Loading...
2013-05-16 +'''' MINUTES OF THE 'o ° TECHNICAL REVIEW COMMITTEE 4 THURSDAY, MAY 16, 2013, 10:00 A.M. ,r , CITY OF OKEECHOBEE 4247.0o- 55 Southeast 3rd Avenue Okeechobee, Florida 34974 Page 1 of 3 I. CALL TO ORDER—Chairperson. The meeting was called to order at 10:00 a.m. by Chairperson Whitehall. II. STAFF ATTENDANCE—Secretary. City Administrator Brian Whitehall-Present Building Official Jeffrey Newell -Present Police Chief Denny Davis-Present Fire Chief Herb Smith -Present Public Works Director David Allen-Present City Engineer-Position is vacant at this time Non-Voting Ex-Officio Members: City Attorney John R. Cook- Present(arrived at 10:07 a.m.) City Planning Consultant Bill Brisson-Present OUA Executive Director John Hayford-Present County Environmental Health Department Representative- Present School District Representative-Absent Board Secretary Patty Burnette-Present III. MINUTES—Secretary. A. Police Chief Davis moved to dispense with the reading and approve the February 21, 2013 Technical Review Committee regular meeting minutes; seconded by Fire Chief Smith. Motion carried unanimously. IV. NEW BUSINESS—Chairperson. A. CRCO Properties, LLC. 13-002-TRC. Application was submitted by Steven Dobbs, P.E., on behalf of the property owner, CRCO Properties, LLC, in regards to converting an existing 8,000 sq. ft. retail furniture store to a 5,000 sq. ft. fitness center, a 1,500 sq. ft. retail nutrition store and a 1,500 sq. ft. of warehouse space located at 704 North Parrott Avenue, Okeechobee, FL. and to include remote parking lot—Senior Planner. City Planning Consultant Brisson explained to the Board that the applicant is proposing to convert an existing commercial building as stated above. The legal description is Lots 18 to 20 of Block 57, City of Okeechobee. Plans were originally reviewed and found the project did not provide the adequate required parking, and included parking along the right-of-way on Northeast 7th Street. The City's Land Development Regulations do not allow private,off-street parking to be located in the public right-of-way. TRC-May 16,2013-Page 2 of 3 IV. NEW BUSINESS CONTINUED. A. CRCO Properties, LLC. 13-002-TRC continued. In an effort to address the 10 additional parking spaces required, but cannot be constructed on the subject property, the applicant is requesting to utilize a remote parking lot on additional property they own, located one block south (behind Big Lake Eye Care). Discussion then turned to pedestrian safety, and concerns that customers would park illegally along the right-of-way, regardless of the remote parking area. Then the fact that customers would be crossing another owner's property, located at 610 North Parrott Avenue was a concern. Should the remote parking be approved, Planner Brisson suggested"No Parking"signs be erected along 7th Street and rigorously enforced and the two property owners enter into a written agreement, giving consent for the customers to traverse across each other's property. The agreement would need to be reviewed for legal sufficiency by Attorney Cook prior to execution. A proposed agreement was then distributed, should it be deemed legally acceptable by Attorney Cook, this would adequately address the safety concerns. For the record, and to clarify, Administrator Whitehall, confirmed with the Board that parking on the right-of- way was not up for discussion as this was not the prerogative of the TRC to propose to the City Council, However, should the City Council decide to address it as a means to approve a parking reduction, they could.All Board members were in agreement. Engineer Steven Dobbs, addressed the Board by first stating that he did not have an updated site plan to provide at this time, as he was trying to satisfy all the parking requirements before having the applicant expend additional costs on the project, once approval is obtained for the remote parking, revised proposed construction plans would be submitted. Following a lengthy discussion, the consensus of the TRC was to recommend the applicant seek approval from the City Council for the off-street parking arrangement (remote parking), then return for the Board to address the construction conditions and details. A full site plan would be required showing 40 parking spaces, based on the City Council's decision, as well as addressing a solid waste dumpster location and loading zone on the subject property. Comments from the Departments: County Environmental Health Department: Mr. McCoy commented the current septic system was constructed and designed for two bathrooms. Should the applicant propose installing showers or using a Jacuzzi, the system would most likely need to be upgraded. The applicant responded he was proposing to abandon the current septic system and install a lift station. OUA: Mr. Hayford's comments reflected there is a fire hydrant on the site, and a force main is located one- half a block to the south within the alleyway. He confirmed the property is utilizing septic, not sewer. Finally, should the applicant propose each of the three types of businesses have individual addresses, the meter will need to be changed to one for each business address. Building Official: Mr. Newell's main concern was with a change of ownership and whether the remote parking lot would be tied to the subject property, and how it could continue legally, should the applicant decide to sell either property. Public Works: Mr. Allen was concerned with parking as well and providing a safe route for pedestrians crossing Northeast 7th Street. Police Department: Chief Davis noted his concerns with potential illegal parking on the right-of-way and that his department would be enforcing the no parking along 7th Street. He further gave an example of another fitness center with a parking agreement and the patrons continue to park illegally on the right-of-way. TRC-May 16,2013-Page 3 of 3 IV. NEW BUSINESS CONTINUED. A. CRCO Properties, LLC. 13-002-TRC continued. Fire Department: No issues were received. Fire Chief Smith moved to recommend to the City Council to approve the concept of the remote parking lot with the condition that the construction details and compliance issues be addressed by the Technical Review Board regarding Application No. 13-002-TRC; seconded by Public Works Director Allen.Motion carried unanimously. V. ADJOURNMENT—Chairperson. There being no further items on the agenda, Chairperson Whitehall adjourned the Technical Review Committee meeting at 11:02 a.m. PLEASE TAKE NOTICE AND BE ADVISED that any person desiring to appeal any decision made by the Technical Review Committee with respect to any matter considered at this proceeding, such interested person will need a record of the proceedings, and for such purpose may need to ensure a verbatim record of the proceedings is made, which record includes the testimony and evidence upon which the appeal is to be based. General Service's media are for the sole purpose of backup for official records of the Department. / ATTEST: lir „4„ Ruth, i,-,1_ . 21LQ Brian Whit j , Chairpers• Patty M. Burnette, Secretary CITY OF OKEECHOBEE MAY 16, 2013 TECHNICAL REVIEW COMMITTEE HANDWRITTEN MINUTES 1. CALL TO ORDER - Chairperson: May 16, 2013 Technical Review Committee Meeting, 10:00 a.m. II. STAFF ATTENDANCE - Secretary Present Absent Administrator Whitehall Building Official Newell Chief Davis Chief Smith Engineer Public Works Director Allen i/ NAY ✓ ABSENT ✓ I/ Position vacant at this time ✓ Non - Voting Ex- Officio Member: Attorney Cook County Health Department McCoy OUA Executive Director Hayford Senior Planner Brisson School Representative Secretary Burnette � �� D' o l k/ r/ Smith III. MINUTES - Secretary. A. Motion to dispense with the reading and approve the Summary of Technical Review Committee Minutes for the February 21, 2013 regular meeting. V d moved to dispense with the reading and approve the Summary of Technical Review Committee Minutes for the February 21, 2013 regular meeting; seconded by -Vv . VOTE YEA NAY ABSTAIN ABSENT Allen Davis Newell Smith iteha APPROVED DENIED IV. NEW BUSINESS - Chairperson. IC. l2 �ti A. CRCO Properties, LLC. 13- 002 -TRC. Application was submitted by Steven Dobbs, P.E., on behalf of the property owner, CRCO Properties, LLC, in regards to converting an existing 8,000 sq. ft. retail furniture store to a 5,000 sq. ft. fitness center, 1,500 sq. ft. retail nutrition store and 1,500 sq. ft. of warehouse space located at 704 North Parrott Avenue, Okeechobee, FL. and to include remote parking lot — Senior Planner. Discussion: •7rib5O t A vatvecl CLvc td Pa+wc,4A-4, pate/GA-al aetuatl1 100--i teed �1 ((AAA( �1=vu `i'i~e_ r ice 4e `i ?i plc(. kuji ries� ky lje t 'do u f no pQ,vittn:cj (LC) is / fJ -Qopk W l pctf r_ r1- s.- u.rd 1,.; I ni pk,04 t � 5 pu co-s bus ss n ci x-a- • -- spats r L u vK p s ) 0ca. fi c u VULt cLtd D� (YD ( 1 5 t4 e LCAA. C cod 4 01c- ' , fe��� , - P'1"7" 0 (�c ° ,tea ,' (61t� itl' {�-t1t � t ���s�e�l t �, d pi IL Motion: moved to approve/deny site plan review submitted by Steven Dobbs, P.E., on behalf of the property owner, CRCO Properties, LLC, in regards to converting an existing 8,000 sq. ft. retail furniture store to a 5,000 K�sq. ft. fitness center, 1,500 sq. ft. retail nutrition store and 1,500 sq. ft. of warehouse space located at 704 North Parrott �>� Avenue, Okeechobee, FL. and to include remote parking lot; seconded by . Contingencies: Y r)- cy VOTE Yr\A NAY ABSTAIN ABSENT Allen Davis Newell S' hit APPROY ' DENIED V. ADJOURNMENT - Chairperson. There being no further items on the agenda, Chairperson adjourned the Technical Review Committee Meeting at a.m. 2 • Ne bolo(, ei LiD^ ‘b✓ d+}e.s DWI test. Wu. u;) ptifvva-4- -faNr Gu t v/ t n JA./-c-k, ` ru -l- 30-r - Q ss -l'u c.u,i vet igdmin �� vr: PcIA1,vti ustv R03 — !1m QLt (h ��-- I�° 41. • 4 drux,sy o.co i5 i+ -h e d }v wo..t_ )=f' acv ( t:71- i- (KD -3koateL Dv, P)u,✓ -i-ds daci- h,a c crn. c-e..vvts POt pvvkc - penes l u t : i A 4 th ( ay124h 1- 1.-) G r/11- `14,1. it- aloin 5ar r)l4k- {bath. c011/1144. 4', rn..w Cc- ( 5 Wit-- 41tAs (no a' w3 Pe op le 0,1_,L tati e S� -_7) h7Laii 'C QUA f�l - 1� 2ct� f -6�GLu : ✓4 0 (-aCC 1--t �l pct_rlce.d 0 n "o) pre .CL no (A ct,b i U 11.4 4° CAA-Z.( CUBnl� railftvvi St -17“.3 ns Sick, e _ A itt,,A4,01 Cook no � 4 a CCoc� oo t Lo g e a bik,41^rou, 0 p 1lvd- w f Lt, a C.e_a -L1 v • brt-v- -e_ l s 1 a 3 ) z 4 n --&-L., ii i' 0 g Cecil . Let g- aJ C.49 . In ti ,..vh Nvle1.vt g9 -.-LIZ J-164( -6 4 DIM, 1 ? /34-714 zo —s-4■L 177 % - d 3 - / el 5Y 4-- / u� . ( _., pt.