w MATCH MATCH EXISTING EXISTING GRADE 3:7 3.1 GRADE ----- BOT. EL. AS REQUIRED TYPICAL SECTION A -A KI /2 - - T C I AIC\All IAICC` ROADWAY ASPHALT PAVED ± 19' MATCH EXISTING GRADE a AS hKHUL REQUIRED PERIMETER BERM TYPICAL SECTION B-B 09/22 - - N.T.S. INEWLINES MATCHEINE SEE SHEET C301 MATCHEINE SHEET C302 -SD 8D 8D 9D 75�7' I 5.6' OI25.7'mo pH�] 7 LF 12" CMP INV. EL.= 24.72 PROPOSED MES INV. EL.= 24.90 SAWCUT AND MATC EXIST. PAVEMEN 40 LF 12" CMP PROPOSED MES INV. EL.= 25.00 PROPOSED MES INV. EL.= 25.70 SAWCUT AND MATC EXIST. PAVEMEN 40 LF 12" CMP PROPOSED MES INV. EL.= 25.80 PROPOSED MES INV. EL.= 26.00 SAWCUT AND EXIST. PA 40 LF 12" CMP SiTREFT 7 LF 12" CMP 40 LF 12" CMP INV. EL.= 24.68--\" -mr, RIM F1 FV = 2.5 .57' _9 25.8SD 9D SD -SD -SD -SD -SD -SD - SD SD_SD SD SD r24.70 o r X 24.60 25.7' If O NO D r L.= 2 4. +.3' ° • v L ° ° ° ° 26.10 ° ° ° ° °➢ , X 26.50� v t o o ° v V v � PERIMETER BERM 1 TOP EL.=27.00 ° 1 24.90 27.00 27.00 I +25.1 ' Y.77 AA. I 25 6' 0 1 36" OAK +25.5'I +25.3' F.F.E. =28.40 F.F.E.=28.40 I I 27.00 27.00 25.00 ° �- A 024" OAK ° 1 + 5. ° 27.25. I Ld v 014" OAK BOT_ELEV.=245h _ TOP ELEV.=:-?26.00 • Q v SWALE 0.218 AC +25.2' SAWCUT AND MATCH EXIST. LF 12' PAVEMENT EL.=-PROPOSED MES RIM ELEV = 23.68' INV. EL.= 24.30 78" RCP N INV. ELEV. = 18.48'5 tINV RCP W INV. ELEV = 58'5' RCP E INV. ELEV = 77.SD SD SD SD SD SD SD SD SD SD SD SD SD SD SDSD G24.30 - X 24.20 - �Z�_�� - - 23.6' 23.80 x24.5' ' - OVHD 0 +24.9' x24.4' 24,° 0 N1D ADS PIPE° +2 .0x2 2' 26.50 a ' ° x24.9 ° i0X • 26.10' E PROOLSTR2) GRA0NE..33 42" OAK 01 27.00 +24.7 ° +25. ' 24 d 27.00 27.00 v rO CD l0 1 r 4 IQo N N 24.1,LLI F.F.E.=28.40 ql Ld J J Ld Ld I 24. F-- ILL 1 24.4' ,x2 2 m I0 1 .5' 27.00 27.00 2 O 036"TRE OAK 036" OAK 1 014 " PINE o +25.5' ° X 27.00 4. B CMP 23.85 5.5' SD SD SD SD- 25.6' 25.6 25.9' OVHO 0 i LF 12' CMP INV. L.= 23 85 w 1 I 1 2 .2' Q .50 4.7' s 25.70 A 25.60 N 27.O " OAK 27.00 Ld 1 z I I 14" OAKS 1 1 I 2 .1' 1 0 0 +25.1 ' N - a' F.F.E.=28.40 +25.1' _ _ 125.0' F.F.E.=28.40 -2 1' .�I 012 " TREE 1 I 1 1 I 014 " TREE I 1 ,• '1 -24.5' 4 2 27.50 27.50 012 " TREE016 " OAK 27.00 27.002 25.80 I 25. PERIMETER BERM 016" OAK 26.7' 26. 26 5' TOP EL.=27.00 x 6.7 72" TREE 016" OAK 12" OAK > 1 x26.8' 1 I I +26.0' 14" PALM 20" PINES 1 � I s 75 +25.9' _+2.5.7' - - - - +25.0' Z� 27.00 26 6' 111 2.627. x -- --�-- -- x26.4' ' v x27.1' a B I B I I 1 1 I I TOP PERIMETER EL.278M 00 +25.0' x 5' v 4 8" OAK . 9' 24" OAK ° 26.00 0 ° 25.00 28.00 1 28.00 27.00 27.00 ° 1 +26.9 I ° z • I 1 7 v 1 26.9' I 1 1' ' 9' x26.9' I I q F.F.E. = 28.40 26.6' +26.6' +25 F.F.E. = 28.40 25.2' " oAK 2 2' o 1 I F.F.E.=28.40 I 1 q l 1 074 A/ M I 1 pp x26.7' 018" PALM Q o ° 28.00 28.00 27.00 127.00 26.20 1 x25.8' 28.00 X 28.00 ` ' 25. po 1 I I 12 I 1 I 032" OAK 1 27.2' 7.5' 2 •1 ' � ° 4.8' 25.6' PROPOSED MES INV. I x26 6' PROPOSED MES 25 0 • PROPOSED x25.7' + EL.= 25.70 �9 -\ INV. EL.= 25.50 INV. �- EL.- 6.20 r27.' 26 +25.9' -25.6' x26.4' x25.5 ° 28.00- - C ° x ° 27.00• -97 ' v o ° X 27.55 , xr 28.00 ° P s XQ7.50 ° ° ° r-L ° x ° v ° 6j 7 ' oD X 27.10 - - - - 25.6'24.9 • r 27.2' DAD ° � x25 OPOSED MES INV. = 24.90 �- S WCUT AND MATCH EXIST. PAVEMENT 25.9' 26.3' 26.1 40 LF 12" CMP OPOSED MES INV. 25.00 LLJ z Ld Q 0 LLI Z 00 0 0 --PROPOSED MES INV. o E .= 25.60 0 0 z SAWCUT AND MATCH EXIST. PAVEMENT �' 26.8' 4�26.5 LF 12" CMP 5' 26.8' ROPOSED MES INV. 25.80 26.6 OPOSED MES INV. = 25.00 WCUT AND MATCH IST. PAVEMENT "40 LF 12" CMP .5' P OPOSED MES INV. E .= 25.20 7 LF 12" CMP INV. 6 26.9' 25.825.30 / DAD . �x26.8 26.6' 26.00 30 " CMP 7 x NV ELEV = 25 44' 0 NE 3RD STREET 40 LF 12" CMP SAWCUT AND MATCH EXIST. cRQ•1'�7"w 7rQ RA' PAVEMENT GRAPHIC SCALE 20 0 10 20 40 80 ( IN FEET ) 1 inch = 20 ft. g 6.7' 270 26•9 7 LF 12" CMP w INV. EL.= 25.40 b I LEGEND x 31.20 PROPOSED ELEVATION x 32.64' EXISTING ELEVATION FLOW OF DIRECTION ❑� PROPOSED DRAIN INLET Cw PROPOSED MSE PROPOSED DRAIN PIPE PERIMETER BERM SCALE: 1:250 w z J z �� 0 J �� w z J z D.E. D.E. w w :5 :5 WALE Q10' Q w v MATCH MATCH EXISTING EXISTING GRADE 3_ 7 3.1 GRADE _---- MqX MPX ___-- BOT. EL. AS REQURED TYPICAL SECTION A -A \1 T Q -#- C SIC\A/I MCC ROADWAY ASPHALT PAVED ± 19' MATCH EXISTING GRADE TYPICAL SECTION B-B >R AS vKHUt REQURED PERIMETER BERM 09/22 N.T.S. NE 5TH STREET 04 N C4 MATCHEINE SEE SHEET C402 v e v A7. 0 C I A�_ .5.60 a0 27.5 c I00 v (� o ;I II ■ 78' 27.4 127 6' 2� 3' 274' 45' 27.7' -27.7' 27.7' 27.8' 21d. W Q N Lu 275' 275' 213 L'F SDR 26 0.4% LOPE �274' 1277' 8" 1 INV. 273' 26.9' J272' 8" WY INV. EL.= p ■27.6' 26.20 25.30- 24.30- 17� p o NV. tl/ =233b`X.27.60•,p ° w �27.55. w • w ° X L. w p ° w p 26.589 v - - 27.50. _ L - 2: 27.5 7.5A 7. 4"x 8�� 135 LF SDR 26 0 0.4% SLOPE 024" PINE ECCENTRIC O 010" INE F020" OAK REDUCER 14" OAK CO #3 v 018" OAK 8" 45' ELBOW INV. EL.=24.10 OI ' I E �0 032" 0- 014' OAK CO #2 24" OAK 01 �" OA O" OAK INV. EL.=24.37 018" OAK ° 26.30 v 27.50 27.50 4" SERVICE, TYP. 27.00 27. 28.00 28.00 O 16 " INE 014" 0 CO #1 072" OAK 012" OAK ° v INV. EL.=24.64 Bo I I - 4"x 8" 8" 45' BOW ECCENTRIC O" OAK 014" OAK ' REDUCER 4"x 8" ECCENTRIC � � � CO INV. E11L.=24.78 � 26.0' 012" OAK REDUCER + +26.6' I ° lw + G3i 8" LONG SWEEP 90' ELBOW 26.2' 26.0' 26. 1 26.0' 25.9' X26.1 ' +LJ.J 28.00 CO #12 INV. EL.=24.58 022" PINE 28.00 8" 45' ELBOW 4"x 8" ECCENTRIC REDUCER CO #13 INV. EL.=24.38 28.00 U48" OAK 014" OAK Q 012" OAK CO #4 J 24 " OAK +23.9' I 12 OAK J INV. EL.=23.80 I 032" OAK I 016" OAK 010" OAK,-16 " OAK �76" OAK 010 OAK 20" OAK 036" OAK CO #5 I INV. EL.=23.60 . 076" OAK 012" PINE N 018" OAK2" PALM "I07 I 6 " OAK 27.00 16" OAK 1 OAK 010" OAI�O 14 " OAK __l_ +24.3' 072" OAK 0 I O \- 0" OAK 8" 45' BOW � �. � - - - 070" OAK 076 PINE I + 24.2' 4"x 8" M12" OAK 010 TREE ECCENTRIC REDUCER O 012" PALM �14" OA 014" bA K I 27.00 076" OAK 072" OAK 018" IOAK CO #6 J 014" OAK i 12" OAK 016" PlN INV. EL.=23.40 I 018" PINLOI6" PALM 12" OAK 032" -- -- -- "I»777=- -CO #141NV. O/ 012" OAK EL.=24.18 I 014" OAK I 0 27.50 v , 8 45' ELBOW „ 016" OAK �20" OAK 4"x 8" O � 14 " OAK +23.2' REDUCER ECCENTRIC 0074" OAK -CO #15 010" OAK INV. EL.=23.98 24" OAK 024" OAK 014" OAKO CO #18 INV. EL.=23.28 i 0 27.50 CO # 17 > 27.00 CO #16 INV. EL.=23.59 f INV. EL.=23.89 016 8" 45' ELBOW - S S 260 LF SOR 26 ® 0.4% SLOF E S +23.0' 8 WYE �72" TRLL -74" PALM INV. EL.=23.283 1•��E 27.00 ° ° x • X26.83, p • ° ° �' v S8)47'50"W 2G v v w w w X 24.10 RIM ELEV. = 25.57' w w EXISTING 6" WATER MAIN w +24.2' +24.9' 020" 6" OAK 010" OAK 0 K %7 " OAK 022" OAK 016" OAK CO #7 INV. EL.=23.20 024" OAK I 014" PALM 27.0 �16" OAK 0 0 "OAK 014" OAK 010" OAK 8" 45' ELBOW I 4"x 8" ECCENTRIC 014 " OAK REDUCER +�3.1 ' 12 " OAK CO #8 INV. EL.=23.00 - 8" INV. WYE 07 TREE EL.=23.00 CO #9 W INV. EL.=22.88 -, 7x 00 I CO #19 +24.1' 27.0 + INV. EL.=23.05 8" 45' ELBOW Q 7 4 " PALM P s ' v ' #26 CN 0 �v v� LJ 27.00 0 o cv 11 11 36" OAK CO #10 8" 45' ELBOW INV. EL. �2 5P LM 012' ALM P.41 , All C _ INV. = 2 .52 W. EL.=23.00 INV. EL.=22.85 w x2 w w -24.1' w X24.0' w ■2�. Z W •. :23.30J ~`2� 22.90�-- _2 fN 23. 6' 18 RCP S INV. ELEV. = 18. 6' O. CO #39to LC*4INV. EL.=23.18 IJ M RIM ELEV. = 23.68' (Ij 18" RCP N INV ELEV. = 78.48' 3 it '-A. 7' 11 18" CMP 26.2' INV. ELEV. = 23.25' 6.1 ' 26.0, 25. SD 3D 8D 3D Si .3.30 -26.2' 26.1 5' 25.8' •' s 8" LONG SWE P 90' 3.8' ELBOW 24.20 25.8' 25.7' J. WYE I V. EL.= 3.80 24.60 271 LF S R 26 4' 0.4% SLOPE 25.5' 26.0' 25.8' " WYE I V. EL.= 3.40 24.80 W Z .25.00 ; 24.9 M W ;25.00 Z ■26. 1 ' 25.8' 8" WE r INV. L.=23.0 24.80 8" LONG SWEEP 90' ELBO LEGEND PROPOSED SEWEREINE SQ PROPOSED SEWER MANHOLE PROPOSED SANITARY SEWER CEEANOUT PROPOSED DRAIN PIPE PROPOSED WATERLINE PROPOSED DRAIN INLET PROPOSED FIRE HYDRANT PROPOSED WATER METER SCALE: 1:250 MATCHLINE SEE SHEET C401 -3D SD 3D 3D� 5.7' 5.6' OHAO OHAO . OINp 25.7' 0 25.8' , 25.9' 8" INV. EL.