„ G C T4_ C._ /1: v Lc e CITY OF OKEECHOBEE TECHNICAL REVIEW COMMITTEE OFFICIAL AGENDA MAY 16, 2013 CITY HALL, COUNCIL CHAMBERS 55 SOUTHEAST 3" AVENUE OKEECHOBEE, FLORIDA 34974 I. CALL TO ORDER MAY 16, 2013, 10:00 a.m. - Chairperson. II. STAFF ATTENDANCE - Secretary. Voting Members: Non - Voting Ex- Officio Member: III. MINUTES - Secretary. Denny Davis, Police Chief David Allen, Public Works Director Jeffery Newell, Building Official Herb Smith, Fire Chief Brian Whitehall, Administrator Doug McCoy, Okeechobee County Health Department John Hayford, Okeechobee Utility Authority Bill Brisson, Senior Planner, LaRue Planning and Management John Cook, City Attorney School Representative Patty Burnette, Secretary A. Motion to dispense with the reading and approve the Summary of Technical Review Committee Minutes for the February 21, 2013 regular meeting. IV. NEW BUSINESS - Chairperson. A. CRCO Properties, LLC. 13- 002 -TRC. Application was submitted by Steven Dobbs, P.E., on behalf of the property owner, CRCO Properties, LLC, in regards to converting an existing 8,000 sq. ft. retail furniture store to a 5,000 sq. ft. fitness center, 1,500 sq. ft. retail nutrition store and 1,500 sq. ft. of warehouse space located at 704 North Parrott Avenue, Okeechobee, FL. and to include remote parking lot — Senior Planner. V. ADJOURNMENT TECHNICAL REVIEW COMMITTEE MEETING — Chairperson. PLEASE TAKE NOTICE AND BE ADVISED that if any person desires to appeal any decision made by the Technical Review Committee with respect to any matter considered at this proceeding, such interested person will need a record of the proceedings, and for such purpose may need to ensure a verbatim record of the proceedings is made, which record includes the testimony and evidence upon which the appeal is to be based. Media is the sole purpose of backup for official records of the Department. INDEPENDENT NEWSPAPERS OKEECHOBEE NEWS NEWSPAPERS OKEECHOBEE NEWS J J STATE OF FLORIDA COUNTY OF OKEECHOBEE 107 S.W. 107 S. 17th Street, Suite D, Okeechobee, FL 34974 Before the undersigned authority personally appeared Tom Byrd, who on oath says he is Publisher of the Okeechobee News, a three times a week Newspaper published at Okeechobee, in Okeechobee County, Florida, that the attached copy of advertisement being a in the matter of in the 19th Judicial District of the Circuit Court of Okeechobee County, Florida, was published in said newspaper in the issues of Affiant further says that the said Okeechobee News is a newspaper published at Okeechobee, in said Okeechobee County, Florida, and that said newspaper has heretofore been published continuously in said Okeechobee County, Florida each week and has been entered as second class mail matter at the post office in Okeechobee, in said Okeechobee County, Florida, for a period of one year next preceding the first publication of the attached copy of advertisement, and affiant fur- ther says that she has neither paid nor promised any person, firm or corporation any discount, rebate, com- mission or refund for the purpose of securing this advertisement tor publication in the said newspaper. Toni Byrd Sworn to and subscribed before me this day of ? am. rA (. . ) AD Notary Public, State of Florida at Large ANGIE BRIDGES • ; ±, :*6 MY COMMISSION # EE 177653 EXPIRES: April 20, 2016 <PV Bonded Thor Notary Public Underwriters (863) 763 -3134 5 -I -13 ff `i ] Lt TECHNICAL REVIEW COMMITTEE MEETING NOTICE NOTICE IS HEREBY GIVEN that the Technical Review Committee of the City of Okeechobee will meet in Regular Session on Thursday May 16, 2013, at 10:00 a.m., City Hall, 55 SE 3rd Ave, Rm 200, Okeechobee, Florida. The public is invited and encouraged to attend. Contact Patty Bur - nette at 863 - 763 -3372, or website www,chvofokeechobee.com, to obtain a copy of the agenda. PLEASE TAKE NOTICE AND BE ADVISED that no stenographic record by a certified 'court reporter will be made of the foregoing meeting. Accordingly, any person who may seek to appeal any decision involving the matters no- ticed herein will be responoble for making a verbatim record of the testimo- ny and evidence at said meeting upon which any appeal is to be based. In accordance with the Americans with Disabilities Act (ADA) of 0990 per- sons needing special accommodation to participate in this proceeding should contact the General Services Office, at863- 763 -3372 for assistance. by: Brian Whitehall, City Administrator 443062 ON 5/10/2013 Patty Burnette From: Patty Burnette <pburnette @cityofokeechobee.com> Sent: Tuesday, June 04, 2013 2:47 PM To: sdobbs @stevedobbsengineering.com Subject: TRC Mtg 5/16/13 Attachments: TRC 051613 Minutes.pdf Hi Steve. I have attached a copy of the TRC Minutes from the May 16th meeting. I understand you have submitted an Agenda Request Form to be on the City Council Agenda for the June 18th meeting. This meeting will be in the Council Chambers at 6:00 p.m. The Council packets will consist of a copy of these minutes, your Agenda Request Form, the Site Plan you submitted and a Copy of the Planner's Staff Report. Should you have any questions, please just let me know. Thank you, Patty Patty mil. Burnette Cgenera(Services Coorcdina.tor City of Okeechobee 55 Southeast 3rd Avenue Okeechobee, 'FL 34974 T'er 863- 763 -3372 ext. 218 'Fax: 863 -763 -1686 e-mail? ibli1'ilcttt'iA_Irvolokcc iIA L't'.ct'l1? website: Itt?of o tilll NOTICE: Due to Florida's broad public record laws, this email may be subject to public disclosure. Staff Report Site Plan Review Prepared for: The City of Okeechobee Applicant: CRCO Properties, LLC (Fitness Ctr., Nutrition Store) Petition No.: 13- 002 -TRC (Revised to include remote parking lot) t ?i�'_..l Planning & Management Services, Inc. 75 Jackson Street, Suite 206 Fort Myers, Honda 239-M4-3366 Serving Florida Local Governments Since 1988 Staff Report Site Plan Review Applicant: CRCO Properties, LLC Petition No.: 13- 002 -TRC General Information Owner: Owner Address: Applicant: Applicant Address: Site Address: Contact Person: Applicant/Contact Phone Number: CRCO Properties, LLC NW 115th Street Okeechobee, FL 34972 CRCO Properties, LLC 364 NW 115th Street Okeechobee, FL 34972 704 North Parrott Avenue Okeechobee, FL 34972 Steven L. Dobbs, P.E., Engineer 863 - 824 -7644 Legal Description of Subject Property: LOTS 18, 19, AND 20, BLOCK 57, OKEECHOBEE, ACCORDING TO THE PLAT THEREOF RECORDED IN PLAT BOOK 5, PAGE 5, PUBLIC RECORDS OF OKEECHOBEE COUNTY, FLORIDA. General Description: The Applicant is converting an existing 8,000 square foot retail furniture store to a 5,000 square foot fitness center, 1,500 square foot retail nutrition store and 1,500 square feet of warehouse space. All functions will take place inside the building with 3 — 5 employees and the hours of operation will be from 6:00 AM until 8:00 PM. The Applicant is proposing to provide parking at a remote lot behind the Big Lake Eye Care building, as provided for under Sec. 90- 511(a)(2). Following is the Staff analysis of the project's consistency with the various City requirements and regulations. Instances where the Staff believes the submission to be deficient are highlighted. Future Land Use Map Classification Zoning District Use of Property Existing Commercial CHV Former furniture store 20,909 sq ft (0.48 acres) Serving Florida Local Governments Since 1988 Proposed Commercial CHV Fitness center & nutrition store with warehouse space 20,909 sq ft (0.48 acres) Staff Report Site Plan Review Applicant: CRCO Properties, LLC Petition No.: 13- 002 -TRC Adjacent FLUM Classifications, Zoning Districts, and Existing Land Use: North: Future Land Use Map Classification: Zoning District: Existing Land Use: East Future Land Use Map Classification: Zoning District: Existing Land Use: South Future Land Use Map Classification: Zoning District: Existing Land Use: West: Future Land Use Map Classification: Zoning District: Existing Land Use: Commercial CHV Quick Change oil & lube service Commercial CHV Mini - storage & towing service Commercial CHV Offices Commercial CHV Building & open storage Adequacy of Public Facilities: Potable Water and Sanitary Sewer: Since the demand for potable water and sewer service associated with a 5,000 square foot fitness center and other uses proposed for the existing building will significantly exceed that which would normally be associated with a furniture store, the Applicant should obtain a letter from the Okeechobee Utility Authority (OUA) stating that it has adequate capacity to serve the proposed use. Solid Waste Disposal: On a number of occasions the County has confirmed a consi- derable level of excess capacity available to serve the solid waste disposal needs of other developments in the City. It appears reasonable that the volume of solid waste associated with a development of this size can also be accommodated within the capacity of the County's Solid Waste Facility. Traffic: According to the 7th Edition, ITE Trip Generation Manual, the proposed mix of uses is likely to generate about 28 vehicle trips during the weekday PM peak hour. While this is considerably more than the most recent use as a furniture store (which only generated slightly less than four trips), it is not significant with respect to the available capacity of the adjacent roadways. ti Serving Florida Local Governments Since 1988 2 Staff Report Site Plan Review Applicant: CRCO Properties, LLC Petition No.: 13- 002 -TRC Drainage: In the event of any increase in the amount of impervious surface on the site will require that the Applicant meet all standards required by the City of Okeechobee and the South Florida Water Management District. Comparison of Proposal with Dimensional Standards, CHV Zoning: Regulation Required Provided Minimum Parcel Size 6,250 square feet; 50' width 20,909 square feet; 147' width Minimum Front Yard Setback 20 feet for buildings, 10 feet for parking 50+ feet for building. Minimum Side Yard Setback 8 feet 23 feet on the east and west sides Minimum Rear Yard Setback 10 feet Existing rear setback is nonconforming at about nine feet. Maximum Lot Coverage 50% 38.6% Maximum Lot Coverage and Other Impervious Surfaces 85% 80.8% (est.) Off- street Parking one space per 150 sf of fitness center (5000/150) = 33.3; one space per 1,000 sf of warehouse (1500/1000) = 1.5; one space per 300 sf of retail (1,500/300) = 5; total required = 40 spaces There are now ten (10) parking spaces located in front of the building. More discussion is provided on the following page. Serving Florida Local Governments Since 1988 3 Staff Report Site Plan Review Applicant: CRCO Properties, LLC Petition No.: 13- 002 -TRC DISCUSSION REGARDING USE OF REMOTE PARKING BEHIND BIG LAKE EYE CARE The Applicant has suggested using the unimproved area behind Big Lake Eye Care, a property also owned by the Applicant to augment the ten spaces presently located on the subject site. Staff has visited the site and nearby properties and explored the viability of using this property as a remote parking lot to serve the proposed use under the provisions of §90- 511(a)(2). This visit indicated that the only likely pedestrian route to be utilized by patrons of the proposed use(s) to go to and from the proposed off -site parking area would be crossing NE 7th Street into and through the parking lot behind the property located at 610 N. Parrott Avenue. The Applicant has submitted a preliminary drawing of the proposed remote parking lot. This drawing indicates to us that the walking distance between the front door of the subject property and the nearest parking space in the remote lot will be about 370 feet. At a common pace of 3 to 3.5 mph, it would take one about somewhat under 1 1/2 minutes to go from the closest parking space to the door of the fitness center. If one is at the most remote parking space, the walking distance would be about 600 feet and would take between 2 and 2.3 minutes. Having traversed this route a couple of times during my site visit, I did not find it inconvenient. I did not walk the longer route to the most remote space at that time. Even though the distance between the remote parking lot and the fitness center may be acceptable, parking will most likely occur along the right -of -way on the south side of NE 7th Street before patrons will use the remote lot, unless no parking signs are erected and rigorously enforced. Since the property between the remote parking lot and NE 7th Street is not owned by the Applicant, it would be necessary to obtain a written agreement with the owner of 610 N. Parrott Avenue to allow pedestrian access across this private property to access the remote parking area behind Big Lake Eye Care. Without such an agreement, safe and convenient access to the remote lot could not be guaranteed and therefore the remote lot could not be considered to adequately serve the proposed use, as required under §90- 511(a)(2). The Applicant has submitted an agreement with Ms. Anita Nunez, owner of the property at 610 North Parrot Avenue. If the agreement is deemed by the City Attorney to be legally acceptable, this would satisfy this concern. Off - street Loading One required for 5,000 to 25,000 square feet of commercial floor space. None provided. If the remote parking lot is approved, we would recommend that the required loading zone be located in the on- site parking lot. Parking Space Dimensions and Locations If the remote lot is approved, all location and dimensional requirements will need to be met. For example, to avoid conflicts the first parking space should be located 20 feet from the east property line. Minimum Driveway Width 24 -feet for 90 degree parking This will have to be addressed when the site plan for the remote lot is reviewed. Serving Florida Local Governments Since 1988 4 Staff Report Site Plan Review Applicant: CRCO Properties, LLC Petition No.: 13- 002 -TRC Regulation Required Provided Landscaping Requirements for parking and vehicular use areas (Sec. 90 -533) Assuming that no additional parking is provided on site, and no other physical changes are made to the subject site, the property can be considered grandfathered with respect to any need for landscaping and buffering. However, the Applicant will ultimately need to submit a landscape plan for the remote parking lot that meets all of the applicable landscape requirements. Required landscape buffer areas (Sec. 90 -534) Landscape design and plan. (Sec. 90 -538) Other Requirements and Considerations: Sidewalks: There are no sidewalks anywhere along the north side of NE 7th Street. There is a sidewalk along the south side of the street between Parrott Avenue and NE 3rd Avenue. Lighting Plan: If the remote lot is approved, the Applicant will need to submit a photometric lighting plan showing an average of one -half horizontal foot candle, per Sec. 78 -71. Dumpster Location: We could find no dumpster location indicated on the site plan. Serving Florida Local Governments Since 1988 5 Staff Report Site Plan Review Applicant: CRCO Properties, LLC Petition No.: 13- 002 -TRC Recommendation: Based on the foregoing information and analysis, we believe that a remote parking lot in the location proposed by the Applicant could be considered to adequately serve the proposed uses provided the following conditions are met: 1. The City Commission approves the Applicant's request for the use of off -site parking facilities. 2. A legally acceptable agreement, which provides for access through the property at 610 North Parrott Avenue and /or along the public alleyway between NE 7th Street and the proposed remote parking lot, is executed between or among the appropriate parties. 3. The Applicant submits to the City a written agreement ensuring the continued availability of the off -site parking facility for parking use as required under Sec. 90- 511(a)(2). 4. The applicant submits a site plan for the remote parking lot which, together with the on- site parking spaces, provides for at least 40 off - street parking spaces as required by the LDC. The site plan must also meet all other applicable requirements of the LDC as relates to access, size and location of parking spaces, buffering, landscaping and lighting, including the submission of the required landscape and photometric lighting plans. 5. Suitable locations for a dumpster and loading zone are provided on the subject property (704 North Parrott Avenue). 6. Should the City determine that parking signs are needed along the north side of NE 7th Street, between Parrott Avenue and NE 2nd Avenue, the Applicant will be responsible for the cost of the signs and their placement in the right -of -way. Submitted by: Wm. F. Brisson, AICP Planning Consultant April 26, 2013 TRC Hearing date: May 16, 2013 Attachments: Future Land Use Map Zoning Map Aerial showing subject property, remote parking lot, and pedestrian route SeraiostFlare t Lexat G aretE owes iSince t9ha Staff Report Applicant: CRCO Properties, LLC Site Plan Review Petition No.: 13-002-TRC Subject Property FUTURE LAND USE MAP 56 COMPREHENSIVE PLAN LAND USE SINGLE - FAMILY 11111 MULTI - FAMILY 1111 COMMERCIAL INDUSTRIAL PUBLIC FACILITIES RESIDENTIAL MIXED USE Serving Florida Local Governments Since 1988 $11,11111 -1111111MINIMMI111111 7 Staff Report Site Plan Review Applicant: CRCO Properties, LLC Petition No.: 13- 002 -TRC Subject Property ZONING MAP 56 ZONING ▪ CEII - COY, BU ^ NESI: Staff Report Site Plan Review Applicant: CRCO Properties, LLC Petition No.: 13- 002 -TRC AERIAL VIEW OF SUBJECT PROPERTY AND PROPOSED REMOTE LOT AND PEDESTRIAN ROUTE Pedestrian Route • Nearest Parking Space Farthest Parking Space 9 Serving Florida Local Governments Since 1988 CITY OF OKEECHOBEE Application for Site Plan Review Page 1 of 2 ,A.,O 001 c, rtilG 4 t12 ,� fi u. n A rQ ,- p �w 6 s �. 0t 1 4k Airsoier City of Okeechobee General Services Department 55 S.E. and Avenue, Room 101 Okeechobee, Florida 39974 -2903 Phone: (863) 763 -3372, ext. 218 Fax: (863) 763 -1686 e-mail: clement@cityofokeechobee.com Date Received /- Q 0 Application No. 13_ 00A _TC- Fee Paid: on 8 cob q Receipt No. I f �' Hearing Date: APPLICANT INFORMATION 1 Name of property owner(s): CRCO Properties, LLC 2 Owner mailing address:364 NW 115th Street, Okeechobee, FL 34972 13 Name of applicant(s) if other than owner: 4 Applicant mailing address: 5 Name of contact person (state relationship):Steven L. Dobbs, P. E., Engineer 6 Contact person daytime phone(s): 863- 824 -7644 7 Engineer: Name, address and phone number:Steven L. Dobbs, P. E. 1062 Jokes Way Okeechobee, FL 34974 863 - 824 -7644 8 Surveyor: Name, address and phone number: Kenneth Breaux 200 SW 3rd Avenue Okeechobee, FL 34974 863- 763 -2887 PROPERTY and PROJECT INFORMATION 9 Property address/directions to property: 704 North Parrott Avenue OKEECHOBEE, FL 34972 The property is located 1 block south of the CSX Railroad Crossing on Highway 441 N 10 Parcel Identification Number 3- 15- 37 -35- 0010 - 00570 -0180 11 Current Future Land Use designation: Commercial 12 Current Zoning district: Commercial HMV Y CO i' MC irC 1 a 1 l C A v 13 Describe the project including all proposed uses, type of cons }ruction and conceptual building layout, how the business or use is expected to operate on the site, including but not limited to: number of employees expected; hours of operation; location, extent and type of any outdoor storage or sales, etc., and fire flow layout. Use additional page if necessary. This project will convert the existing Retail Furniture Store to a Fitness Center, Nutrition Store, and Warehouse space. All functions will take place inside the building with 3 -5 employees and the hours of operation will be from 6 am until 9 pm. 14 Describe existing improvements on property (for example, the number and type of buildings, dwelling units, occupied or vacant, etc.). Use additional page if necessary. There is an existing 8,000 sf building with associated parking. 15 Total land area in square feet (if less than two acres): 20,908.8 sf or acres: • i_419 (Properly Appal 16 Is proposed use different from existing or prior use (X Yes) ( No) Rev. 04/11 CITY OF OKEECHOBEE Application for Site Plan Review Page 2 of 2 17 Number and description of phases: Single Phase 18 Source of potable water: Okeechobee Utility Authority 19 Method of sewage disposal: Okeechobee Utility Authority For questions relating to this application packet, call the General Services Dept. at (863) - 763 -3372, Ext. 218 Rev. 04/11 ATTACHMENTS REQUIRED FOR ALL APPLICATIONS 20 Applicant's statement of interest in property 0 vv Ile Y 21 One (1) copy of last recorded warranty deed 22 Notarized letter of consent from property owner (if applicant is different from property owner) 23 Three (3) sealed boundary and topographic, "as is" surveys of the property involved including: a. certified boundary survey, date of survey, surveyor's name, address and phone number b. Legal description of site and parcel number c. Computation of total acreage to nearest tenth of an acre 24 Two (2) sets of aerials of the site. 25 Eleven (11) copies of sealed site plan drawings (see attached checklist for details to be included in site plan) 26 Eleven (11) copies of drawing indicating facades for all buildings, including architectural elevations. 