=: EXISTING 6" WATER MAIN 8" VINE INV. EL.=2 7' #26.7' 8" v 1 ' RIM ELEV. = 25.57' 5' RCP E INV. ELEV. = 18.62' -SD � 3D SD SD an an an e" .. NE 4TH STREET X 24.70 5.7' s OINO yHp wI + O D D O-L 2 .3' +25.1' •ac'26.10 . ° ° ° .P� , ° ° X 26.50� 0 27.00' ° 8" LONG SWEEP 90' 8" WYE ELBOW CO #36 INV. EL.=23.77 CO #35 INV. EL.=24.08 S INV. EL.=24.38 S S S 222 LF SDR 26 0 0 4% SLOPE 27.00 ; 27.00 27,00 4"x 8" ECCENTRIC REDUCER - 7.2' k27.5' j2�.1 ;27.3' 27.2' DN'0 / MATCHLINE SEE SHEET C403 g RIM ELEV = 23.68' CO #38 78" RCP N INV. ELEV. = 18.48' INV. EL.=23.31 5 RCP W INV. ELEV. = 58' 5' RCP E INV. ELEV. = 17. • ° SD SD SD SD SD SD SD SD SD SD SD SD X 24.20 x24.5' ° +24.9' x24.4' 24 T'° 0 ° + ° X 26.50 .. ° B ° ° x24.9 ° ° 7 v CA I 3 '--A. 7' CO #29 INV. EL.=23.51 4v° S S v° I CO #38 INV. /24.7' CO #287f , + EL.=23.51 INV. EL.=23.77 27.00 27.0 8" 45' ELBOW 8" 45' ELBOW_j 11 ° o ' NOV.#EL.=24.44 36" OAK CC #37 �I 56' -25.5'I IN . EL.=23.77 +25.3' S.0' 24.8 4"x 8" ECCENTRIC 4"x 8" REDUCER +2 ' ECCENTRIC REDUCER 3 I CO #27 INV. EL.=24.00 4 ° �(n I W °� o 8" 45' ELBOW + ' 4t.�x ° ' I 5' 2.: 27.00 27.00 27.00 27.00 I 25.00 ° N o ° O �36" 024" OAK "E OAK 036" OAK 036 TR v CO #33 INV. EL.=24.65 � 0 J2 FREE +25.3' 014" PINE ' 5.A7.25___T25.,IIo" 6LQ -O +25.2 +25.5' -- ° X27.00 +25.2' 4. I 074" OAK � ' I CO #26 INV. a 225 LF SDR 26 0 EL.=24.23 P o N 0.4% SLOPE 5' -SD 8D 8D- 6' 25.6 25.9' OVHD OVH 80 L SDR 26 % SL PE LONG' SWEEPI 90' AUTIA11 2 / INV. EL =24.00 25.9' 26.3' Z5.00 Lu W Q M W Z 24.2' 0 L 4.7' s 25.70 �, 2 27.00, 27.00 16" OAK K o CO #32 8" 45' ELBOW ' INV. EL.=24.86 I 2 1, 14 " OAK N' +25.6 - -- I-- -- -- -- - -- - 3 +25.1' 4"x 8" ECCENTRIC 8 • +25.1 ' _ _ +25.0' REDUCER - - 2 . 1 O " 7 2 TRH ' 4"x8„ -- - -- -- -- -I -- - -COS- ' ECCENTRIC EL.=24.44 77, REDUCER I 014 " TREE W + 2 016" OAK 25.80 27.50 27.50 072" TREE 27.00 N 27.002 I s 016" OAK x 6 7 ' 12" TREE I 076" OAK 12" OAK- r x26.8 NO # V.EL1=25.00 I 74" PALM +26.0' 0 20" PINES ' 627; 5 - - - -� - - - - c, x26.4' +25.9 - - -+�7' - - - - 25.0' r 27.00 x v x27. 1' a P CO #25 INV. +2 V EL.=24.65 v 8" OAK 26.00 ° 024" OAK v 28. 0 28.00 I 27.00 ' 27.00 I -26.9' 1 N o +26.9' W 1x26.9' 9' 8" 45' ELBOW I CO #30 I INV. EL.=25.28 4"x 8" ECCENTRI q 252 "x 8" 1 26.7' 26.6' +26.6' -25 ' REDUCE +25.2' CCENTRIC ; REDUCER I BO 23 0/4" ALM O NOV.#EL.=2 .86 ° x26.7' 78 PALM 77 3: CO #20 INV. EL.=25.5 26. 1' 293 LF SDR 26 0.4% SLOPE 8" WYE INV. EL1=24.44 26.7' T26.8' �26.5 1 J26.5' ;26.8' �26.6 " OAK 8" WYE INV. EL =24.86 o ° 28.00 28.00 " 27.00 27.00J 7' 26.20 ° 1 x25.8' 28.00 X 28.00 4 SERVICE, TYP. 25.: I CO #22 $ I o � a INV. EL.=24.96 � ' 4"x 8" ECCENTRIC ^^I^, 032" OAK \ 95 In 4.8' v x25.6' x25.7' + 2 ° 2S>. +25.9' +25.6' 25.5 X 27.55 x ° v � s v o X27.10 p�Mv w w lw �26.3 D � �26.00� 2; 4" SEWER SERVICE, TYP. REDUCER --� 3 Ix26.4' 28.00 25.6' 8" 45' ELBOW NE 3RD STREET � S � 8.00 5 X 27.50 p ° �• v GRAPHIC SCALE 20 0 10 20 40 80 ■ 5.c� q x° h "2 ' �0 ° ' 47 26.6' 26.9' 26.8 9 8" LONG SWEEP Xw25.40 2tf4BOW 30" CMP x 5' .9' 6.7' INV. ELEV. = 25.44' 2 27.0 26.9 b LEGEND PROPOSED SEWERLINE SQ PROPOSED SEWER MANHOLE �- PROPOSED SANITARY SEWER CEEANOUT PROPOSED DRAIN PIPE PROPOSED WATERLINE PROPOSED DRAIN INLET PROPOSED FIRE HYDRANT PROPOSED WATER METER SCALE: 1:250 ( IN FEET ) 1 inch = 20 ft. 0 NE 5TH STREET INSTALL 16"x 8" TAPPING SLEEVE AND VALVE INV. EL.= 24.00 (APPROX.) 7.4' 27.4' J27.6' 2g 3' 27.4' EXISTING 16" WM 10Ol_ MATCHLINE SEE SHEET C402 v X27.6' 24.30 ➢ ➢26.20 25.30 Nv. ELEV = 23.3 f7� b ➢ X,27.60 ° .27.55. W ° • W v°yy ° w • , ° N ° ➢ 26.58� w _° ° 2: ➢ 27.50 __� 8, - - 11 m �!r PROPOSED 8" m m 27.5 m m 7' ➢° WATERMAIN S S 024" PINE I 014" OAK 010" PINE ➢ 020" OAK F018" OAK � 07 E°, O o 074' OAK O32" OA ' � 24" OAKS 0" OAK 018" OAK J2�1 ")1?"OAKV63I 27.50 27.5028.00 28.00 016" INE 27.00 012" OAK O74" 0 O12" OAK 0" OAK 014" OAK' ' 00 27.7' X27.7' 27 6' 27.7' ?7.8' W, D W Q 0 N Z '7.5' 27.5' i� 00 27.4' 27.3' �127.7' m 0 0 o / / 7.3' 9' J27.2' 126.3: 26.2' 26.0' 26.1 ' 26.0' 25.9' ■26.1 ' 1 " POLY I - 26.6' 1 " POLY v'Lo- 28.00 ➢ I () 1 27.50 I 1 II I 1 " POLY 28.00 0 22 " PINE 28.00 28.00 U48" OAK .50 f26.0' I 072" OAK 1" POLY + I W ➢ 4 014" OAK +24.3' • +23.5' 27.00 27.00 Q 012" OAK ' 24 " OAK +23.9' 12 OAK 1 I N � O32" OAK 1 016" OI K I 010" OA�16" OAK 0 -26.20 1' 18" CMP 2� -, INV. ELEV. = 2, 1 6.' '25. ' 016" OAK 070 OAK 20" OAK O° 036" OAK I INSTALL FIRE HYDRANT ASSEMBLY 8" TEE 8" GATE VALVE ADD 2" WL TO SERVE HOUSES AS SHOWN 8"x 1" SADDLE w/ 1" CORP STOP 25.2' 25.8' 25.7' Lu W 40 Q M W Z I 076" OAK 012" PINE v I 078" OAK2" PALM N 1 24.E 076" OAK 27.00 27.00 16" OAK I " OAK 010" OAt +24.3' OAK 012" OAK�0 4. ° 4. � OBI � 0 OAK 010" OAK I I o 016" PINE I +24.2' 1 12 " OAK 010 " TREE I 00 a 0 1 " POLY W 012" PALM 14" OA 014" LAK I ' 27.00 ° 27.00 016" OAK 012" OAK 018" IOAK I WI • 1 24.1 IE 074" OAK 12" OAK 016" PIN +24.2' r12" OAK 078" PlNLO76" PALM O 032" c -(D77""777-- +23.6' 016" OAK - 24.9' 1-20" OAK 0 0- 14 " OAK 074" OAK 010" OAK 24" OAK 024" OAK 014" OAKO 27.50 1 27.( 012" OAK 074" OAK • pO _ +23.2' LJ.YV 16 OAK S S S S > J +23.0' CL 23 12" TREE �74" PALM 3 6 TREE 27.00 • X 26.66 ° • a • X 26.83 , ° • °� s " w w- ° 24.70 d v o EXISTING 6" WM 6.1' v w w w w w X 24.10 2 RIM ELEV. = 25.57' 012" 0 K 1 4. +24.2' 24.9 ' I 1 v -- -- -- -- *26.20 25.( I ' ° 020" 6" OAK 010" OAK 5,f4.9 P O K �I,2 OAK 022" OAK 016" OAK 024" OAK v 014" PALM ° ° 27.0 25A 27.00 7 6 " OAK 0 01 OAK .8 074" OAK 070" OAK I I �IE 014" OAK I I U 72" OAK 00 01 TREE 1 " POLY W r_.,, Iv 27.00 1 +24.1 ' 27.0 - 27 I 1 ➢ 14" PALM j;;p5:r v36" OAK 101 (� ' 012" PALM 012" PALM ° 27 P 7.00 • s ° ➢ s v p *2 26.33. • C V. INV. = 2 .52 w x2 w w ■24.1 ' w X24.0' w ■2y�. s 23.30? ~`2 22.90"�- _2 23. 6' o EXISTING 6" WM 18" RCP S INV. ELEV. = 18. 6' ° � s N89'47'50"E 369.84' NE 4TH STREET (BASIS OF BEARINGS) GRAPHIC SCALE 20 0 10 20 40 RIM ELEV. = 23.68' 18" RCP N INV. ELEV. = 18.48' 80 h 5'.0 25.8' u-i �00 8% 1 " SADDLE w/ 1 " CORP STOP w i� 0 0 N , A25.8' -26. 1'�25.8' 8"x 1" SADDLE w/ 1" CORP STOP 26.0' 126.1' 25.8' "26.0' 25.7' 69 SD 8D �C 22.50-8 25.5' 25.8' 3 x 5.8' S.8' 5.7' INSTALL FIRE HYDRANT ASSEMBLY 8" TEE 8" GATE VALVE .7' LEGEND w EXISTING WATERLINE PROPOSED WATERLINE PROPOSED FIRE HYDRANT PROPOSED WATER METER ❑ G PROPOSED SEWERLINE PROPOSED DRAIN PIPE BLOCK 121 p PROPOSED DRAIN INLET KEY MAP �S PROPOSED SEWER MANHOLE SCALE: 1:250 PROPOSED SANITARY SEWER CLEANOUT NOTE: SEE INSET "A" ON SHEET C401 ( IN FEET ) 1 inch = 20 ft. MATCHLINE SEE SHEET C401 -X NE 4TH STREET 3 CONNECT TO THE EXISTING .7' WATER MAIN ON THE OTHER SIDE OF THE 5.5' STREET r LEGEND OH^I OINO° I' 2 .3'° 0 ➢ + 1' N � t iiv. t�tv. -SD SD 8D SD SD ° 1 2 2' BLOCK 11u❑0 D D sD SD SD SD SD SD SD SD SD. -SD -SD --SD SD SD SD D 8D SD SDW EXISTING WATERLINE 5.7' 24.50"Mcil;.24.30 X 24.20� .- 25.6 X24.70 23.6'23.80 25.9' ONO 5.6' 25.7° +24.9' X24.5' ■24.4' 24 OHD _ PROPOSED WATERLINE El Ll - O D 0 + 25. 1' 2 25.7' ` -24.1 PROPOSED FIRE HYDRANT ,26.10 0x2s.5ox2s.5o T °° 6 .. 00 25.8' 25.9' PROPOSED WATER METER2 LJ ° 1 S S S S S S 1° PROPOSED SEWERLINE ➢° 1 I +24.7' 1 V24� 27.00 2700 24so PROPOSED DRAIN PIPE BLOCK 121 2-, 27.00 27.0o z7.00p PROPOSED DRAIN INLET E ISTING 16" WM U) ° ➢ KEY MAP 36" OAK 1 +25.5' ��+24.8' PROPOSED SEWER MANHOLES�A�E: 250 +25.3' ,+24.12"x 1" SADDLE w/ 1"PROPOSED SANITARY ' I CORP sroP 9�- SEWER CLEANOUT W 0 W ZD V) z w Q 0 z N W ' �26.7' INSTALL 16" �782 TA� PIN AND INV. L.= 24.00 (AF _0 27.3' 27.2' DwD DAD MATCHLINE SEE SHEET C403 PROPOSED 8" WATER MAIN MAIN GRAPHIC SCALE 20 0 10 20 40 80 ?5. 