27 Eleven (11) copies of landscape plan, including a separate table indicating the number of trees and shrubs by type and showing both the official and common name of each type of tree and shrub. 28 Three (3) copies of sealed drainage calculations 29 Attach a Traffic Impact Study prepared by a professional transportation planner or transportation engineer, if the rezoning or proposed use will generate 100 or more peak hour vehicle trip ends using the trip generation factors for the most similar use as contained in the Institute of Transportation Engineers most recent edition of Trip Generation. The TIA must identify the number of net new external trips, pass -bay calculations, internal capture calculations, a.m. and p.m. peak hour trips and level of service on all adjacent roadway links with and without the project. 30 Nonrefundable application fee: $1,000.00 plus $30.00 per acre. NOTE: Resolution No. 98-11 Schedule of Land Development Regulation Fees and Charges — When the cost for advertising publishing and mailing notices of public hearings exceeds the established fee, or when a professional consultant is hired to advise the City on the application, the applicant shall pay the actual costs. NOTE: The require Submissions will be reviewed by the City Engineer and City Planner for all necessary documentation. Applicant will be notified at least 10 days prior to the TRC meeting whether or not additional information is to proceed or if the review will be rescheduled to the next TRC meeting. Confirmation of Information Accuracy I hereby certify that the information in this application is correct. The information included in this application is for use by the City of Okeechobee in processing my request. False or misleading information may be punishable by a fine of up to $500.00 and imprisonment of up to 30 days and may resulting the summary denial of this application. Dr. Charles Bartels �.1 Signature Printed Name D to For questions relating to this application packet, call the General Services Dept. at (863) - 763 -3372, Ext. 218 Rev. 04/11 Patty Burnette From: Steven Dobbs < sdobbs @stevedobbsengineering.com> Sent: Tuesday, April 02, 2013 10:41 AM To: Patty Burnette Cc: Bartels, Charles Subject: CRCO Properties Patty, As discussed, Dr. Bartels would like to wait until the May TRC meeting and not be on the agenda for April. Please call with any questions. Steven L. Dobbs Engineering, 1062 Jukes Way Okeechobee, FL 34974 Phone: 863 - 824 -764, Cell: 863 - 634 -0194 sdobbs @stevedobbsengineering.com Prepared by and retum to: JOHN D. CASSELS, JR. Partner CASSELS & MCCALL 400 NW 2nd Street Okeechobee, FL 34972 863- 763 -3131 File No.: 6491 Parcel Identification No. 3-15-37-35-0010-00570-0180 l is ip,- loco-0u 111119111111iu11111 iiiizaii11111111 OR E'k 00721 PG 0624 SHARON ROBERTSON, CLERK OF CIRCUIT COURT OKEECHOBEE COUNTY, FLORIDA RECORDED 10/23/2012 11:39 :34 AO ANT 150,000,00 RECORDING FEES $10.00 DEED DOC $1,050,00 RECORDED BY S Creech Ps 0624; (los) [Space Above This Line For Recording Data) Warranty Deed (STATUTORY FORM - SECTION 689.02, F.S.) This Indenture made this 23rd day of October, 2012 Between ELLIS R. HAYDON and RITA A. KOGER HAYDON, his wife whose post office address is 2448 NE 80th Avenue, Okeechobee, FL 34972 County of Okeechobee, State of Florida, grantor*, and CRCO PROPERTIES, LLC, a F o da 1 ted liability company whose post office address is 364 NW 115th Drive, Okeechobee, FL 34972 o Ira - . of Okeechobee, State of Florida, grantee *, Witnesseth that said grantor, for a other good and valuable consideration acknowledged, has granted, bargained, and" following described land, situate, lyin Lots 18, 19 and 20, Block 57, OKEECHOBEE, a 5, Public Records of Okeechobee Coun Flo eration of the sum of TEN AND NO /100 DOLLARS ($10.00) and ntor in hand paid by said grantee, the receipt whereof is hereby the said grantee, and grantee's heirs and assigns forever, the keechobee County Florida, to -wit: ng to the plat thereof recorded In Plat Book 5, Page Subject to restrictions, reservations and easements of record, if any. and said grantor does hereby fully warrant the title to said land, and will defend the same against lawful claims of at persons whomsoever. • "Grantor" and "Grantee" are used for singular or plural, as context requires. In Witness Whereof, grantor has hereunto set grantor's hand and seal the day and year first above written. Signed, sealed and delivered in our presence: (.0 Witness ame: RP /'r L- t°I-<I /.Al 1 k .At I/L1IL_L Wi -s ~Mid,., • : State of Florida County of Okeechobee ELLIS R. HAYDON The foregoing instrument was acknowledged before me this 23rd day of October, 2012 by ELLIS R. HAYDON and RITA A. KOGER HAYDON, who L] are personally known or [X] have pr du d a driver's Iicen as identification. [Notary Seal] Not. Public Printed Name: Sta 4(1'11 01611 -S My Commission Expires: K Publicp ate of flog a Mt Commi.ion 6E119767 or ^ 6XpVs 60/07!2015 Book721 /Page624 CFN #2012010815 Page 1 of 1 DSearchResults Okeechobee County Property Appraiser CAMA updated: 1/10/2013 Parcel: 3-15-37-35-0010-00570-0180 « Next Lower Parcel Next Higher Parcel » Owner & Property Info Owner's Name CRCO PROPERTIES LLC Site Address 704 N PARROTT AVE, OKEECHOBEE Mailing 364 NW 115TH DR Address OKEECHOBEE, FL 34972 Description CITY OF OKEECHOBEE LOTS 18 TO 20 BLOCK 57 NOTE: This description is not to be used as the Legal Description for this parcel in any legal transaction. Land Area 0.479 ACRES S /T /R 15 -37- 35 Neighborhood 518620.00 Tax District 50 DOR Use Code STORES /1 S (001100) Market Area 40 The DOR Use Code shown here is a Dept. of Revenue code. Please contact the Okeechobee County Planning & Development office at 863 - 763 -5548 for specific zoning information. Property & Assessment Values Mkt Land Value cnt: (1) $99,114.00 Ag Land Value cnt: (0) $0.00 Building Value cnt: (1) $186,813.00 XFOB Value cnt: (5) $25,550.00 Total Appraised Value $311,477.00 Sales History Page 1 of 2 2012 Certified Values Parcel List Generator 2012 TRIM (pdf) ) GIS Aerial Retrieve Tax Record Property Card Interactive GIS Map (Print) Search Result: 1 of 1 2012 Certified Values Just Value $311,477.00 Class Value $0.00 Assessed Value $311,477.00 Exempt Value $0.00 Total Taxable Value $311,477.00 Show Similar Sales within 1/2 mile Fill out Sales Questionnaire Sale Date Book/Page Inst. Type Sale Vlmp Sale Qual Sale RCode Sale Price 10/23/2012 721/624 WD I Q 01 $150,000.00 Building Characteristics Bldg Sketch Bldg Item Bldg Desc Year Blt Heated S.F. Actual S.F. Bldg Value Show Sketch 1 STORE RETL (003500) 2001 5950 8550 $186,813.00 Extra Features & Out Buildings - ( Show Codes ) Code Desc Year Blt Value Units Dims Condition (% Good) CONC I BUMPERS 2001 $105.00 0000009.000 0 x 0 x 0 PD (085.00) FENC A 6'C /L 3BRB 2001 $2,128.00 0000235.000 0 x 0 x 0 PD (085.00) CONC E CURB 2001 $298.00 0000054.000 0 x 0 x 0 PD (085.00) CONC B COM SLB WL 2001 $310.00 0000160.000 0 x 0 x 0 PD (085.00) CONC B COM SLB WL 2005 $22,709.00 0011718.000 0 x 0 x 0 PD (085.00) http://www.okeechobeepa.com/GIS/D_SearchResults.asp 1/15/2013 SOUTH FLORIDA WATER MANAGEMENT DISTRICT Delivered Via Email Regulation Division February 4, 2013 Mr. Steve Dobbs Steven L. Dobbs Engineering, LLC 1062 Jakes Way Okeechobee, FL 34974 Subject: C R C 0 Fitness Environmental Resource Permit Application No. 130110 -2 Okeechobee County Dear Mr. Dobbs: District staff has reviewed the above - referenced application and has determined that additional information will be required to complete the application. In accordance with Rule 40E- 1.603, Florida Administrative Code (FAC), the District is requesting the following information to complete the application and provide reasonable assurances for permit issuance: 1. The proposed construction of the parking lot, driveway and associated surface water management facilities do not qualify for a No Notice or Noticed General Environmental Resource Permit (Rule 40E- 400.315(e) and 40E- 400.439(f) FAC). Please be advised that the required permit processing fee for a (non - agricultural) standard general permit is $3,500.00. Please submit a check for the outstanding fee. Further, in order for staff to complete their review of the project, please submit the items listed in Sections C and E of the permit application form. Additional comments may be issued once staff has had an opportunity to review the requested information. 2. Section 5.2.1 of the District's Basis of Review (BOR) requires that projects provide water quality treatment for the greater of the first inch of runoff, or 2.5" times the percentage of impervious. Please provide calculations which demonstrate the foregoing. What are the provided water quality treatment volume and overflow elevation, and the mechanism for providing this volume, as indicated on the drainage plans? If the water quality treatment provided is less than required an explanation must be submitted for staff review that explains why additional water quality treatment cannot be provided. 3. With regard to exfiltration trench calculations, the depth to the water table (H2) should be the lesser of the distance between the control elevation (el. 25.35' NGVD) and the lowest grate elevation, or the lowest overflow elevation. Similarly, the unsaturated trench depth DISTRICT IIh:ADQUAii'I'ERS: 3301 Gun Club )load, West Palm Bach, Florida 33406 • (561) 686 -8800 • (800) 432 -2045 Mailing lddress: PC) BOX 24680 West Palm Reach Fl 33416 -4680 TOWER WEST COAS1 SERVICE: C:EiN I'ER: 2301 McGregor Boulevard, Fort Myers. FL 33901 • (239) 338 -2929 • (800) 248 -1201 Okr-I CIIOBEE SERVICE CENTER: 3800 NW 16 "' Blvd., Suite A, Okeechobee, FL 34972 • (863) 462 -5260 • (800) 250 -4200 (1R) ANDO SEIRVIC'F. CENTER: 1707 Orlando Central Parkway, Suite 200, Orlando FL 32809 • (407) 858 -6100 • (800) 250 -4250 Mr. Steve Dobbs C R C 0 Fitness, Application No. 130110 -2 February 4, 2013 Page 2 grate elevation, or the lowest overflow elevation. Similarly, the unsaturated trench depth (Du) should also be calculated based upon the minimum of the overflow elevation or the minimum grate elevation (Section 5.4 BOR). 4. Please provide documentation from the City of Okeechobee which demonstrates that the applicant has authorization for paving and drainage improvements within the 7th Street right -of -way. This documentation shall also address who will be responsible for operation and maintenance of the piping network/SWM system for State Route 441 and the city street (Rule 40E- 4.381(i), (k) FAC. 5. Will temporary dewatering be required as part of the construction activities? Please contact Eve Raymond, or Matt Stahley, Scientist 2- Hydrogeology at 863 -462 -5260 ext. 3032, to determine if a Water Use Permit(s) will be required for dewatering. Because of the inseparable nature of water use and surface water management, and in accordance with Rule 3.2(b), Basis of Review for Environmental Resource Permit Applications, District staff will review these applications concurrently and final agency action will be taken only when both applications have been deemed complete. Advisory Comment: The following comment is advisory in nature and does not require a response to the District. A1. Included with this letter /permit is a brochure from the Florida Department of Environmental Protection (FDEP) on Florida's National Pollutant Discharge Elimination System (NPDES) program for construction activities. As the brochure indicates, the U.S. Environmental Protection Agency authorized the FDEP in October 2000 to implement the NPDES stormwater permitting program in Florida. The District is assisting FDEP by distributing this information to entities which may be subject to regulation under the NPDES program. No response to the District is required. A "Generic Permit for Stormwater Discharge from Large and Small Construction Activities" (CGP) is required for a construction activity which ultimately disturbs an acre or more and contributes stormwater discharges to surface waters of the State or into a municipal separate storm sewer system. The permit required under FDEP's NPDES stormwater permitting program is separate from the Environmental Resource Permit required by the District. Receiving a permit from the District does not exempt you from meeting the NPDES program requirements. If you have any questions on the NPDES Stormwater program, call 866 - 336 -6312 or email FDEP at NPDES- stormwater(cr?.dep.state.fl.us. For additional information on the NPDES Stormwater Program including all regulations and forms cited in the brochure visit: www.dep.state.fl.us /water /stormwater /npdes/ . Mr. Steve Dobbs C R C 0 Fitness, Application No. 130110 -2 February 4, 2013 Page 3 Please submit responses to this letter electronically on the District's ePermitting website (www.sfwmd.00v /ePermittinq) to expedite administrative processing of the application and to save paper. Please note that an electronic response may be submitted even if the original application was submitted via hard copy. A brochure regarding the District's comprehensive ePermitting program is enclosed. Alternatively, please provide one (1) original and one (1) copy of the requested information, clearly labeled with the application number, to the Okeechobee Service Center. In accordance with 40E- 1.603(1)(b) FAC, if the requested information is not received within 90 days of the date of this letter, this application may be processed for denial, if not withdrawn by the applicant. If additional time is needed, please contact one of the District staff members below with a request for an extension before the 90 day period ends. The District recommends contacting the assigned staff members to resolve the above questions and concerns prior to submitting a response. Carolyn McCreedy, Engineering Specialist 4 at 863- 462 -5260 ext. 3042, or via email at cmccreed(cr,sfwmd.gov; and Eve Raymond, Environmental Analyst 3 at 863- 462 -5260 ext. 3007, or via email at sravmon @sfwmd.Qov are available to assist with questions. Sincerely, Kelly Cranford, P.E. Section Leader Agricultural Water Programs South Florida Water Management District r -� KC /cm Enclosure cc: C R C 0 Properties LLC City of Okeechobee Okeechobee County Planning FDOT Sebring Operations (Larry Ransom) Mr. Steve Dobbs C R C 0 Fitness, Application No. 130110 -2 February 4, 2013 Page 4 Internal distribution (via email): SW Reviewer- Carolyn McCreedy ENV Reviewer- Eve Raymond Compliance -Wayne Blythe Kelly Cranford, Ag Team Section Leader Barbara Conmy, ENV Section Leader WU— Matt Stahley Addresses Mr. Charles Bartels C R C 0 Properties LLC 364 NW 15th Drive Okeechobee, FL 34972 FOOT Sebring Operations 4722 Kenilworth Blvd. Sebring, FL 33870 CRCO Properties, LLC City of Okeechobee Site Plan Application Front View, South Side of Building CRCO Properties, LLC City of Okeechobee Site Plan Application Rear View, North Side of Building CRCO Properties, LLC City of Okeechobee Site Plan Application CRCO Properties, LLC City of Okeechobee Site Plan Application Side View, West Side of Building Engineer's Report CRCO Fitness for CRCO Properties, LLC City of Okeechobee, Florida Prepared January 2013 By: Steven L. Dobbs, P.E. # 48134 Steven L. Dobbs Engineering, LLC Florida Certificate of Authorization No. 00029206 1062 Jakes Way Okeechobee, FL 34974 5 i NOr f ,, •. y Purpose: The purpose of this report is to provide the South Florida Water Management District (SFWMD), the City of Okeechobee and the Florida Department of Transportation with the calculations and documentation necessary to demonstrate the proposed surface water management system complies with state and local criteria. Existing Conditions: The site is approximately 0.48 acres in size with a parcel number of 3- 15- 37 -35- 0010 -00570 -0180 and is located in Section 15, Township 37 South, Range 35 East. This project is located approximately 1 block south of the CSX railroad crossing on Highway 441N, the City of Okeechobee, FL. The site currently discharges through the 7th Street Ditch on the south side of the property and the ditch discharges to Taylor Creek to the east and Taylor Creek Discharges into Lake Okeechobee.. Proposed Use: The owner proposes modify the existing site plan to include additional parking and change the use of the building from retail furniture sales to a fitness center. The plan will also cover 7th Street Ditch south of the property and permitting is in process with the Florida Department of Transportation to receive their approval. The water quality requirements of the additional parking will be met by installing 72 If of exfiltration trench prior to the runoff discharging into the 7th Street Ditch. This exfiltration will provide the required 0.05 ac -ft of water quality treatment. Parkin Considerations: Parking for the 8,000 sf building is provided based on a 5,000 sf fitness center, 1,500 sf of warehouse, and 1,500 sf of a nutrition store. The fitness center requires 1 parking space for every 150 sf or 33.3 spaces, the warehouse will require 1 space for every 1,000 sf or 1.5 spaces, and the nutrition store requires 1 space for every 250 sf or 6 spaces for a total of 41 required spaces. According to 2000 International Building Code, for 25 to 49 parking spaces there are 2 handicapped parking spaces required and 2 are provided. While there are a total of,3.7 spaces provided, we are requesting the TRC to recommend to the City Council for a parking reduction.AThe typical parking reduction is 20 %, while our request is for only 10 %. 34) Drainage Considerations: To provide the water quality treatment requirements of the additional parking area, all drainage will pass through the proposed 72 If of exfiltration trench. The exfiltration trench will be controlled at 27.35 or the top of the exfiltration trench as required by South Florida Water Management District Criteria. The bottom of the exfiltration trench pipe will be located at elevation 25.35 or the wet season water table as established by AM Engineering in the attached report. The Soils Map for Okeechobee County indicates that this parcel's soils are made up of 100.0 % Immokalee Fine Sand. This soil type is are very poorly drained "D soil" in the natural state and better drained "B soil" in the developed state. The site is currently developed and is located in the S -133 Basin with an allowable discharge of 15.6 CSM for a 25 year — 3 day event. The project will drain through the onsite exfiltration trench and into the adjacent 7th Street Ditch to the east which proceeds south into Taylor Creek. Allowable discharge for the project based on Pre vs Post calculations is 15.6 csm: Q = 15.6 csm / 640 acres * A Q= 15.6 csm /640 acres * 0.48 Acres =0.12 cfs 2 Technical Data Total Site Area: Project Drainage Area: 0.48 acres 0.80 acres Determine Curve Number: See attached spreadsheet for Curve Number Calculation A. Water Quality Water quality treatment is provided in the form of dry retention with an under drain for the project drainage area. Water quality calculations are provided on the attached spreadsheet. For Drainage Area: See attached spreadsheet for water quality calculations Based on the attached stage storage spreadsheet, the water quality volume is exceeded at elevation 29.7. B. Water Quantity This project is located in the S -133 Basin which discharges to the south into Lake Okeechobee. The allowable discharge in this project is 15.6 csm, therefore the allowable discharge for the 25 -year, 72 -hour storm event for this project was calculated to be 0.12 cfs. There are no anticipated tailwater issues since the project will discharge into an open adjacent ditch. The actual maximum discharge for the 25 -year 72 -hour storm event is 2.214 cfs, which exceeds allowable discharge, however, this is an existing site and water quality is only being provided for the additional parking area and no water attenuation is proposed. To demonstrate conformance to this criteria, the proposed project was flood routed using AdICPR. The 10 year, 24 hour storm (5.0 ") w /discharge, the 25 year, 72 hour storm (9.0 ") w /discharge, and the 100 year, 72 hour storm (10.0 ") w/o discharge has been evaluated based on the proposed plan. Please refer to the attached AdICPR flood routing input/output parameters. A summary of the flood routings is provided as follows: 10 Year Storm (5.0") Peak Stg Peak Rate (ft -NGVD) (cfs) 27.52 2.003 25 Year Storm (9.0 ") Peak Stg Peak Rate (ft -NGVD) (cfs) 100 Year Storm (10.0 ") Peak Stg (ft -NGVD) 28.10 2.214 29.77 Florida Department of Transportation (FDOT) Since the owner is proposing to fill the ditch and replace the existing 42" culvert under the drive and install a 48" culvert, FDOT requested this ditch be modeled, which was done and completed successfully. The modeling show no adverse water levels and actually reduced water levels within the ditch in the post condition. Please see attached analysis. Off -site Drainage: There is no off -site drainage included in the property. Environmental: There are no jurisdictional wetlands onsite. 