9, 26.3' 26.1 ' 2" WM W z W > Q 0 Cl) W z 00 0 O 0 I0 0 Z ?6.7' 26.8' 26.5 2"x 1" SADDLE w/ 1" CORP STOP 26.5' 26.8' 26.6' 2"x 1 " SADDLE w/ 1 " CORP STOP 4.8, 26.5' 47° 26.6' ]26.9' 26.8 4.9' 26., 40 26.6' 30 " CMP 7, INV. ELEV.= 25.44' NOTE: * SEE INSET "A" ON SHEET C402 ( IN FEET ) 1 inch = 20 ft. DIMENSIONS & QUANTITIES RISE R SPAN S X A B C E F G M N GRATE SIZES CONCRETE (CU. YDS.) SODDING (SO. YDS.) SINGLE PIPE DOUBLE PIPE TRIPLE PIPE QUAD. PIPE STANDARD WEIGHT PIPE EXTRA STRONG PIPE SINGLE PIPE DOUBLE PIPE TRIPLE PIPE QUAD. PIPE SINGLE PIPE DOUBLE PIPE TRIPLE PIPE QUAD. PIPE 12" 18" 2'-10' 2.36' 3.06' 5.42' 3.03' 5' 1.50' 4.92' 7.75' 10.58' 13.42' 1.21' 0.68 1.04 1.41 1.77 8 9 11 12 14" 23" 3'-4" 2.44' 3.75' 6.19' 3.70' 6' 1.90' 5.38' 8.71' 12.04' 15.38' 1. 23' 0.76 1.19 1.63 2.05 9 10 12 13 19" 30" 4'-0" 2.62' 5.47' 8.09' 5.36' 8' 2,37' 6.04' 10.04' 14.04' 18.04' 1.27' 2.5" 3" 0.95 1.52 2.09 2.65 10 12 13 15 24" 38" 5'-0" 2.79' 7.18'0 9.97' 7.03' 10' 2,85' 6.79' 11.79' 16.79' 21.79' 1.31' 2.5" 3" 1.18 1.95 2.74 3.53 11 13 15 18 29" 45" 5-11' 3.05' 8.90' 11.95' 8.70' 12' 3.19' 7,50' 13.42 19.33 25.25 1.38' 2.5" 3.5" 1.41 2.42 3.44 4.45 12 15 18 20 34 53" 7'-0" 3.22' 10.62' 13.84' 10.36' 13' 3.57' 8.25 15.25 22.25 29.25 1.42' 3" 3.5" 1.63 2.92 4.22 5.52 13 17 20 23 38 60 ' 7'-10' 3.39' 1 1 .99' 15.38' 1 1 .70' 15' 3.95' 8.92 1 6.75 24.58 32.42 1 .46' 3" 4" 1.83 3.36 4.89 6.41 14 18 21 25 43 68 8'-11' 3.56' 13.71' 17.27' 13.36' 17' 4.28' 9. 77 18.58 27.50 36.42 1.50' 3" 4" 2.09 3.95 5.80 7.65 16 20 23 27 48" 76" 9'-11' 3.73' 15.43' 19.16' 15.03 19' 4.59' 10.42' 20.33 30.25 40.17' 1.54' SPECIAL SPECIAL 2.37 4.54 6.73 8.92 17 21 26 30 53" 83" 10'-8' 3.91 17.15' 21.06'1 16.70' 20' 4.77' 11.08' 21.75 32.42 43.08 1.58' SPECIAL SPECIAL 2.61 5.09 7.56 10.03 18 23 27 32 58" 91 11'-8' 4.08' 18.87' 22.95' 18.36' 22' 5,01' 11.83' 23.50 35.17 46.83 1.63' SPECIAL SPECIAL 2.91 5.77 8.64 1.50 19 24 29 35 SO BEVELED OR CONSTRUCTION SLOP VARIES 2, ROUND CORNERS N JOINT PERMITTED PgVEMENTN T U SOD MOD FCA / NgLo 17 GRATE DETAILS,q S, 0 0 0 0 0 0C T 2' GRq TES � 14 „ SPACED L�j C.TO :5 cf) LL 0 c om w CONCRETE CONNECTOR CONSTRUCTION JOINT PERMITTED �Q PIPE i DITCH GRADE SADDLE I I z Ln 2' NOT LESSIn o 0 0 o NO PIPE JOINT PERMITTEDLo FASTENER PAID FOR AS UNLESS APPROVED BY THE EN INEER PIPE CULVERT E 32' SOD SOD F (PIPE TO BE IN ELIDED UNDER UNIT PRICE FOR MITERED END SECTION) CONCRETE SLAB, 3" THICK, REINFORCED N WITH WWF 6X6-W1.4XW1.4 *SLOPE: TO MAJOR AXIS FOR PIPES 24" X 38" AND SMALLER. 2:1 FOR PIPES 29"!45" AND LARGER. 1n I TOP VIEW -SINGLE PIPE SECTION SIDE DRAIN MITERED END SECTION 2'-4" 2 1 „ 11" 2„ � 2„ O O O O O O _ O O PIPE 00 O 0 0 O O O O O O O O O cf) �O O n_ N � 2'-4" w r �w L 00 1" �0ry L` PLAN 71 00 APPROX. WEIGHT 235 LBS. o 1,- 2'-4" z z 3'-4" 3" x 5T ry L o w zO 2'-0" w 1 GRATE co PIPE x w 2" CL. Ud QLni� n @� > 0 Cw cn N 18 Q w m BOLTS EYE cwn INDEX SEE t L 201 c #4 BARS @ 12" CTRS. 12"0 WEEPHOLE STRAIGHT BARS 2"X 4" SECTION W/ROCK/FILTER RETICULINE BARS 1 1"X16" FABRIC BANDS 2"X "' RECOMMENDED MAXIMUM PIPE SIZE: APPROX. WEIGHT 104 LBS. 2'-0" WALL-18" PIPE NOTES: 1) STEEL GRATES ARE REQUIRED ON INLETS 2) ALL INLETS WILL BE CAST TO PROVIDE A 18" WITH TRAVERSABLE SLOTS AND ON INLETS SUMP BELOW LOWEST CULVERT INVERT WHERE BICYCLE TRAFFIC IS ANTICIPATED. PRE -CAST TYPE 'E' CATCH BASIN 0DR nITc nIF ��nn IN 1 1/2" TYPE SP 9.5 ASPHALTIC CONCRETE 12" STABILIZED SUB -GRADE FBV OF 75 PSI COMPACTED TO 98% MAX. DENSITY PER AASHTO T-180 METHOD. SUB -GRADE SHALL MEET LBR 40 PAVEMENT SECTION 8" LIMESTONE OR COQUINA BASE COMPACTED TO 98% MAX. DENSITY PER AASHTO T-180 METHOD. BASE SHALL MEET LBR 100 09/22 FL CD 6 N.T.S. NEWLINES ISOMETRIC VIEW JOINTS WOVEN OR NON -WOVEN FILTER 12 12 FABRIC TYPE D-3 (SEE INDEX MIN. MIN. 199) SECURING DEVICE ELLIPTICAL PIPE JOINTS ROUND PIPE PIPE SECTIONS COST OF FILTER FABRIC JACKET TO BE INCLUDED IN COST OF PIPE CULVERTS FOR ALL PIPE TYPES FILTER FABRIC JACKET -#5X18" 0 PAVING N OR NON -WOVEN FILTER IC SECURING DEVICE 09/22 IFL DR#14 09/22 IFL DR#18 HANDICAPPED SYMBOL 1/8" ALUMINUM PANEL SCREEN PRINT SYMBOL COLORS SELECTED SELECTED PER OKEECHOBEE COUNTY PARKING CODE FENCE POST (SPACING 8'-0" CE TO CL ) FABRIC TO BE SECURED TO POST WITH METAL FASTENERS & REINFORCEMENT BETWEEN FASTENER AND FABRIC. SILT ACCUMULATION - GRADE DIG 6" DEEP TRENCH, BURY BOTTOM FLAP, TAMP IN PLACE. IAL WIRE FENCE BEHIND FABRIC FOR "SUPER" SILT FENCE. OPTIONAL WIRE FENCE BEHIND FABRIC FOR "SUPER" SILT FENCE. z 0 N 0 N NOTES: 1. 1. FENCE POSTS SHALL BE SPACED 8 FEET CENTER -TO -CENTER OR CLOSER. THEY SHALL EXTEND AT LEAST 2 FEET INTO THE GROUND AND EXTEND AT LEAST 2 FEET ABOVE GROUND (FIG. 23-2). POSTS SHALL BE CONSTRUCTED OF HARDWOOD WITH A MINIMUM DIAMETER THICKNESS OF 1 1/2 INCHES 2. "SUPER" SILT FENCE -A METAL FENCE WITH 6 INCH OR SMALLER MESH OPENINGS AND AT LEAST 2 FEET HIGH MAY BE UTILIZED, FASTENED TO THE FENCE POSTS, TO PROVIDE REINFORCEMENT AND SUPPORT TO THE GEOTEXTILE FABRIC. POSTS MAY BE SPACED LESS THAN 8 FEET ON CENTER AND MAY BE CONSTRUCTED OF HEAVIER WOOD OR METAL AS NEEDED TO WITHSTAND HEAVIER SEDIMENT LOADING. THIS PRACTICE IS APPROPRIATE WHERE SPACE FOR OTHER PRACTICES IS LIMITED AND HEAVY SEDIMENT LOADING IS EXPECTED, "SUPER" SILT FENCE IS NOT TO BE USED IN PLACE OF PROPERLY DESIGNED DIVERSIONS (PG. 15-1) WHICH MAY BE NEEDED TO CONTROL SURFACE RUNOFF RATES AND VELOCITIES. 3. A GEOTEXTILE FABRIC, RECOMMENDED FOR SUCH USE BY MANUFACTURER, SHALL BE BURIED AT LEAST 6 INCHES DEEP IN THE GROUND. THE FABRIC SHALL EXTEND AT LEAST 2 FEET ABOVE THE GROUND. THE FABRIC MUST BE SECURELY FASTENED TO THE POSTS USING A SYSTEM CONSISTING OF METAL FASTENERS (NAILS OR STAPLES) AND A HIGH STRENGTH REINFORCEMENT MATERIAL (NYLON WEBBING, GROMMETS, WASHERS ETC.) PLACED BETWEEN THE FASTENERS AND THE GEOTEXTILE FABRIC. THE FASTENING SYSTEM SHALL RESIST TEARING AWAY FROM THE POST. THE FABRIC SHALL INCORPORATE A DRAWSTRING IN THE TOP PORTION of THE FENCE FOR ADDED STRENGTH. 4. SEDIMENT SHALL BE REMOVED FROM THE UPSTREAM FACE of THE BARRIER WHEN IT HAS REACHED A DEPTH OF 1/2 THE BARRIER HEIGHT. J. REPAIR OR REPLACE BARRIER (FABRIC, POSTS, BALES ETC.) WHEN DAMAGED. EXIST. PAV'MT.' 6. BARRIERS SHALL BE INSPECTED DAILY FOR SIGNS OF DETERIORATION AND SEDIMENT REMOVAL. 24 WHITE 6' MIN STOP BAR 12' MAX = _ & BASE = III 111 - C E DETAIL 02 N.T.S.STOP SIGN LOCATION DETAIL 09/22 FL CD 7 SAW CUT D ETA I L 09/22 F CD 1 .S. NEWLINE N.T.S. NEWLINES N.T.S. NEWLINE FINISHED GRADE A DENSITY TEST SHALL BE PERFORMED BETWEEN BEGIN TESTING IN THE FIRST FOOT _ x III -III AND THEN EVERY 2 FEET TO III I III_ WITHIN 2 FEET OF SUBGRADE /:l \MA No HANDICAPPED SIGN _�_ BACKFILL SHALL BE PLACED IN 12" MAX. II -II III LAYERS, EACH LAYER TO BE MECHANICALLY II- TAMPED TO A MINIMUM 100% OF MAX. �� Q DENSITY AS DETERMINED BY AASHTO _III EfE m o WHEEL STOP I I METHOD T-99 FOR NON -FLEXIBLE PIPE o w w (RCP, DIP) AND 98% FOR FLEXIBLE PIPE. ICI > 0 Q Q z < HANDICAP zo CAD =n m 0 PAVEMENT 12" MAX. 12" MAX. o w o � w STRIPING PER > Q m Q > w Qz o FDOT INDEX 17346 x � � w O J U= N w 0000 00000 00000000( z w w0 o co 0000 O 000000< N o�Qm w< (� /-\ /-\ �O�O ww Lj ww = ww6= 00 O O O O O <=) Lj o1 HANDICAPPED SYMBOL O O O O O O > z J w Q C� 000 000�� 6" STRIPES (TYP.) INVERT O O O O O O m 0 5'0" 12 1 0 17'0 \/\// 10 //�/��IIII��-IIIII III��II II HANDICAPPED PARKING SIGN HANDICAPPED PARKING HAND PLACED SELECT MATERIAL (MAXIMUM 6" LAYERS) COMPACTED WITH MECHANICAL TAMPERS NOTE: NOTE: ALL PAVED PARKING STALLS ARE TO BE DOUBLE STRIPED. IF PIPE IS NOT UNDER PROPOSED PAVEMENT, BACKFILL SHALL BE COMPACTED TO A FIRMNESS APPROXIMATELY EQUAL TO THAT OF THE SOIL ADJACENT TO THE PIPE TRENCH. HANDICAPPED