3 Construction Recommendations: Run -off and any water generated by short-term dewatering generated during construction shall be contained on -site. However, there is some potential for transport of sediment to off -site areas should heavy rainfall occur. We therefore recommend installation of temporary silt fence around the entire construction area during site work to reduce the potential of any off -site transport of sediment or turbidity. Conclusions: In my professional opinion, the proposed construction should have no impact to existing drainage patterns off -site and should have no impact on off -site areas. The recommendations above should be followed during and after the site work until such time as the ground surface has been adequately stabilized to prevent the off -site transport of any soil or suspended solids. The proposed design and construction will meet all local, state and federal requirements. 4 CRCO Properties Project No.2012 -041 Exfiltration Calculations Exfiltration Design for Additional Parking Water Quality Treatment Volume The required water quality treatment volume for the additional parking of 7,000 sf is 2.5 times the impervious area plus an additional 50% for a total volume of 0.05 ac -ft. Converted to length of exfiltration trench: 0.05 ac -ft = 0.60 ac -in WEIR EL 27.35 WATER TABLE V EL: 25.35 #4 COARSE AGGREGATE t' NIN. OVERLAP GRADE- 29.50 MIRAFI 700X FILTER FABRIC EL. 24.35 EXFILTRATION TRENCH SECTION L = V / (k * (H*W + 2 *H *DU - DU *DU + 2 *H *DS) + (0.000139 *W *DU)) Where V = Volume (Ac. -In.) = 0.60 Ac -In. k = Hydraulic Conductivity = 1.84E -04 cfs /Ft ^2 -Ft -Hd H = Water Table Depth = 4.0 Ft. W = Width of Trench = 4.0 Ft. DU = Unsaturated Depth = 2.5 Ft. Ds = Saturated Depth = 1.0 Ft. L = 0.60 / (0.0001840 * (4 *4 + 2 *4 *2.5 - 2.5 *2.5 + 2 *4 *1) + (0.000139 *4 *2.5)) = 0.60 / (0.006946 + 0.001390) = 71.98 Ft. Required Length of trench = 72 feet CRCO Properites Project No. 2012-041 Drainage Calculations Basin Information For: CRCO Properties - CRCO Property' Total Basin Area 0.80 an Wetland 0.00 ac Wetland Buffer / Preserve 0.00 ac Total Basin Area (water quality) 0.80 as Impervious Area Roofline/Bldg. 0.18 ac Wetland 0.00 as Lakes = 0.04 ac Pavement /Sidewalk = 0.50 ac Total Impervious Area = 1172 ac Impervious Area Ditch 0.00 ac Green = 0.08 ac Total Pervious Area 0 00 ac Percent Impervious = 90 0' o Adjusted Soil Storage = 0 03 in Calculated SCS Curve Number = 96 Time of Concentration = n 0i • mm Water Oualitv Calculation 1" x Total Area Runoff from 2 5 "x % net Impervious - SFWMD criteria Required Water Quality Volume Dry Detention Muhupher Adjusted Required Water Quality Volume 0.5 Water quality stage (0.0767001186986171 ac -ft) Water Quality Stage 0 37 ac -ft 14 ac -ft n 14 ac -ft 1.13 15.075 n15 ac-ft 28 ft-NGVD 2004 ft -NGVD Stage Storage Calculations for Basin CRCO Properties - CRCO Property Land use Category Storage Type Area (a6.) From Elev. To Elev. Cumulative Stage - Storage (ac-ftl 22.00 23.00 24.00 25.00 26.00 27.00 28.00 29.00 30.00 31.00 32.00 Exf ltration Vertical 0.05 23.35 000 000 0 02 0 03 0.04 0 05 0 05 0 05 0 05 0 05 0.05 Dry Retention Banks Linear 0.00 20.50 28.50 0 00 000 0,00 000 000 000 0,00 0,00 0.00 000 0 00 Extstmg Budding Vertical 0 18 29,00 000 000 0 00 000 0 00 0 00 000 000 0 18 0 37 0 55 Proposed Building Vertical 0.00 38.00 000 0 00 0 00 000 0 00 000 0 00 0.00 0,00 000 0.00 Existing Pavement Linear 0 50 29.00 29.50 000 000 0 00 0 00 000 0 00 000 0.00 0 37 0.87 1 36 Proposed Pavement Linear 0 00 34.50 36.00 0.00 0.00 0 00 000 0.00 000 0.00 0.00 0 00 000 000 Exisrtng Concrete Linear 0 00 30.00 31.60 0 00 0.00 0 00 000 000 0 00 000 000 0 00 000 000 Proposed Concrete Linear 0.00 34.50 35.00 0.00 0.00 0,00 0,00 0.00 0 00 0 00 0 00 0 00 000 000 Green Linear 0.08 27.00 29.00 0.00 0.00 0.00 0,00 0.00 000 0 02 0.08 0 16 0 24 0 32 Total: a 01 Totals: 0,00 0.00 0.02 0.03 0.04 0.05 0.07 0.13 0.77 1.53 2.29 1/4/2013 912012-041 Bartels Rite \04-Catcs12012-041 sr* into crco.xls Basin Information For: Total Site Area Total Basin Area Impervious Area RooflineBidg Wetland Lakes Pavement/Sidewalk Total Impervious Area Total Pervious Area Percent impervious Adjusted Soil Storage Calculated SCS Curve Number Time of Concentration Design Elevations Glades Newland, LLC - Turtle Cove Expansion Project No. 2010-205 Drainage Calculations CRCO Properties - CRCO Property Zero Discharge Storm Stages Min. Req Road Crown Elev. (10 yr -24 hr storm) Min. Req Perimeter Berm Elev. (10 yr -72 hr storm) Min. Req F.F.E. (100 yr -72 hr zero discharge) Stage 0.80 ac 10 -year, 1-day P,0= 5.00 in V =(0 500-0 2(003)^2)/(500-0.8(0.03)0 *080/12= 031 ac -ft 25.66 ft-NGVI) 10 -year, 3-day P25 = 7.00 in V =(((700 -0 2(003)) ^2)/(700. 08(0.03))) *0.80 /l2 = ii 46 ac -ft 25.76 ft -NGVD 100-year. 3-day Fast 10.00 in V =(010.00-0.2( 003) ^2)/(10.014)8/003))) *080/12= 1140 ac -ft 25.92 ft -NGVD 0.80 ac 0.18 ac 0.00 ac 0.04 ac 0.50 ac ac (/ 60 0o i .)O U °'o 0113 m 96 U ++n min 25.66 ft-NGVD 25.76 ft -NGVD 25 92 ft -NGVD Control Structure Design Max Allowable Discharge Control Elevation Req Weir Crest Elevation Pro. Weir Crest Elevation Provided Water Quality Bleed Down Volume Allowable Bleeder Discharge 0.02 cfs 27.80 ft -NGVD 31.60 ft-NGVD 31.60 ft-NGVD 1.83 ac -ft + i +_' ac ft 6 46 cfs Circular Orifice Design: Q = 0.6 *A *(2'g *H)u 5 Solving the above equation for Diameter yields D = 2 *(Q /(0 6 *tt *(2 *g* H)n 5))0 5* 12 in/Ft Assuming 3 -inch bleeder initially 13 2 *[0 46/(0 6 *3 4l4 *(2 *32 2 *(31 60-(27 80+0 125)))^0 5)] ^0 5.12 in/Ft 13 1/2 detention volume 63 in for one bleeder Q = 3.13 *L *H' 5 solving for L, L = Q /(3.13 *Hi 5), use 25 -year, 3-day zero stage for initial head on weir. L =0.02/(3.13 *(25.76. 31.60) ^1.5)= #NfUM! ft Stage Storage Calculations for Basin CRCO Properties - CRCO Property Land use Category Storage Type Area (ac.) From Elev. To Elev. Cumulative Stage- Storage (ac -ft) 22.00 22.50 2.3.00 23.50 24.00 24.50 25.00 25.50 26.00 26.50 27.00 Exfiltranon Vertical 0,05 23.35 0.00 0 00 0 02 0 03 0 04 0 05 0 05 0 05 0 05 0 05 0 05 Retention Banks Linear 0.00 20.50 28.50 0.00 0.00 0.00 0 00 0.00 0.00 0.00 0 00 0.00 0.00 0 00 .y Existing Building Vertical 0.18 29.00 000 0 00 0 00 0 00 0 00 0 00 0 00 0 00 0 18 0 37 0 55 Proposed Budding Vertical 0.00 38.00 0.00 000 0 00 000 0 00 0 00 000 0 00 0.00 0 00 0 00 Existrn8 Pavement Linear 0 50 29.00 29.50 0.00 000 0 00 0 00 0.00 0 00 0,00 0.00 0.37 0 87 1.36 Posed Pavement Lrnear 0.00 34.50 35.00 0 00 000 0.00 0 00 0 00 0 00 0 00 0 00 000 0 00 0 00 Exisitng Concrete Linear 0.00 30.00 31.60 0.00 0.00 0.00 0.00 0 00 0.00 0 00 000 0.00 0,00 0 00 Proposed Concrete Linear 0.00 34.50 35.00 0 00 0 00 0 00 0 00 0.00 0 00 0 00 0.00 0 00 0.00 0 00 Green Linear 0.08 27.00 29.00 0 00 000 0 00 0 00 0 00 0 00 0 02 0 08 0 16 0 24 0 32 Taal: o 8I Totals: 0.00 0.00 0.02 0.03 0.04 0.05 0.07 0.13 0.77 1.53 2.29 1/4/2013 C 12012 -041 Bartels Rda/04- Calcs12012 -041 site info crco.xls Florida's Leading Engineering Source Environmental • Geotechnical • Construction Materials Testing • Threshold and Special Inspections • Plan Review & Code Compliance Steven L. Dobbs Engineering, LLC 1062 Jakes Way Okeechobee, Florida 34974 December 11, 2012 Subject: Geotechnical Services for Stormwater Management Planning 704 N Parrott Avenue Okeechobee, Okeechobee County, Florida GFA Project No. 12- 2292.00 Ladies and Gentlemen: We are pleased to submit this geotechnical report for the referenced project. This letter describes the project, field explorations, results of testing, findings, and information from outside references. PROJECT DESCRIPTION Based on a site plan (reproduced as the Boring Location Plan attached to this report) and conversations with the client, the project consists of constructing new pavement and parking areas with an exfiltration system. FIELD EXPLORATIONS The subsurface conditions at the project site were explored on December 3, 2012, with three Auger borings. Subsequently an Exfiltration (EX) test was conducted in one borehole (AB -1). The auger borings were performed in general accordance with ASTM D 1452, "Practice for Soil Investigation and Sampling by Auger Borings ", and the exfiltration test with the SFWMD Usual Open Hole Test procedure. Hand Cone Penetrometer (HCP) readings were taken at one -foot intervals in the auger borings. The HCP test, in conjunction with information about the soil type, is empirically correlated to the relative density of subsurface soils. The borings and exfiltration test were completed at the approximate locations noted on the Boring Location Plan. The Exfiltration Test Report with the logs from the auger borings are attached. GPS coordinates obtained at boring locations are noted on logs. The depths on the boring logs are below the existing ground surface at the time the borings were performed. FINDINGS The project site was generally flat and grassy with oak and palm trees. The grade at the site was estimated to be 1/2 feet above the adjacent road at the time of the explorations. One -story PORT ST. LUCIE • JACKSONVILLE • ORLANDO • DELRAY BEACH • BOCA RATON • FORT MYERS • TAMPA 521 N.W. Enterprise Drive • Port St. Lucie, Florida 34986 • (772) 924.3575 • (772) 924-3580 (fax) • www.teamgfa.com Geotechnical Services for Stormwater Management Planning 704 N Parrott Okeechobee, Okeechobee County, Florida GFA Project No. 12- 2292.00 December 11, 2012 Page 2 structures were located adjacent to the property. A one -story metal building and asphalt parking lot occupied the site. The subsurface soils encountered in the borings generally consisted of fine sand to a depth of 31/2 feet, very dark brown organically stained sand with little silt that was non - cemented to weakly cemented (hardpan) from 31/2 to 41/2 feet, and then sand to the boring termination depths of 6 feet. The HCP values generally indicated that the soils were medium dense from the ground surface to the bottom of the borings at depths of 6 feet. Ground water was encountered 5 to 6 feet below existing grade at the boring locations. USGS TOPOGRAPHICAL AND USDA SOIL SURVEY INFORMATION We reviewed the USGS 7.5- minute series quadrangle topographic map of the area, entitled Taylor Creek SE. Revisions to this map were based on aerial photographs taken in 1972. The USGS map showed the project site is located on a broad area with an elevation about 30 feet NGVD. The site is within a residential and commercially developed area. The Taylor Creek is about 2100 feet east of the site. The site is shown on sheet numbers 43 and 46 of the Soil Survey of the Okeechobee County Area, Florida, issued by the U.S. Dept. of Agriculture in March 1980. According to the Soil Survey, Immokalee fine sand (11) occur at the site. The Soil Survey describes Immokalee fine sand (11) as poorly drained soil in broad areas of flatwoods. The soil profile consists of fine sand to fine sand with little silt from the ground surface to a depth of 3 feet, underlain by fine sand with little to some silt to a depth of 6% feet. With unimproved drainage, the seasonal high water table is apparent and at a depth of 6 to 18 inches below the ground surface from June through September. During the remainder of the year, it is typically at a depth of 18 to 40 inches. Permeability is rapid in the surface and subsurface layers and moderate to moderately rapid in the subsoil. The subsurface layer extends to a depth of 3 feet and the subsoil to a depth of 41/2 feet. It should be noted that the Soil Survey generally extends to a maximum depth of 80 inches (approximately 6% feet) below ground surface and is not indicative of deeper soil conditions. SOUTH FLORIDA WATER MANAGEMENT DISTRICT RAINFALL INFORMATION According to the SFWMD web site the rainfall in the Lake Okeechobee area from December 1 to 3, 2012 was 0.03 inches (29% of normal for that time of month, normal monthly total for all of December is 0.62 inches), for the month of November 2012 was 0.16 inches (8% of monthly normal), for the month of October 2012 was 3.86 inches (130% of monthly normal), and for the month of September 2012 was 6.05 inches (108% of monthly normal). The year to date to the end of November 2012 was 43.52 inches (102% of monthly normal). The 2011 total rainfall was 38.73 inches (88 percent of normal). G0 Geotechnical Services for Stormwater Management Planning 704 N Parrott Okeechobee, Okeechobee County, Florida GFA Project No. 12- 2292.00 December 11, 2012 Page 3 DISCUSSION AND CONCLUSIONS The subsurface soils encountered in the auger boring corresponded well with the information presented in the Soil Survey. The recent rainfall history indicates that the observed water table level should be about normal for this time of year. Drainage improvements in the vicinity indicate the average wet season high water table should be below that stated in the Soil Survey. Based on the above data and the results of our field exploration, we estimate that the average wet season high water table level is 33/ feet below the ground surface at the boring locations. However, should rainfall intensity and duration or total rainfall quantities exceed the normally anticipated rainfall quantities, the groundwater level may exceed our estimate of the average wet season high groundwater level. The top of a very dark brown organically stained sand with little silt that was generally non - cemented to weakly cemented (hardpan) layer was encountered at depths of 31/2 feet, and had layers about 1/2 to 1 foot thick in the borings. This soil has a low permeability. Also, it should be noted for drainage system design that the soil layer described by the soil survey as sand with little /some silt has a low permeability. The Soil Survey generally gives the coefficient of permeability for this material as less than 0.4 feet per day (1.4 x 10 cm /sec). Based on our experience the coefficient of permeability ranges from 0.01 to 0.1 feet per day (104 to 10 -5 cm /sec) for these low permeability soils. "Perching" of the ground water on top of these layers after rainfall should be expected. PAVEMENT RECOMMENDATIONS General Based on the borings, the soils are suitable for support of access drives and parking areas using typical pavement profiles. Construction of the roads should conform to the latest FDOT specifications. Generally a flexible asphaltic concrete pavement will require a higher quality deeper subgrade than a rigid concrete pavement. Either rigid or flexible pavement sections can be used in areas traveled by light autos, pickup trucks and smaller delivery vehicles. We recommend rigid pavements for zones traversed by heavy trucks as well as dumpster pads. The pavement section should be designed for the anticipated vehicle loads and frequencies. We recommend that the proposed pavement grades provide at least 18 inches of separation between the bottom of the base course or the concrete slab and the average wet season high water table. Good drainage is essential for longevity of pavements. Care should be taken to prevent access of irrigation water from landscaped areas to the base and subgrade courses beneath both rigid and flexible pavements. The resultant saturation will result in subgrade /base failure and the rapid deterioration of the pavement surface. G0 Geotechnical Services for Stormwater Management Planning 704 N Parrott Okeechobee, Okeechobee County, Florida GFA Project No. 12- 2292.00 December 11, 2012 Page 4 The pavement area should be prepared in accordance with the "Site Preparation Recommendations - Pavement" section of this report. Rigid Pavements Rigid (concrete) pavements generally provide durability, strength and longer life. Our rigid pavement design is based on ACI Standard 330R -01, "Guide for Design and Construction of Concrete Parking Lots ". The recommended pavement thicknesses presented in the following table are predicated on preparation and compaction of the subgrade as recommended in this report, a modulus of subgrade reaction (k) of 150 pci, a 20 -year design life, and the specified average daily truck traffic (ADTT). MINIMUM RIGID PAVEMENT THICKNESS AND JOINT SPACING Unreinforced Portland Cement Concrete Pavements — No Dowels Service Level Concrete Thickness Maximum Joint Spacing Light 4.5 inches 10.0 feet Medium 5.0 inches 12.5 feet Heavy 5.5 inches 12.5 feet Dumpster pad and Apron 7.0 inches 15.0 feet Light: Medium: Heavy: Automobiles, light panel and pickup trucks and limited heavy truck traffic, ADTT = 1 Automobiles, Tight panel and pickup trucks and limited heavy truck traffic, ADTT = 10 Automobiles, light panel and pickup trucks and limited heavy truck traffic, ADTT = 25 Uniformity of subgrade support, rather than high subgrade strength, is a key factor in concrete pavement performance. The upper 2 feet of the subgrade should be compacted to a minimum of 98% of the modified Proctor maximum dry density (AASHTO T180), and a stable, unyielding surface must be achieved at the subgrade level. The concrete should have a minimum 28 -day flexural strength (modulus of rupture) of 600 psi based on the third point loading of concrete beam test samples. Because beam tests are not typically performed for this size project, we recommend that the concrete have a minimum 28 -day compressive strength of 4,500 psi (based on published correlations between compressive strength and flexural strength, Figure 2.1 of ACI 330R -01). The joints should be sawed as soon as the pavement can withstand traffic, but not so soon as to cause raveling of the concrete surface and aggregate during sawing. 60 Geotechnical Services for Stormwater Management Planning 704 N Parrott Okeechobee, Okeechobee County, Florida GFA Project No. 12- 2292.00 December 11, 2012 Page 5 Flexible Pavements For construction of typical flexible pavement sections, we recommend that the upper 2 feet of soil immediately below the stabilized subgrade (or base course if stabilized subgrade is not used) be compacted to a minimum of 98% of the modified Proctor maximum dry density (AASHTO T -180), and a stable, unyielding surface must be achieved at the subgrade level. While a three -layer pavement section consisting of stabilized subgrade, base course and surface course can be used, a two -layer pavement section that has a thicker base course (equivalent when substituted for the stabilized subgrade) with a surface course can be used. We have included the typical designs for alternate traffic volumes and types. The designs are based on structural number analyses with the stated estimated daily traffic volumes for a 20- year pavement design life and terminal serviceability value, Pt, of 2.5. For loading conditions greater than those presented in the following table, a pavement design should be made for the projected traffic data. The stabilized subgrade should have a minimum LBR value of 40, and should be compacted to at least 98% of the modified Proctor maximum dry density (AASHTO T -180). The base course should be free draining FDOT approved limerock or coquina (or equivalent) with a minimum LBR value of 100. The base course should be placed in lifts not to exceed 6 inches, and compacted to at least 98% of the modified Proctor maximum dry density (AASHTO T- 180). The surface course should be designed and tested in accordance with the current FDOT specifications. Utility Installation Dewatering will be required for the installation of some of the underground utilities. In the locations that were explored, the excavated soils from the utility installations are technically suitable for use as backfill in the utility trenches provided their moisture contents allow adequate compaction, especially the sand with little /some silt and clay. If the work is performed during the wet season, the soils containing silt and clay will be difficult to compact due to their high moisture content, and construction delays may result from their use. Consideration should be given to using select clean backfiil in the utility trenches if the soils have high fines contents (silt and clay) and are saturated. 60 Flexible Pavement Sections Traffic Group Structural Number Thickness (inches) Stabilized Subgrade Base Course Surface Course Light duty 2.7 12 6 1.5 Light duty (Optional) 2.7 -- 12 1.5 Heavy duty 3.3 12 8 2 Heavy duty (Optional) 3.3 -- 14 2 The stabilized subgrade should have a minimum LBR value of 40, and should be compacted to at least 98% of the modified Proctor maximum dry density (AASHTO T -180). The base course should be free draining FDOT approved limerock or coquina (or equivalent) with a minimum LBR value of 100. The base course should be placed in lifts not to exceed 6 inches, and compacted to at least 98% of the modified Proctor maximum dry density (AASHTO T- 180). The surface course should be designed and tested in accordance with the current FDOT specifications. Utility Installation Dewatering will be required for the installation of some of the underground utilities. In the locations that were explored, the excavated soils from the utility installations are technically suitable for use as backfill in the utility trenches provided their moisture contents allow adequate compaction, especially the sand with little /some silt and clay. If the work is performed during the wet season, the soils containing silt and clay will be difficult to compact due to their high moisture content, and construction delays may result from their use. Consideration should be given to using select clean backfiil in the utility trenches if the soils have high fines contents (silt and clay) and are saturated. 