PARKING SIGNAGE/STRIPING DETAIL o9/22 FL GD 13 TYPICAL TRENCH DETAIL PN9 T FL DR 8 N T_S. NFWI INFS .TS. NFWI INFS SILT FEN Ln PARKING BY DISABLED PERMIT ONLI VAN ACCESSIBLE /$250 FINE 2" SO. ALUMINUM POST FINISH AS PER SPECIFICATIONS FINISHED GRADE III EARTH 1=1III III II CONCRETE FOOTING 6" 3,000 PSI CONCRETE (FIBER REINFORCED) 12" STABILIZED SUB -GRADE FBV OF OF 75 PSI COMPACTED TO 98% MAX. DENSITY PER AASHTO T-180 METHOD. SUB -GRADE SHALL MEET LBR 40 CONCRETE PAVEMENT TYPICAL WHEELSTOP DETAIL 09/22 FL CD 9 SECTION 09/22 FL N.T.S. NEWLINES N.T.S. NE 6" WHITE STRIPE 20' OVERALL STALL LENGTH n ---WHEEL STOP OR FACE OF CURB 0 2' 6" WHITE STRIPE EDGE OF PAVEMENT OR BACK OF CURB * FOR PAVED AREAS TYPICAL PARKING STALL 0.TS2 NEWLINE FL SE 1 FINISHED GRADE \ 1 /4„R 1 /4„R 1/2" (TYP.) D 4 \ \ SEE NOTE NO. 5 / D N \ H J z SPRING n INITIAL BACKFILL 1/2" PRE -MOLDED 3/16" SAW CUT JOINT LINE \ Q EXPANSION JOINT MATERIAL MAYBE SUBSTITUTED mg OF LAUNCHING LL' EXPANSION JOINTS CONTRACTION JOINTS PIPE BEDDING 6" MIN. IF REQUIRED \ FOUNDATION SEE PLANS FOR WIDTH (MAY NOT BE 3,000 PSI CLASS I REQUIRED) SLOPE PER CONCRETE CROSS SECTIONS 6" - 2 % NOTES: 0 1. IN CERTAIN SOIL CONDITIONS A FOUNDATION MAY BE REQUIRED. _---COMPACT SUBGRADE TO 95% OF THE MAXIMUM DENSITY AS 2. BEDDING IS REQUIRED PRIMARILY TO BRING THE TRENCH BOTTOM UP TO DETERMINED BY AASHTO T-99 GRADE. BEDDING MATERIALS SHALL PROVIDE A UNIFORM AND ADEQUATE LONGITUDINAL SUPPORT UNDER THE PIPE. 3. HAUNCHING MATERIAL SHALL BE HAND PLACED TO THE SPRINGLINE OF THE PIPE. MATERIAL SHALL BE CONSOLIDATED UNDER THE PIPE AND HAND NOTES: TAMPED TO PROVIDE ADEQUATE SIDE SUPPORT. 1. PROVIDE EXPANSION JOINTS 20' CENTER TO CENTER, AT PC & PT OF 4. INITIAL BACKFILL MATERIAL SHALL BE HAND PLACED TO 12" ABOVE THE TOP CURVES, JUNCTIONS OF EXISTING & NEW SIDEWALKS, AND WHERE SIDEWALK OF PIPE. THE SOIL SHALL BE COMPACTED. ABUTS CURBS, DRIVEWAYS & SIMILAR STRUCTURES. 5. BACKFILL SHALL BE COMPACTED TO 100% OF MAX. DENSITY AS PER 2. PROVIDE CONTRACTION JOINTS 5' CENTER TO CENTER. AASHTO T-99, TO A POINT 30" BELOW PROPOSED PROFILE GRADE OR EXISTING GRADE. THE FINAL 30" OF BACKFILL SHALL BE COMPACTED TO 3. SOD SHALL BE PLACED BELOW EDGE OF SIDEWALK TO ALLOW DRAINAGE. 98% OF MAX. DENSITY AS PER AASHTO T-180. 4. SIDEWALK WITH 6"X6" NO. 10 WELDED WIRE MESH THROUGHOUT THIS 6. DENSITY TEST SHALL BE PREFORMED AT AREAS DETERMINED BY THE PROJECT. UTILITIES ENGINEER OR PERMIT AGENCY HAVING JURISDICTION, AT THE CONTRACTOR'S EXPENSE. BACKFILLING REQUIREMENTS 09/22 FL DR 12 TYPICAL SIDEWALK 09/22 FL CD 8 N.T.S. NEWLINES N.T.S. NEWLINES EDGE OF PAVEMENT NEW PAV'MT. SAW CUT EXIST. EDGE OF PAVEMENT & BASE 2 PAV'MT. 36" X 36" (TYP) zx n� -- - - 6' MIN J 00 oN 12' MAX ~oEfE z = --I--- STRUCTURES AT THE FOLLOWING LOCATIONS THIS DOCUMENT, TOGETHER WITH THE CONCEPTS AND DESIGNS PRESENTED HEREIN, AS AN INSTRUMENT OF SERVICE, IS INTENDED ONLY FOR THE SPECIFIC PURPOSE AND CLIENT FOR WHICH IT WAS PREPARED. REUSE OF AND IMPROPER RELIANCE ON THIS DOCUMENT WITHOUT WRITTEN AUTHORIZATION AND ADOPTION BY STEVEN L° DOBBS, P.E., SHALL BE WITHOUT LIABILITY TO NEWLINES ENGINEERING do SURVEY AND STEVEN L° DOBBS ENGINEERING, LLC. MINOR SUBDIVISION PLAN DETAILS - 1 GLENWOOD PARK LYING IN SEC 15, TOWNSHIP 37 SOUTH, RANGE 35 EAST, OKEECHOBEE CITY, FLORIDA JDNEWLII�ES ANn CONSHI I AIN I b LLC cc STEVEN L. DOBBS, P.E. PROJECT NO. FL22024 DRAWN BY J M SCALE AS SHOWN DATE 2022-1 1-17 FLORIDA CERTIFICATE OF AUTHORIZATION NO. 00029206 DATE STEVEN L. DOBBS ENGINEERING, LLC SHEET 1062 JAKES WAY OKEECHOBEE, FL 34974, PHONE (863) 824-7644 C600 OF 19 PROPERTY LINE CHECK VALVE (RESIDENTIAL) METER BOX VALVE BOXY ` PRESSURE TEST LIMIT PAVEMENT ISOLATION VALVE W/ VALVE BOX AND METER BY OKEECHOBEE UTILITY AUTHORITY TYPICAL ALL SERVICES Q 24" 24" z PROPERTY MIN. MIN. Q LINE (TYP) ANGLE STOP � METER (LOCKING TYPE 3: o --f f-A, Lj_ 3/4 OR 1" MIN. SERVICE z 0ISOLATION VALVE � LINE POLYETHYLENE TUBING o z SHORT SERVICES ONLY z x 7� w WATER o w N MAIN 0" OR 45' ANGLE CENTER & SEAL ENDS (TYP) -- CORP STOP FOR INSTALLATION OF SERVICES UNDER EXISTING OR PROPOSED PAVEMENT AND RIGHTS OF WAY, INSTALL GALVANIZED STEEL (2" MIN., 4" MAX.) SCH. 40 PVC OR HDPE CASING NOTES DOUBLE STRAP SADDLE. (CORPORATION STOP IS REQUIRED) 1. SUCCESSIVE TAPS INTO THE WATER MAIN SHALL BE SPACED A MINIMUM OF 18" APART. TAPS SPACED BETWEEN 18" TO 48" SHALL BE OFFSET TO EACH SIDE OF THE MAIN, OR OFFSET 45°. 2. METER BOX SHALL BE SET TO CONFORM TO FINISHED GRADE ADJACENT TO PROPERTY LINE. METER BOX SHALL NOT BE PLACED IN SIDEWALK OR DRIVEWAY AREAS. SERVICE LINES SHALL NOT BE PLACED UNDER DRIVEWAYS. 3. SERVICE CONNECTION TUBING TO BE POLYETHYLENE AND MAXIMUM LENGTH OF 100'. 4. ALL 5/8 " & 1" METERS REQUIRE A 3/4 " & 1" LOCKING ANGLE METER VALVE RESPECTIVELY. 5. AFTER METER INSTALLATION, INSTALL LINE VALVE IN CUSTOMER SERVICE LINE. 6. DIMENSION "A" - 7" (5/8" X 3/4" METER) = 8" (1" METER) 7. CONTRACTOR TO PROVIDE & INSTALL ENTIRE WATER SERVICE UP TO ANGLE STOP INCLUDING METER BOX 8. QUA TO PROVIDE AND INSTALL METER. 9. QUA TO INSTALL IN -LINE DUAL CHECK VALVE (RESIDENTIAL). 10. QUA TO INSTALL ISOLATION VALVE & BOX ON CUSTOMER SIDE OF METER INSTALLATION. * 36" MIN. IN STATE ROAD R/W & UNDER ASPHALT TYPICAL SERVICE CONNECTION (UNDERGROUND) OF 5/8" x 3/4" OR 1 " METER 1/4" ALUMINUM POLLUTION RETARDING BAFFLE TOP EL.= 26.50, BOTTOM EL.- 25.00 BOLTED 6" ON CENTER W/ MASONRY BOLTS SEALED W/RAM NEK SEALER. 18" ADS N-12 INV. EL.- 23.00 L--J SIDE VIEW O 3" DIAMETER 0 BLEEDER ORIFICE INV. EL.= 25.00 2' X 2'X 4" CONCRETE SLAB @ TOP EL. 24.50 3/4 " SERV ANGLE STOP (TYP) METER SINGLE SERVICE CHECK VALVE LINE (TYP) CORP STOP SERVICE LINE NCH DOUBLE SERVICE RVICE "Y" E LINE VE (TYP) 'P) z a w Q DOUBLE STRAP TAPPING SADDLE - AWWA (TYP) z Q w w Q NOTES: 1. AUTHORIZED SERVICE LINE MATERIAL SHALL BE POLYETHYLENE TUBING. 2. MULTIPLE SERVICE/METER INSTALLATIONS OF MORE THAN 4 METERS PER SERVICE AND SERVICE LINES LARGER THAN 2" IN DIAMETER SHALL BE HANDLED ON AN INDIVIDUAL BASIS. 3. NO FITTINGS BETWEEN CORP. STOP & ANGLE VALVE OR CORP. STOP & "Y" BRANCH FOR MULTIMETER INSTALLATIONS. TYPICAL SERVICE FOR MULTIPLE SERVICES (TWO OR 10/15 QUA #1 MORE) N T C NF\NI INF7C FRONT VIEW GRATE EL.= 26.50 1/4" ALUMINUM POLLUTION RETARDING BAFFLE INV. EL.= 25.00 IAMETER BLEEDER CE INV. EL.= 25.00 ADS N-12 RT EL.= 23.00 TURE BOT. EL.= 21.50 1/4" ALUMINUM POLLUTION RETARDING BAFFLE TOP EL.= 26.70, BOTTOM EL.- 25.00 BOLTED 6" ON CENTER W/ MASONRY BOLTS SEALED W/RAM NEK SEALER. 18" ADS N-12 INV. EL.- 23.00 SIDE VIEW O 12" O O 0 QUA /\nL ITO A r'Tno (lI IA MAIN NOTES 1. WATER MAIN TO BE PRESSURE TESTED AND DISINFECTED ACCORDING TO FDEP REGULATIONS, AWWA STANDARDS AND QUA REQUIREMENTS. 2. BACTERIOLOGICAL TESTING IS TO BE PERFORMED BY CONTRACTOR WITH PRIOR NOTIFCATION OF TESTING TO QUA PERSONNEL. 3. DO NOT REMOVE TEMPORARY CONNECTION UNTIL ALL TESTING HAS BEEN COMPLETED. 4. PROVIDE ALL NECESSARY THRUST BLOCKS OR OTHER RESTRAINTS. 5. FILLING AND FLUSHING LOCATIONS SHALL BE DETERMINED BY THE CONTRACTOR AND WITH APPROVAL OF ENGINEER AND/OR QUA. 6. MAIN LINE VALVE TO BE OPENED BY QUA PERSONNEL ONLY AND OPENED FOR CANNON FLUSHING OF NEW PIPING SYSTEM. 3" DIAMETER BLEEDER ORIFICE INV. EL.= 25.00 2' X 2'X 4" CONCRETE SLAB @ TOP EL. 24.50 FILLING, DISINFECTING AND TESTING DETAILS FRONT VIEW GRATE EL.= 26.70 1/4" ALUMINUM POLLUTION RETARDING BAFFLE INV. EL.= 25.00 IAMETER BLEEDER CE INV. EL.= 25.00 ADS N-12 RT EL.= 23.00 TURE BOT. EL.= 21.50 10/15 IOUA #10 WATER SMOOTH, UNTHREADED 0.5" HOSE BIB FOR BACTERIA SAMPLES 12" MINIMUM L.VIV I I\VL VALVE NOTES i 2" PVC SCH 80 OR BRASS FORMULA FOR ESTIMATING RATE OF DISCHARGE Q = 2.83 d' SX WHERE: Q = DISCHARGE IN GALLONS PER MINUTE d = INSIDE DIAMETER OF DISCHARGE PIPE d, Sx, Sy = MEASURED IN INCHES 1. REFERENCE, AWWA C651. 2. THIS DETAIL APPLIES TO PIPES UP TO AND INCLUDING 8" DIAMETER. LARGER SIZES SHALL BE HANDLED ON A CASE BY CASE BASIS. 3. PIGGING OF LINES IS AN ACCEPTABLE METHOD OF CLEANING. 4. ABOVE GROUND PIPING TO BE REMOVED UPON COMPLETION OF TESTING. VIN. VVV ULL JII\nl Jf"�VVLL NOTES: 1. SAMPLE POINT SHOULD BE ON A SERVICE LINE OR FIRE HYDRANT IF POSSIBLE. 2. SAMPLE POINT TO BE REMOVED BY CONTRACTOR AFTER PROJECT IS ACCEPTED. FLUSHING DETAILS f\T i 0 QUA #9A C I\IC\All II\ICC CONTROL STRUCTURE CS-1 TYPE "C" INLET (MODIFIED) 09/22 FL DR#2 i CONTROL STRUCTURE CS-2 TYPE "C" INLET (MODIFIED) 09/22 FL#-^� SAMPLING POINT (ON MAIN)0/15 !'QUA #7 THIS DOCUMENT, TOGETHER WITH THE CONCEPTS AND DESIGNS PRESENTED HEREIN, AS AN INSTRUMENT OF SERVICE, IS INTENDED ONLY FOR THE SPECIFIC PURPOSE AND CLIENT FOR WHICH IT WAS PREPARED. REUSE OF AND IMPROPER RELIANCE ON THIS DOCUMENT WITHOUT WRITTEN AUTHORIZATION AND ADOPTION BY STEVEN L. DOBBS, P.E., SHALL BE WITHOUT LIABILITY TO NEWLINES ENGINEERING do SURVEY AND STEVEN L. DOBBS ENGINEERING, LLC. MINOR SUBDIVISION PLAN DETAILS - 2 GLENWOOD PARK LYING IN SEC 15, TOWNSHIP 37 SOUTH, RANGE 35 EAST, OKEECHOBEE CITY, FLORIDA JDNEWLII�ES ANn CONSHI I AIN I b LLC cc STEVEN L. DOBBS, P.E. PROJECT NO. FL22024 DRAWN BY J M SCALE AS SHOWN DATE 2022-1 1-17 FLORIDA CERTIFICATE OF AUTHORIZATION NO. 00029206 DATE STEVEN L. DOBBS ENGINEERING, LLC SHEET 1062 JAKES WAY OKEECHOBEE, FL 34974, PHONE (863) 824-7644 C601 OF 19 GROUND OR PAVEMENT SURFACE UNDISTURBE SOIL FIRE HYDRANT USE ANCHOR COUPLING MECHANICAL JOINT TEE VARIES PIPING TO BE MECHANICAL JOINT RESTRAINED 4 1/2 " PUMPER NOZZLE FACING AS DIRECTED, AND TWO 2-1/2" HOSE NOZZLES. O R 18" MAX. o x z x N FINISHED GRADE VALVE SETTING (SEE DETAIL) 18" /6" R.S.G.V. 6" D.I.P. OR PVC C-900 5 1 /4 " VALVE OPENING UNDISTURBED SOIL ReIal 1. HYDRANT SHALL BE INSTALLED PLUMB AND TRUE. 2. THE MODEL COLOR TO BE SAFETY YELLOW, HYDRANT SHALL BE PER QUA REQUIREMENTS. 3. VALVE SHALL BE PLACED ADJACENT TO MAIN, TIED TO TEE. 4. ANCHOR TEES ARE PERMITTED. 5. ALL HYDRANTS SHALL BE TEE'D OFF MAINS. 6. HYDRANTS SHALL NOT BE PLACED IN SIDEWALKS, ROADWAYS OR BIKEPATHS. 7. MEGALUGS ON ALL FITTINGS. 8. HYDRANTS SHALL BE BAGGED UNTIL SYSTEM IS PLACED IN SERVICE. LOCATION OF PUBLIC WATER SYSTEM MAINS IN ACCORDANCE WITH F.A.C. RULE 62-555.314 OTHER PIPES HORIZONTAL SEPERATION CROSSING (1) JOINT SPACING @ CROSSINGS (FULL JOINT CENTERED) WATER MAIN ALTERNATE 3 FT. WATER MAIN 12 INCHES IS THE MINIMUM STORM SEWER, MINIMUM EXCEPT FOR WATER MAIN STORMWATER FORCE MAIN, STORM SEWER, THEN 6 RECLAIM WATER (2) 3 FT. INCHES IS THE MINIMUM MINIMUM AND 12 INCHES IS if PREFERRED WATER MAIN ALTERNATE 3 FT. WATER MAIN MINIMUM VACUUM SANITARY SEWER 10 FT. PREFERRED 12 INCHES PREFERRED 6 INCHES MINIMUM WATER MAIN 3 FT. MINIMUM WATER MAIN ALTERNATE 6 FT. GRAVITY OR PRESSURE SANITARY SEWER, SANITARY SEWER FORCEMAIN RECLAIM WATER (4) WATER MAIN 10 FT. PREFERRED 116 FT. MINIMUM 12 INCHES IS THE MINIMUM EXCEPT FOR GRAVITY SEWER, THEN 6 INCHES IS THE MINIMUM AND 12 INCHES IS PREFERRED MINIMUM WATER MAIN ON -SITE SEWAGE 10 FT. - - - --- TREATMENT & DISPOSAL MINIMUM FAC RULE 62-555.314 NOTES: 1. WATERMAIN TO CROSS OVER CONFLICT PIPES WHEREVER POSSIBLE, MAINTAINING 30 INCHES COVER AND 6 INCHES SEPARATION AS MINIMUMS. WHEN WATER MAIN MUST BE BELOW OTHER PIPE, THE MIN. SEPARATION IS 12 INCHES. 2. RECLAIMED WATER REGULATED UNDER PART III OF CHAPER 62-610, F.A.C. 3, 3 FT FOR GRAVITY SANITARY SEWER WHERE THE BOTTOM OF THE WATER IS LAID AT LEAST 6 INCHES ABOVE THE TOP OF THE GRAVITY SANITARY SEWER. 4, RECLAIMED WATER NOT REGULATED UNDER PART III OF CHAPTER 62-610, F.A.C. NOTES: A. THESE METHODS ARE TO BE USED WHEN INSUFFICIENT COVER EXISTS TO ALLOW PRESSURE PIPE TO CROSS ABOVE CONFLICT PIPE WITH 6 INCHES VERTICAL SEPARATION AND MAINTAIN 30 INCHES COVER TO FINISHED GRADE. B. FITTINGS SHALL BE RESTRAINED WITH MECHANICAL RESTRAINTS (MEGALUG). IN ACCORDANCE WITH OUA STANDARD DETAILS. C. THE DEFLECTION TYPE CROSSING IS PREFERRED. D. DO NOT EXCEED 75% OF MANUFACTURERS RECOMMENDED MAXIMUM JOINT DEFLECTION. E. MECHANICALLY RESTRAIN ALL FITTINGS. AS PER MANUFACTURERS RECOMMENDATION AND OUA STANDARD DETAILS. WATER MAIN - SANITARY SEWER CONFLICT 1-24"� N PLAN CAST IRON COVER MARKED "WATER", "SEWER" OR "FIRE" TOP OF PAVEMENT 4" 5-1/4" C.I. ADJUSTABLE VALVE BOX (INSIDE SCREW TYPE) D/I OR C-900 P.V.C. SQUARE NUT MECHANICAL JOINT VALVE CONCRETE COLLAR POUR CONCRETE COLLAR TO GRADE IN SODDED AREAS NOTES: JURISDICTIONAL LINE (IF APPLICABLE) SILT SCREEN RESTORATION & GRASSING PAYMENT LIMITS 12" BENCH WIDT� 12" 12„ 12„ v11N. MAX. i PIPE O.D. MAX. \0� o UNDISTURBED EARTH BACKFILLED & COMPACTED TO 98% MAX. DENSITY AT +/- 2% OF OPTIMUM MOISTURE DETERMINED BY MODIFIED PROCTOR TEST AASHTO T-180/ASTM D 1557, IN 12" LOOSE THICKNESS LIFTS. BACKFILLED & COMPACTED TO 98% MAX. DENSITY AT +/- 2% OF OPTIMUM MOISTURE DETERMINED BY MODIFIED PROCTOR TEST AASHTO T-180/ASTM D 1557, IN 6" LOOSE THICKNESS LIFTS. NOTES: 1. SEWER RAIN GUARDS SHALL BE INSTALLED ON ALL MANHOLES. 2. SEWER RAIN GUARDS SHALL BE AS MANUFACTURED BY FOSROC-PRECO INDUSTRIES, INC., OR SOUTH WEST PACKING AND SEALS, INC., OR APPROVED EQUAL. 1. BACKFILL MATERIALS SHALL CONSIST OF CLEAN EARTH FILL COMPRISED OF SAND, SAND AND CLAY, GRAVEL, CRUSHED ROCK OR OTHER MATERIALS FROM GROUPS A-1, A-2 OR A-3, AASHTO CLASSIFICATION, FREE FROM ORGANIC MATTER AND VEGETATION, DEBRIS, LARGE CLODS OF EARTH OR STONES. UNSUITABLE IN -SITU MATERIALS SUCH AS MUCK, DEBRIS, LARGE ROCKS AND ROOTS SHALL BE REMOVED AND DISPOSED OF BY THE CONTRACTOR. 2. THE PIPE SHALL BE FULLY SUPPORTED ALONG ENTIRE LENGTH. MANHOLE RAIN GUARD 10/15 QUA #28 3. THE PIPE TRENCH SHALL REMAIN DRY DURING PIPE LAYING OPERATIONS. N.T.S. NEWLINES 15 x 7N 4. ALL TRENCH WORK SHALL CONFORM TO LATEST STANDARDS AS SET FORTH BY THE FLORIDA TRENCH SAFETY ACT AND OR OSHA. CD CO 5. FOUR INCH WIDE DETECTABLE TAPE SHALL BE PLACED APPROXIMATELY 12"-18" BELOW FINISHED GRADE AND DIRECTLY ABOVE ALL PRESSURE PIPING. TAPE, WORDING AND COLOR SHALL CONFORM TO CITY STANDARDS. 6. TRAFFIC LANE CLOSURES, MOT PLANS AND ROADWAY REPAIRS MATERIALS SHALL BE PER DIRECTION OF ROAD OWNER. CONTRACTOR TO INQUIRE WITH OWNER ABOUT REQUIREMENTS PRIOR TO BID. 7. 3M LOCATOR BALLS SHALL BE INSTALLED AT EACH FITTING IN THE PIPE LINE CHANGING DIRECTION AND AT EACH CONCRETE CONNECTION. BRICKS FOR 8. 3M LOCATORS TO BE PROVIDED BY DEVELOPER AS SPECIFIED BY O.U.A. PADS NOTE: VALVE NUT EXTENSION IS REQUIRED ON ALL VALVES WITH MORE THAN 36" OF COVER. EXTEND NUT TO WITHIN 18" OF VALVE BOX RIM. PROVIDE SOLID BRICK PAD FOR VALVE BOX TO SIT ON. ouA, TYPICAL VALVE SETTING ASPHALTIC CONCRETE OVERLAY AREA SEE DRAWINGS FOR LIMITS SURFACE REPLACEMENT W+4' _I 6TOP OF TRENCH WIDTii� 2" MIN. "'III I W I T EXISTING BASE' PROPOSED BASE 2T (12" MIN.) MAX, PIPE O.D. I MAX. o UNDISTURBED EARTH EXISTING ASPHALT SURFACE BACKFILLED & COMPACTED TO 98% MAX. DENSITY AT +/- 2% OF OPTIMUM MOISTURE DETERMINED BY MODIFIED PROCTOR TEST AASHTO T-180/ASTM D 1557. IN 6" LOOSE THICKNESS LIFTS. NOTES: 1. BACKFILL MATERIALS SHALL CONSIST OF CLEAN EARTH FILL COMPRISED OF SAND, SAND AND CLAY, GRAVEL, CRUSHED ROCK OR OTHER MATERIALS FROM GROUPS A-1, A-2 OR A-3, AASHTO CLASSIFICATION, FREE FROM ORGANIC MATTER AND VEGETATION, DEBRIS LARGE CLODS OF EARTH OR STONES. UNSUITABLE IN -SITU MATERIALS SUCH AS MUCK, DEBRIS, LARGE ROCK AND ROOTS SHALL BE REMOVED AND DISPOSED BY THE CONTRACTOR. 2. THE PIPE SHALL BE FULLY SUPPORTED ALONG ENTIRE LENGTH. 3. THE PIPE TRENCH SHALL REMAIN DRY DURING PIPE LAYING OPERATIONS. 4. ALL TRENCH WORK SHALL CONFORM TO LATEST STANDARDS AS SET FORTH BY THE FLORIDA TRENCH SAFETY ACT AND OR OSHA. 5. FOUR INCH WIDE DETECTABLE TAPE SHALL BE PLACED APPROXIMATELY 12"-18" BELOW FINISHED GRADE AND DIRECTLY ABOVE ALL PRESSURE PIPING. TAPE, WORDING AND COLOR SHALL CONFORM TO CITY STANDARDS. 6. BACKFILL SHALL BE COMPACTED IN 6" LAYERS WITH MECHANICAL TAMPERS FOR THE FULL WIDTH OF THE TRENCH AND UP TO THE BOTTOM OF THE ROADWAY BASE. PARTICULAR ATTENTION MUST BE GIVEN TO THE ADEQUATE COMPACTION OF THE HAUNCHES OF THE PIPE. THE BACKFILL SHALL BE COMPACTED TO 98% AASHTO T-180/ASTM D 1557 TAKEN AT THE SPRING LINE, AT ONE FOOT ABOVE THE CROWN OF THE PIPE, AND EVERY FOOT VERTICALLY THEREAFTER. 7. BASE MATERIAL SHALL BE THE SAME TYPE AS THE MATERIALS REMOVED. 8. SURFACE REPLACEMENT SHALL BE F.D.O.T. MIX TO MATCH EXISTING PAVEMENT, WITH A THICKNESS EQUAL TO THE EXISTING OR 2" WHICHEVER IS GREATER. 9. PAVEMENT JOINTS SHALL BE MECHANICALLY SAWED BUTT JOINTS, HEATED, RAKED AND SPRAYED WITH A REJUVENATING AGENT. THE PATCH AREA SHALL BE A SMOOTH PLANE SUCH THAT A STRAIGHT EDGE PLACED ACROSS THE PATCH, PARALLEL TO THE TRAFFIC FLOW AND EXTENDING TO UNDISTURBED PAVEMENT SHALL SHOW NO MORE THAN 1/4" IRREGULARITY IN ANY 15 FT. SECTION. ANY IRREGULARITY SHALL BE CORRECTED IN ACCORDANCE WITH F.D.O.T. SPECIFICATIONS. 10. "COLD PATCH" SHALL BE USED FOR TEMPORARY REPAIRS ONLY, AND FOR A PERIOD NOT TO EXCEED 30 DAYS. 11. TRAFFIC LANE CLOSURES, MOT PLANS AND ROADWAY REPAIRS MATERIALS SHALL BE PER DIRECTION OF ROAD OWNER. CONTRACTOR TO INQUIRE WITH OWNER ABOUT REQUIREMENTS PRIOR TO BID. 12. 3M LOCATOR BALLS SHALL BE INSTALLED AT EACH FITTING IN THE PIPE LINE CHANGING DIRECTION AND AT EACH CONNECTION. 13. 3M LOCATORS TO BE PROVIDED BY DEVELOPER AS SPECIFIED BY O.U.A. 15 QUA 16 TRENCH REPAIR DETAILS PAVED AREAS S. NEWLINES 1n10/15 I QUA. #131 TYPICAL TRENCH DETAIL R/W OR EASEMENT LINE VALVE & VALVE BOX VALVE & VALVE BOX ROAD SURFACE OR OTHER AREA TO BE - DRILLED EXIST. GRADE \, \\\ADAPTER\ �\ 2, �_ a_MIN. x o MIN. HDPE \/AI \/r PIPELINE HDPE PIPE INE OUA 12 15 IOUA #1 ADAPTER PERPENDICULAR CONNECTION PLAN VIEW a HDPE-MJ ADAPTER 4° MA SLOPE ZING D.I.P. OR_j P.V.C. PIPELINE STRAIGHT RUN CONNECTION MJ FITTING NOTES: 1. DIRECTIONAL DRILLS SHALL BE COMPLETED USING DR11 HDPE PIPE, DIP SIZE: FOR WATER AND SANITARY FORCE MAIN IPS SIZE: FOR VACUUM SEWER. 2. ALL DIRECTIONAL DRILLS SHALL BE AT A DEPTH OF 1OX PIPE DIAMETER BELOW THE ROADWAY SURFACE OR 4' WHICHEVER IS GREATER. 3. ALL HDPE MUST BE COLOR CODED (SAFETY BLUE -WATER, SAFETY GREEN FOR SEWER AND PANTONE PURPLE FOR RECLAIMED WATER); BUTT FUSION WELDED; AND CONNECTED WITH HDPE-MJ ADAPTER. 4. 10 GUAGE SOLID COPPER LOCATING WIRES SHALL BE TAPED TO PIPE FROM VALVE TO VALVE AT A SPACING NO GREATER THAN 5 FEET AND PULLED WITH THE PIPE. SEE D17 FOR ADDITIONAL DETAILS. 5. GRAVITY SEWER BORES AS PREAPPROVED BY QUA. 1^10/15 I QUA. #19 DIRECTIONAL DRILLING DETAIL THIS DOCUMENT, TOGETHER WITH THE CONCEPTS AND DESIGNS PRESENTED HEREIN, AS AN INSTRUMENT OF SERVICE, IS INTENDED ONLY FOR THE SPECIFIC PURPOSE AND CLIENT FOR WHICH IT WAS PREPARED. REUSE OF AND IMPROPER RELIANCE ON THIS DOCUMENT WITHOUT WRITTEN AUTHORIZATION AND ADOPTION BY STEVEN L. DOBBS, P.E., SHALL BE WITHOUT LIABILITY TO NEWLINES ENGINEERING do SURVEY AND STEVEN L. DOBBS ENGINEERING, LLC. MINOR SUBDIVISION PLAN DETAILS -3 GLENWOOD PARK LYING IN SEC 15, TOWNSHIP 37 SOUTH, RANGE 35 EAST, OKEECHOBEE CITY, FLORIDA JDNEWLII�ES ANn CONSHI I AIN I b LLC cc STEVEN L. DOBBS, P.E. PROJECT NO. FL22024 DRAWN BY J M SCALE AS SHOWN DATE 2022-1 1-17 FLORIDA CERTIFICATE OF AUTHORIZATION NO. 00029206 DATE STEVEN L. DOBBS ENGINEERING, LLC SHEET 1062 JAKES WAY OKEECHOBEE, FL 34974, PHONE (863) 824-7644 C602 OF 19 FINISH GRADE UNPAVED SURFACE SEE D-25 FOR STANDARD M/H FRAME 2" TYP. AND COVER PAVED SURFACE N X Q PRECAST GRADE RINGS OR o 24" MIN. SOLID CORE BRICK PLASTERED INSIDE & OUTSIDE w/ 1 " OF PORTLAND CEMENT. z Q 0 co 0 1 1 ° Qo ° ° Q PRECAST MANHOLES SHALL w COMPLY WITH ASTM C 478, Q LATEST REVISION, UNLESS > n, r- OTHERWISE NOTED w w MANHOLE JOINT SHALL CD COMPLY WITH ASTM C ° ° Q m 443, LATEST REVISION = �. 0 o_ o #4 AT 12" O.C.E.W. (MIN.) _ NEOPRENE MAX GASKET MAX. ° SLOPE 1 "/FT. ° 8" MIN. BOTTOM RISER SECTION AND BASE SLAB TO BE MONOLITHICALLY POURED 2500 PSI CONCRETE o ° ° PIPE SUPPORT o 0 00 0 00 0 0 0 0 0 0 0 0 0 0 0 0 6" MIN. 0 0 0 0 0 3" CLEA #4 AT 12" O.C.E.W. (MIN.) 6" 6" 6" 6" MIN. MIN. 4' DIA. (MIN.) MIN. MIN. GRAVEL NOTES 1. PRECAST CONCRETE TYPE II 4000 P.S.I. 2. "RAMNEK" OR EQUAL AT ALL RISER JOINTS (1/2" THICK WITH WIDTH AT LEAST 1/2 THE WALL THICKNESS) WITH GROUT INSIDE AND OUTSIDE. 3. ALL OPENINGS SHALL BE SEALED WITH A WATERPROOF NON —SHRINKING GROUT. 4. FLOW CHANNELS SHALL BE CONSTRUCTED TO DIRECT INFLUENT INTO FLOW STREAM (SEE DETAIL). 5. LIFT HOLES ARE PERMITTED AND SHALL BE SEALED AFTER PLACEMENT OF RISER. 6. ALL PIPE HOLES SHALL BE PRECAST OR CORE —DRILLED. 7. APPROVED RUBBER BOOTS MUST BE USED WITH PVC PIPE. 8. INSIDE DROPS SHALL NOT EXCEED 2.0 FEET. 9. COAT INTERIOR & EXTERIOR WITH 2 COATS COAL TAR EPDXY, OR PRO —TECH COATING, 8 mil. MIN. DRY FILM THICKNESS EACH COAT OR QUA APPROVED EQUAL. STANDARD MANHOLE (CONCENTRIC CONE MECHANICAL THRUST RESTRAINT CHART 2 MAIN RUN, in BRANCH, in TEE LARGE SIZE SMALL LARGE REDUCER PVC DIP PVC DIP 4 4 1 1 6 4 33 21 6 4 1 1 8 4 60 38 6 6 1 1 8 6 35 22 8 4 1 1 10 4 81 51 8 6 1 1 10 6 61 39 8 8 7 5 10 8 33 21 10 6 1 1 12 4 101 64 10 8 1 1 12 6 85 54 10 10 21 14 12 8 62 39 12 6 1 1 16 4 138 87 12 8 1 1 16 6 126 79 12 12 36 24 16 8 109 68 16 6 1 1 16 12 63 40 16 8 1 1 18 4 154 97 16 16 65 43 18 6 144 91 18 6 1 1 18 8 129 81 18 8 1 1 20 4 171 107 18 18 79 52 20 6 161 101 20 6 1 1 20 8 148 93 20 8 1 1 20 12 113 71 20 20 92 61 24 4 201 127 24 6 1 1 24 6 194 122 24 8 1 1 24 8 183 115 24 24 118 78 24 12 154 97 THRUST RESTRAINT CHART BASED UPON THE FOLLOWING: PVC DIP PIPE MATERIAL, AS NOTED SP SOIL TYPE (designer to confirm) 1.5 SAFETY FACTOR (minimum) 3 TRENCH TYPE (designer to confirm) 2.5 DEPTH OF BURY, ft (designer to confirm) 150 TEST PRESSURE, psi (minimum) THE MINIMUM LENGTH OF PIPE OUT OF ANY VALVE OR FITTING SHOULD BE 20 LF. FITTINGS NOT SHOWN TO BE CALCULATED UTILIZING THE CRITERIA LISTED ABOVE AND SUBMITTED IN A SHOP DRAWING VALUES SHOWN IN CHART INDICATE LENGTH (LF) OF PIPE TO BE RESTRAINED ON EITHER SIDE OF ITEM LISTED NOTE 1:ANY CONDITION OTHER THAN THOSE LISTED ABOVE (including poly —wrapped DIP) SHALL REQUIRE REVISION OF THE TABLE IN ACCORDANCE WITH EBAA IRON, INC., RESTRAINT LENGTH CALCULATOR (V. 5.4). (http://www.ebac.com/engineering.htm or http://rcp.ebaa.com) NOTE 2:THE REVISED CHARTS SHALL BE SUBMITTED TO QUA AS A SHOP DRAWING SUBMITTAL. WATER THRUST RESTRAINT 10/15 OUA 51 N.T.S. I NEWLINEE 10/15 IDUA #27 6%4' 2'x2' CONCRETE F PLUG & CLEAN —OUT INVERTED PLUG f WITH CON( 8"x6" P.V.C. TEE—WYE 'x2'x4" CONCRETE PAD 4" MIN. INDIVIDUAL HOUSE CONNECTION —CLEAN—OUT WITH INVERTED PLUG FLUSH WITH CONCRETE —ALL ENDS TO BE PLUGGED & SEALED W/STD. STOPPERS OR PLUGS - "—PROPERTY LINE 6" X 6" X 4" X 4" STD. P.V.C. 78"x6"P.V.C. . BEND DOUBLE Y BRANCH UIRED /� 2'x2'x4" CONCRETE PAD 4" MIN. INDIVIDUAL HOUSE CONNECTION CLEAN —OUT WITH INVERTED TEE—WYE PLUG FLUSH WITH CONCRETE EASEMENT, R/W OR PROPERTY LINE CL OF MAIN SEWER. 2'x2'x4" CONCRETE PAD PLAN CLEAN —OUT WITH INVERTED PLUG FLUSH EASEMENT, R/W OR PROPERTY LINE WITH CONCRETE lllll�ll I I I I I 6" P V C SERVICE EASEMENT, R/W OR PROPERTY LINE LATERAL SLOPE 3'-0" MIN. 1/4 PER FOOT �2'x2'x4" CONCRETE PAD TYP., 1 /8 " PER FOOT MIN. CLEAN —OUT WITH INVERTED / PLUG FLUSH WITH CONCRETE 3'-0" MIN. 4 45° BEND 6" P.V.C. � SERVICE 'LATERAL 6"x4" WYE SLOPE 1/4 " PER FOOT TYP., 1 /8 " PER FOOT MIN. SINGLE SERVICE CONNECTION SECTION ---PLUG & SEAL P111rIIIt�II 6" X 6" X 4" X 4" STD. P.V.C. DOUBLE 'Y' BRANCH TO BE DETERMINED IN THE FIELD (60° MAX.) NDISTURBED EARTH DOUBLE SERVICE CONNECTION NOTES: 1. SERVICE LATERALS SHALL TERMINATE AT PROPERTY LINE AT A DEPTH OF 3 FEET, PLUGGED WATERTIGHT WITH CLEAN —OUT. 2. THE MINIMUM DIAMETER OF ALL SINGLE HOUSEHOLD CONNECTIONS SHALL BE 4"MINIMUM ALL OTHERS SHALL BE 6" AND ALL DOUBLE SERVICES 3. CONNECTION TO O.U.A. LATERAL SHALL BE MADE WITH A CLEAN —OUT AT PROPERTY LINE BY THE CONTRACTOR OR CUSTOMER MAKING THE CONNECTION, WITH A 2'x2'x4" CONCRETE PAD WITH A INVERTED PLUG, BOTH TO BE SET AT FINAL GRADE TYPICAL SEWER SERVICE CONNECTION NVERTED PLUG FLUSH W/ CONCRETE RAFFIC AREAS) GRADE 2' SO 3000 P 90" ELBOW (SEWER SWEEP) TYPICAL MAIN LINE TERMINAL CLEANOUT GRADE 2' SQUARE, 4" THICK 3000 P.S.I. CONC. PAD 6" CLEANOUT ASSEMBLY W/ SCREWED CAP— INVERTED PLUG FLUSH W/ CONCRETE PAD (NON —TRAFFIC AREAS) 6" P.V.C. WYE TO STREET SERVICE TO BUILDING TYPICAL SERVICE LATERAL ONE WAY CLEANOUT NOTES 1. ONE WAY CLEANOUT (SWEEP TO STREET SERVICE). 2. CLEAN OUT SHALL BE LOCATED ON RIGHT OF WAY LINE. 3. IN TRAFFIC AREAS A METAL CLEANOUT COVER AND LID SHALL BE INSTALLED OVER PVC CLEANOUT. 4. ALL CLEAN OUT'S REQUIRE AN INSPECTION. SECTION "A —A" NOTES 10/15 IDUA #31 MECHANICAL THRUST RESTRAINT CHART 1 PIPE 90° BEND 45° BEND 22 1 2° BEND 11 1 4° BEND DEADEND VALVE SIZE, in PVC DIP PVC DIP PVC DIP PVC DIP PVC DIP 4 21 16 9 7 5 4 2 2 45 29 6 28 23 12 10 6 5 3 3 63 40 8 37 29 16 12 8 6 4 3 83 53 10 44 35 18 15 9 7 5 4 99 63 12 51 41 21 17 11 8 5 4 116 74 14 57 46 24 19 12 10 6 5 132 83 16 64 51 27 21 13 11 7 5 149 94 18 70 56 29 24 14 12 7 6 164 104 20 76 61 32 26 16 13 8 6 179 113 24 87 70 36 29 18 14 9 7 208 131 THRUST RESTRAINT CHART BASED UPON THE FOLLOWING: PVC DIP PIPE MATERIAL, AS NOTED SP SOIL TYPE (designer to confirm) 1.5 SAFETY FACTOR (minimum) 3 TRENCH TYPE (designer to confirm) 2.5 DEPTH OF BURY, ft (designer to confirm) 150 TEST PRESSURE, psi (minimum) THE MINIMUM LENGTH OF PIPE OUT OF ANY VALVE OR FITTING SHOULD BE 20 LF. FITTINGS NOT SHOWN TO BE CALCULATED UTILIZING THE CRITERIA LISTED ABOVE AND SUBMITTED IN A SHOP DRAWING VALUES SHOWN IN CHART INDICATE LENGTH (LF) OF PIPE TO BE RESTRAINED ON EITHER SIDE OF ITEM LISTED NOTE 1:ANY CONDITION OTHER THAN THOSE LISTED ABOVE (including poly —wrapped DIP) SHALL REQUIRE REVISION OF THE TABLE IN ACCORDANCE WITH EBAA IRON, INC., RESTRAINT LENGTH CALCULATOR (V. 5.4). (http://www.ebaa.com/engineering.htm or http://rcp.ebac.com) NOTE 2:THE REVISED CHARTS SHALL BE SUBMITTED TO QUA AS A SHOP DRAWING SUBMITTAL. HEAVY WITH N MINIMUM ❑ ❑ ❑ ❑ SANI ARY SEWE R ❑ ❑ PLAN UTY C.I. FRAME AND COVER, N—PENETRATING PICK HOLES; WEIGHT 334 POUNDS; PAVED SURFACE FINISH GRADE UNPAVED SURFACE 2" TYP. I �22-3/4'� i� /ZZ7 21" 25-1 /4" 36" RAIN GUARD NOTES 1. A WATER —TIGHT MANHOLE "RAIN GUARD" INSERT SHALL BE INSTALLED IN ALL MANHOLES. 2. A 3'X3'X6" CONCRETE COLLAR SHALL BE INSTALLED WHERE MANHOLE IS INSTALLED IN UNPAVED AREAS 3. "SANITARY SEWER" FOR WASTEWATER APPLICATIONS. 4. "WATER" FOR WATER APPLICATIONS. WATER THRUST RESTRAINT 110/c5 IOcA #WI Eon STANDARD MANHOLE FRAME AND COVER I 1o/c5 I IFU #fl c5� 1. INVERT CHANNELS TO BE CONSTRUCTED FOR SMOOTH FLOW WITH NO OBSTRUCTIONS. 2. SPILLWAYS SHALL BE CONSTRUCTED BETWEEN PIPES WITH DIFFERENT INVERT ELEVATIONS PROVIDING FOR SMOOTH FLOWS. 3. CHANNELS FOR FUTURE CONSTRUCTION (STUBS) SHALL BE CONSTRUCTED, FILLED WITH SAND, AND COVERED WITH I" OF MORTAR. 4. SLOPE MANHOLE WITH A 1:2 SLOPE FROM MANHOLE WALL TO CHANNEL. 5. INVERT SHALL BE A MINIMUM OF 1/2 THE DIAMETER OF THE LARGEST PIPE OR 4" DEEP TYPICAL CLEANOUT I 1o/c5 o�AAfl„#F-c1 FLOW PATTERNS FOR MANHOLE INVERTS I 1o/c5 QUA #Afl Fob THIS DOCUMENT, TOGETHER WITH THE CONCEPTS AND DESIGNS PRESENTED HEREIN, AS AN INSTRUMENT OF SERVICE, IS INTENDED ONLY FOR THE SPECIFIC PURPOSE AND CLIENT FOR WHICH IT WAS PREPARED. REUSE OF AND IMPROPER RELIANCE ON THIS DOCUMENT WITHOUT WRITTEN AUTHORIZATION AND ADOPTION BY STEVEN L. DOBBS, P.E., SHALL BE WITHOUT LIABILITY TO NEWLINES ENGINEERING do SURVEY AND STEVEN L. DOBBS ENGINEERING, LLC. MINOR SUBDIVISION PLAN DETAILS — 4 GLENWOOD PARK LYING IN SEC 15, TOWNSHIP 37 SOUTH, RANGE 35 EAST, OKEECHOBEE CITY, FLORIDA ONEWLII�ES ANn CONS III I AIN I b LLC cc STEVEN L. DOBBS, P.E. PROJECT NO. FL22024 DRAWN BY J M SCALE AS SHOWN DATE 2022-1 1-17 FLORIDA CERTIFICATE OF AUTHORIZATION NO. 00029206 DATE STEVEN L. DOBBS ENGINEERING, LLC SHEET 1062 JAKES WAY OKEECHOBEE, FL 34974, PHONE (863) 824-7644 C603 OF 19 2. 3. 4. 5. 6. 7. PAVEMENT C.I. COVER (FOR PAVED AREA) CONCRETE VALVE PAD FINISHED GRADE (FOR NON —PAVED AREA) COMPACTED CAST IRON, ROADWAY TYPE, EARTH EXTENSION VALVE BOX 3" PVC W/THREADED PVC (INSIDE SCREW) INVERTED KEY PLUG (FLUSH) TWO (2) PAIRS OF INSULATED METALLIC 10 GAUGE SOLID COPPER WIRE (TYP.) EACH PAIR HEADING ON OPPOSITE DIRECTIONS PRESSURE MAIN DUCT TAPE (5 PER PIPE LENGTH) ALL PVC PIPE SHALL REQUIRE TWO PAIRS OF INSULATED METALLIC LOCATING WIRES (10 GAUGE SOLID COPPER) TAPED WITH 2" WIDE DUCT TAPE TO TOP CENTERLINE OF THE PIPE AT EVERY JOINT AND AT 4 ADDITIONAL EQUALLY SPACED POINTS PER LENGTH OF PIPE. LOCATING WIRES TO TERMINATE ON EACH END AT A VALVE BOX, 4" ABOVE GROUND AND FOLDED BACK INSIDE VALVE BOX. LOCATING WIRES SHALL BE CAPABLE OF DETECTION BY A CABLE LOCATOR AND PASS A FIELD CONDUCTIVITY TEST, OBSERVED BY THE O.U.A., FROM END TO END OF WIRES. SPLICES SHALL BE CAPABLE OF COMPLETE SUBMERSION, SUCH AS BUTT SPLICE WITH RAYCHEM HEAT SHRINK TUBING. NO MORE THAN ONE SPLICE IN LOCATING WIRES BETWEEN VALVES IS ALLOWED. PROVIDE POTTING COMPOUND AT TRACER WIRE JUNCTIONS AND SPLICES. THE ENDS OF ALL LOCATING WIRES, WHETHER THEY ARE SPLICED, CONNECTED, OR TERMINATED, SHALL HAVE THE LAST THREE INCHES PIG TAILED AS DETAILED HEREON. 4" WARNING TAPE METALLIC LOCATING WIRE + FINISHED GRADE 18" (MAXIMUM) 1" MAX PVC PRESSURE MAIN PVC PIPE LOCATING WIRE PIG TAIL WIRE AFTER PASSING THROUGH #10 THW LOCATING SPLIT BOLT WIRE (SOLID COPPER 4" MIN. WIRE WITH BLUE COATING) j— — �`2') y 4' MIN. 1 /4" X 3/4" SPLIT BOLT LOCATING WIRE DETAIL LOCATION WIRE DETAILS FOR ALL ROAD CROSSINGS AND BORES 10/15 �oUA #17I PLUG W/2" HOLE AND SS PLUG PLAN NOTES: 1. TERMINAL END SHALL BE MECHANICALLY RESTRAINED IN ACCORDANCE WITH QUA STANDARD DETAILS. THE NUMBER OF PIPE LENGTHS TO BE RESTRAINED SHALL BE IN ACCORDANCE WITH THE RESTRAINED JOINT TABLES. 2. SEE D9 FOR BLOW —OFF DETAILS. 1 1^0/15 QUA I #I151 TERMINAL END DETAIL THIS DOCUMENT, TOGETHER WITH THE CONCEPTS AND DESIGNS PRESENTED HEREIN, AS AN INSTRUMENT OF SERVICE, IS INTENDED ONLY FOR THE SPECIFIC PURPOSE AND CLIENT FOR WHICH IT WAS PREPARED. REUSE OF AND IMPROPER RELIANCE ON THIS DOCUMENT WITHOUT WRITTEN AUTHORIZATION AND ADOPTION BY STEVEN L. DOBBS, P.E., SHALL BE WITHOUT LIABILITY TO NEWLINES ENGINEERING do SURVEY AND STEVEN L. DOBBS ENGINEERING, LLC. MINOR SUBDIVISION PLAN DETAILS - 5 GLENWOOD PARK LYING IN SEC 15, TOWNSHIP 37 SOUTH, RANGE 35 EAST, OKEECHOBEE CITY, FLORIDA �ONEWLII�ES,,,cc STEVEN L. DOBBS, P.E. FLORIDA CERTIFICATE OF AUTHORIZATION NO. 00029206 STEVEN L. DOBBS ENGINEERING, LLC 1062 JAKES WAY OKEECHOBEE, FL 34974, PHONE ( DATE 63) 824-7 FL22024 BY J M AS SHOWN 2022-1 1-17 C604 OF 19 N: 1059354.54 E.• 711816.79 ELEV. 28.22' A27 8' 7.4' ?74276' '23' �274' s 0 - -27.8' 0 v ° v x27.6' X 26.20 7' v ° v X,27.60 . - ° X'27.55 s +27. IDENTIFICATION I 0 OAK v � • X 26.30 0 2500 v � B� I oI 1 U w +26.6' 00 O° 0 0 0 'D28.00 28.00 24 " OA 26.0' x26.9 NE 5TH STREET .27.4-' 25.50-X X 25.30 da189'43'41 "EX252699.6 o 27.5 - - 27.50 K X 26.20 (`r:'� I ° `tom.--'' 277' x277' 27 6' +23.9' 27.7' c277.8' I 2 �++' 11 �27. _ _ _ _ _ _ _ _ A D 70 OA Z W 6 OAK ' D 112" IRON ROD & CAP Q BSM LB 8155 Z X 26.00 " 00 28.00 28. N \` W ►I I Z 27 5' \\,27.5' 4' 1277' 127.3' 7.3' 9' 1272' L X 26.0' s 26.2' c26.0' 26.1' 26.0' v d 25.9' ■26. 1' X 24.70 M ° 26.0' c26.1 ' o ° ICHMARK f40002 ND NAIL & DISC IMPING ILLEGIBLE N: 1058969.50 E. 711817.98 MATCHLINE SHEET C301 ELEV.= 26,34' MATCHLINE SEE SHEET C302 4�MAN0 6' 0 +24.3' 14 " w OAK " PINE Ali PALM 4 " bA K OAK AK „I_... 72"" OAK 078" PINL016'+ PALM M 12 OAK 032" t O O ll a ° X 26.83 , , v ° X 24.10 4 ' OAK 6" OAK F'- 23.40-X +23.2' 1011OAK o SIN 47'50"W 27,K77 X 24.30 x?5.0" '° X _iA -_- 4 '1 OAK 18 Ci INV. ELEV. - 23.- FND 518" IRON R� o •> '. UN v � s X24. OAK ` l K 8 0/1 E 4" / \ 7 AK 2' A I " O K 4' OAK 2" OAK I 4' OAK 23.5' ooda. KOAK 72 0 1 6" OAK 6' OAK 20" OA I AM- \N + " OAK " OAK 0" OAK " OAJ I I 16" PIN 012" 0 K +24.2' +24.2' 6" OAK 0" OAK 020" 0 K Ql� v 1 OAK 22 ' K O O K 4 OAK I PALM Itv " OAK A= 014" OAK 0 " OAK I 4 " OAK 12„ 4) TREE 1 27.0 00 I +24.1' FND 112" STAMP BSM LB • 14" PALM 4 OAK 36" OAK x23.4' X 23 30 NO IDENTIF, E. 2 86. LEGEND ELEV. = 26. e PROPOSED PALM TREE (14 PROVIDED) b 18" CMP 26.2' - e INV. ELEV. = 23.25' 6.1' 26.o PROPOSED TREE (11 PROVIDED) ° '25. 23.30 8D 8D 3D SD-SD- ,X26.2 26.1PROPOSED SHRUB (184 PROVIDED) 5, 25.8' ­ 2 , ' EXISTING PALM TREE TO REMAIN (7 TOTAL) - 2 23.8' v P/ E °, b gEXISTING TREE TO REMAIN (67 TOTAL) �24.20 27.00 I EXISTING PINE TREE TO REMAIN (8 TOTAL) I \ NOTE 8 1. THERE ARE EXISTING TREES ONSITE THAT WILL MEET SOME OF THE LANDSCAPING REQUIREMENT. SINCE THERE IS NOT A TREE SURVEY, THIS WILL BE FIELD ADJUSTED. 25.2' 25.8' 25.7' 2. THIS PLAN FOR SITE APPROVAL AND ONLY INDICATES THE LOCATION AND TYPE OF PROPOSED W LANDSCAPING. THE SELECTED PLANT TO BE INSTALLED WILL HAVE TO MEET THE CITY OF 24 23. OKEECHOBEE'S DIVISION 4 LANDSCAPE CODE FOR TYPE AND SIZE OF PLANTS INSTALLED. Z 3. THE NORTH PARCEL HAS ALREADY BEEN THROUGH SITE PLAN AND WAS PREVIOUSLY 27.00 I W APPROVED AND CERTIFIED PRIOR TO CERTIFICATE OF OCCUPANCY FOR THE LATEST CITY OF G° I 24.40 /> OKEECHOBEE TRC APPROVAL. b 4. CONSIDERATION WILL BE MADE TO PROTECT THE OVERHEAD UTILITY LINES FROM MATURE w TREE GROWTH. i� I LL IbI M 5. PLANTINGS WILL BE ELECTED FROM SOUTH FLORIDA WATER MANAGEMENT DISTRICT'S b I W XERISCAPE PLAN GUIDE, WITH AT LEAST 75% OF THE TOTAL REQUIRED PLANS BEING NATIVE o VERY DROUGHT TOLERANT SPECIES AS LISTED IN THAT PLANT GUIDE. �26.20 Z 6. TREES SHALL BE AT LEAST 10' HIGH AND 2" DIAMETER MEASURED 4' ABOVE GROUND LEVEL Nd 1/2" I ON R D & CAP AT THE TIME OF PLANTING. TA PED SM LB 8155" 7. LANDSCAPE AREAS WILL BE MULCH AROUND TREES AND SHRUBS. 8. FOR A DIVERSITY OF PLANTINGS, CABBAGE PALM (CAULIS PALMA) AND PINDO PALM (PINDO k7.O PALMA) WILL BE USE IN PLACES OTHER THAN DESCRIBE BELOW: FOR TREES UNDER POWER LINES, DAHOON HOLLY (DAHOON ILEX), SILVER BUTTONWOOD 24.60 (ARGENTUM BUTTONWOOD), AND CRAPE MYRTLE (CRAPE MYTUS) WILL BE USED. b. FOR SHADE IN THE PARKING AREAS, LIVE OAK (VIVAMUS QUERCUS), BLACK OLIVE (OLIVAE NIGRAE) OR GREEN BUTTONWOOD (GREEN BUTTONWOOD) WILL BE USED. ' 124. 25.5' 26.0' 25.8' b � !7.00 ° I 24 80 b I FND 112"ION ROD STA PED "ESM LB 87. v 4. • v -*26.20 25.( - X 5. 24. S 0 �v w f 25.00 `27.00 � 25.8' o +2 0 U/ +25.8 27.00 • X 24 v° -26. 1'�25.8' 1 P f25.66 ° v C v s NV V.= 2 s .52 26.0' x25.2 X2 X25.4' 25.8' ■26.0' 25.7' x24. 1' X24.0' 9D 8D 8D )C22.90 - 23. X 22.50-s °v, 25.5' 25.8' = 23. 6' 78" RCP S INV. ELEV. = 78. 6 o I _ R' 5.8' NE 4TH STREET q GRAPHIC SCALE 20 0 10 20 40 80 SCALE: 1:250 LANDSCAPING REQUIREMENTS TREES SHRUBS 1 TREE AND 3 SHRUBS FOR EVERY 3,000 SF OF LOT AREA - 87,120 SF 30 90 AT LEAST 1 TREE AND 3 SHRUBS FOR EACH 300 SF OF REQUIRED LANDSCAPED BUFFER 270 LF OF NON -DRIVEWAY FRONTAGE ON NE 5TH ST FOR 10' BUFFER REQUIRES 2,700 SF OF LANDSCAPED AREA 9 27 220 LF OF NON -DRIVEWAY FRONTAGE ON NE 3RD AVE FOR 10' BUFFER REQUIRES 2,200 SF OF LANDSCAPED AREA 7 22 270 LF OF NON -DRIVEWAY FRONTAGE ON NE 4TH FOR 10' BUFFER REQUIRES 2,700 SF OF LANDSCAPED AREA 9 27 300 LF OF FRONTAGE ON NE 2ND AVE FOR 10' BUFFER REQUIRES 3,000 SF OF LANDSCAPE AREA 10 30 18 SF OF LANDSCAPING FOR EVERY PARKING SPACE - 1 TREE AND 3 SHRUBS FOR EVERY 72 SF OF LANDSCAPING - 50 15 45 PROPOSED PARKING SPACES LANDSCAPE ISLANDS MIN 5' X 150 EVERY 10 SPACES MA. UNINTERRUPTED SPACES 12 MULTIFAMILY TWO TO FOUR BEDROOMS (3 TREES PER UNIT) - 22 UNITS 70 210 MULTIFAMILY ONE BEDROOM (2 TREES PER UNIT) 0 0 TOTAL: 70 210 NOTES: LANDSCAPING REQUIREMENT WILL REQUIRE MINIMUM LANDSCAPING BASED ON MULTIFAMILY UNITS OF MORE THAN 2 BEDROOMS OF 70 TREES AND 210 SHRUBS. ( IN FEET ) 1 inch = 20 ft. MATCHLINE SEE SHEET C301 MATCHLINE SHEET C302 - 8D 8D 8D —2 ' . 7' 26.7' 126.7' ❑ #273' 27.2' ago NE 4TH STREET NE 3RD STREET NE 4TH STREET GRAPHIC SCALE 20 0 10 20 40 7' `INV. ELEV. = 25.44' 25.6 11I LEGEND PROPOSED PALM TREE (27 PROVIDED) PROPOSED TREE (14 PROVIDED) PROPOSED SHRUB (176 PROVIDED) EXISTING PALM TREE TO REMAIN (2 TOTAL) C EXISTING TREE TO REMAIN (15 TOTAL) I / EXISTING PINE TREE TO REMAIN (1 TOTAL) NOTE 1. THERE ARE EXISTING TREES ONSITE THAT WILL MEET SOME OF THE LANDSCAPING REQUIREMENT. SINCE THERE IS NOT A TREE SURVEY, THIS WILL BE FIELD ADJUSTED. 2. THIS PLAN FOR SITE APPROVAL AND ONLY INDICATES THE LOCATION AND TYPE OF PROPOSED LANDSCAPING. THE SELECTED PLANT TO BE INSTALLED WILL HAVE TO MEET THE CITY OF OKEECHOBEE'S DIVISION 4 LANDSCAPE CODE FOR TYPE AND SIZE OF PLANTS INSTALLED. 3. THE NORTH PARCEL HAS ALREADY BEEN THROUGH SITE PLAN AND WAS PREVIOUSLY APPROVED AND CERTIFIED PRIOR TO CERTIFICATE OF OCCUPANCY FOR THE LATEST CITY OF OKEECHOBEE TRC APPROVAL. 4. CONSIDERATION WILL BE MADE TO PROTECT THE OVERHEAD UTILITY LINES FROM MATURE TREE GROWTH. 5. PLANTINGS WILL BE ELECTED FROM SOUTH FLORIDA WATER MANAGEMENT DISTRICT'S XERISCAPE PLAN GUIDE, WITH AT LEAST 75% OF THE TOTAL REQUIRED PLANS BEING NATIVE VERY DROUGHT TOLERANT SPECIES AS LISTED IN THAT PLANT GUIDE. 6. TREES SHALL BE AT LEAST 10' HIGH AND 2" DIAMETER MEASURED 4' ABOVE GROUND LEVEL AT THE TIME OF PLANTING. 7. LANDSCAPE AREAS WILL BE MULCH AROUND TREES AND SHRUBS. 8. FOR A DIVERSITY OF PLANTINGS, CABBAGE PALM (CAULIS PALMA) AND PINDO PALM (PINDO PALMA) WILL BE USE IN PLACES OTHER THAN DESCRIBE BELOW: a. FOR TREES UNDER POWER LINES, DAHOON HOLLY (DAHOON ILEX), SILVER BUTTONWOOD (ARGENTUM BUTTONWOOD), AND CRAPE MYRTLE (CRAPE MYTUS) WILL BE USED. b. FOR SHADE IN THE PARKING AREAS, LIVE OAK (VIVAMUS QUERCUS), BLACK OLIVE (OLIVAE NIGRAE) OR GREEN BUTTONWOOD (GREEN BUTTONWOOD) WILL BE USED. KEY MAP SCALE: 1:250 LANDSCAPING REQUIREMENTS TREES SHRUBS 1 TREE AND 3 SHRUBS FOR EVERY 3,000 SF OF LOT AREA — 87,120 SF 35 105 AT LEAST 1 TREE AND 3 SHRUBS FOR EACH 300 SF OF REQUIRED LANDSCAPED BUFFER 270 LF OF NON —DRIVEWAY FRONTAGE ON NE 5TH ST FOR 10' BUFFER REQUIRES 2,700 SF OF LANDSCAPED AREA 9 27 220 LF OF NON —DRIVEWAY FRONTAGE ON NE 3RD AVE FOR 10' BUFFER REQUIRES 2,200 SF OF LANDSCAPED AREA 10 30 270 LF OF NON —DRIVEWAY FRONTAGE ON NE 4TH FOR 10' BUFFER REQUIRES 2,700 SF OF LANDSCAPED AREA 9 27 300 LF OF FRONTAGE ON NE 2ND AVE FOR 10' BUFFER REQUIRES 3,000 SF OF LANDSCAPE AREA 7 22 18 SF OF LANDSCAPING FOR EVERY PARKING SPACE — 1 TREE AND 3 SHRUBS FOR EVERY 72 SF OF LANDSCAPING — 50 15 45 PROPOSED PARKING SPACES LANDSCAPE ISLANDS MIN 5' X 150 EVERY 10 SPACES MA. UNINTERRUPTED SPACES 12 MULTIFAMILY TWO TO FOUR BEDROOMS (3 TREES PER UNIT) — 70 210 22 UNITS MULTIFAMILY ONE BEDROOM (2 TREES PER UNIT) 0 0 TOTAL: 70 210 NOTES: LANDSCAPING REQUIREMENT WILL REQUIRE MINIMUM LANDSCAPING BASED ON MULTIFAMILY UNITS OF MORE THAN 2 BEDROOMS OF 70 TREES AND 210 SHRUBS. ( IN FEET ) 1 inch = 20 ft.