60 Geotechnical Services for Stormwater Management Planning 704 N Parrott Okeechobee, Okeechobee County, Florida GFA Project No. 12- 2292.00 December 11, 2012 Page 6 Curbing Curbing used around the landscaped sections adjacent to the parking Tots and access drives should be constructed with full -depth curb sections. Using extruded curb sections which lie directly on top of the final asphalt level, or eliminating the curbing entirely, can allow runoff and irrigation water (from the landscape areas) to seep between the asphalt and the base causing a separation of the wearing surface, subsequent rippling and early pavement deterioration. SITE PREPARATION RECOMMENDATIONS - PAVEMENT Stripping, Proofrolling and Proofcompaction The proposed pavement areas should be stripped of all surface vegetation, trees, roots, debris and other deleterious matter within and at least 5 feet beyond the perimeter of the proposed pavement areas. Any areas to receive fill should be likewise stripped. Foundations and any below grade remains of any structures that were previously within the footprint of the proposed construction should be removed. Existing utilities should be located, properly capped at the property line and removed or rerouted around the footprint of the proposed construction. Septic tank remains and septic fields within the footprint of the proposed construction should be removed and the excavation backfilled with compacted lifts of suitable soil. Trees within the footprint of the proposed construction will have to be removed and the tree holes should be backfilled with compacted soil. The areas should be proofrolled and compacted with a 5 to 10 -ton vibratory (or static if vibration is of concern) roller operating at a "slow walk" speed. The roller should make at least 6 overlapping passes over the entire cleared area, 3 passes in one direction and 3 more at a right angle to the first 3 passes. Proofrolling helps to detect any soft or loose zones and buried debris. If unstable areas are encountered, the project engineer or the geotechnical consultant should be advised, the matter investigated and the problem resolved. Because the initial proofrolling is very critical, we recommend that a representative of GFA monitor the operation. After proofrolling, the cleared areas should be compacted until the upper 2 feet of soil achieve a density of at least 98% of the modified Proctor maximum dry density (AASHTO T- 180). A representative of GFA should check the compaction with field density tests prior to placing any fill. A vibratory roller may be used for proofrolling, stripped surface and fill compaction if existing structure(s) are of sufficient distance (generally 40 feet) away from the vibratory roller so that the structure(s) are not damaged by vibrations. If not, the proofrolling and compaction should be performed with static rolling (vibratory mode 'off). Prior to beginning compaction operations, photographs of nearby structures can be taken to document the condition and visible cracking for claim purposes. Alternative equipment, such as front -end loaders with Grh Geotechnical Services for Stormwater Management Planning 704 N Parrott Okeechobee, Okeechobee County, Florida GFA Project No. 12- 2292.00 December 11, 2012 Page 7 buckets filled with soil, has been used successfully to attain the required compaction without the problem of vibration. Earthwork Recommendations Fill should be "clean" sand with less than 5% fines (percent of dry weight passing a U.S. No. 200 sieve). Higher fine contents can be used but more construction control is necessary. Hand operated equipment should be used when in close proximity to walls or other structures that could be adversely affected by vibrations or heavy equipment. The fill should be placed in 12 -inch thick compacted lifts with each lift compacted to at least 98% of the modified Proctor maximum dry density (AASHTO T -180). The compaction should be checked with field density tests. Vibration Monitoring Using vibratory compaction equipment at this site may disturb adjacent structures (generally structures within 40 feet of roller could be affected). Nearby structures should be monitored before and during proof - compaction. If disturbances are noted, the vibratory compaction should be halted immediately, and GFA should be advised. We will review the construction progress, and evaluate if the subgrade has attained satisfactory compaction in compliance with our design assumptions. Altemative equipment, such as front -end loaders with buckets filled with soil, has been used successfully to attain the required compaction. Prior to beginning compaction operations, photographs of nearby structures can be taken to document the condition and visible cracking for claim purposes. CLOSURE This consulting report has been prepared for the exclusive use of the current project owners and other members of the design team for the project. This report has been prepared in accordance with generally accepted local geotechnical engineering practices; no other warranty is expressed or implied. The evaluation submitted in this report, is based in part upon the data collected during a field exploration, however, the nature and extent of variations throughout the subsurface profile may not become evident until the time of construction. If variations then appear evident, it may be necessary to reevaluate information and professional opinions as provided in this report. In the event changes are made in the nature, design, or locations of the proposed structure, the evaluation and opinions contained in this report shall not be considered valid, unless the changes are reviewed and conclusions modified or verified in writing by GFA International. The analysis and recommendations submitted in this report are based on the data obtained from the tests performed. This report does not reflect any variations, which may occur between borings. While the borings are representative of the subsurface conditions at their respective locations and for their vertical reaches, local variations characteristic of the subsurface soils of the region are anticipated and may be encountered. The delineation GV Geotechnical Services for Stormwater Management Planning 704 N Parrott Okeechobee, Okeechobee County, Florida GFA Project No. 12- 2292.00 December 11, 2012 Page 8 between soil types shown on the soil logs is approximate and the description represents our interpretation of the subsurface conditions at the designated boring locations on the particular date drilled. Any third party reliance of our geotechnical report or parts thereof is strictly prohibited without the expressed written consent of GFA International. Any third party reliance of our geotechnical report or parts thereof is strictly prohibited without the expressed written consent of GFA International. The applicable SPT methodology (ASTM D- 1586), CPT methodology (ASTM D- 3441), and Auger Boring methodology (ASMT D -1452) used in performing our borings /soundings and for determining penetration resistance is specific to the sampling tools utilized and does not reflect the ease or difficulty to advance other tools, equipment or materials. We appreciate the opportunity to be of service to you on this project and look forward to a continued association with Steven L. Dobbs Engineering, LLC. Please contact the undersigned if you have any questions or comments, or if we may further assist you as your plans proceed. Respectfully Submitted, GFA IN, AL, INC. FBI: ,, aoatlg41p30 7( OF Niftier, P.E * diitecNical , �'' eer Fro RitSts4tiorr :$60675 '',,10A/A i iEINI ' o``• Attachments: Boring Location Plan Auger Boring Logs (3) Exfiltration Test Report (1) Key to Soil Classification Copies: Client (2) vid Alker Project Manager 11FTP/ERCE \Stuart- Files1Projects12012112- 2292.00 - 2012 -041 Bartels, Okeechobee (Steven L. Dobbs Engineering)VGeo112- 2292.00 - Stormwater Report. doc 60 1 BORING LOCATION PLAN Geotechnical Services for Stormwater Management Planning 704 N Parrott Ave Okeechobee, Okeechobee County, Florida DATE: DECEMBER 3, 2012 GFA PROJECT NO: 12-2292.00 GFA INTERNATIONAL 521 NW ENTERPRISE PORT ST. LUCIE, FLORIDA 34986 TEL: (772) 924-3575 FAX: (772) 924-3580 Florida's ading Engineering Source AUGER BORING LOGS WITH HAND CONE PENETROMETER (HCP) TESTS Client: Steven L. Dobbs Engineering, LLC Project: 704 N Parrott Avenue Okeechobee, Okeechobee County, Florida Elevation: Existing Grade Project No: 12- 2292.00 Lab No: Test Date: 12/3/2012 Technician: JC TEST LOCATION: AB —1 N27.25020° W80.82963° HCP Depth (feet) Description (color, texture, consistency, remarks) Depth Reading 0 - 1 Gray fine sand, trace rock pieces (A -3) (SP) 1 70 1 - 31/2 Gray to light gray fine sand (A -3) (SP) 2 80+ 31/2 - 4 Dark brown organically stained fine sand, little silt (A- 3,A -2-4) (SP -SM) 3 70 4 - 6 Brown fine sand, trace slit (A -3) (SP) 4 65 4'/2 - 6 Brown fine sand, trace silt (A -3) (SP) 5 40 6 40 Water table at 5% feet below ground surface TEST LOCATION: AB — 2 N27.25016° W80.82932° HCP Depth (feet) Description (color, texture, consistency, remarks) Depth Reading 0 -' /2 Gray fine sand, trace rock pieces (A -3) (SP) 1 60 1/2 -1 Gray fine sand (A -3) (SP) 2 70 1 - 3'/2 Light gray fine sand (A -3) (SP) 3 25 31/2 - 4% Dark brown organically stained fine sand, little silt (weakly cemented hardpan) (A- 3,A -2-4) (SP -SM) 4 65 4'/2 - 6 Brown fine sand, trace silt (A -3) (SP) 5 60 6 55 Water table at 6 feet below ground surface TEST LOCATION: AB — 3 N27.25055° W80.82931° (Top of boring elevation about 10" below AB -1 & AB -2) HCP Depth (feet) Description (color, texture, consistency, remarks) Depth Reading 0 - 31/2 Gray fine sand (A -3) (SP) 1 70 3Y2 - 4 Dark brown organically stained fine sand, little silt (A -2 -4) (SP -SM) 2 80+ 4 - 6 Brown fine sand, trace silt (A -3) (SP) 3 70 4 65 5 40 6 40 Water table at 5 feet below ground surface IIFTPI ERCEIStuart- FileslProjects12012112- 2292.00 - 2012 -041 Bartels, Okeechobee (Steven L. Dobbs Engineering)1Geo112- 2292.00 - AB w HCP (3).doc Florida Leading Engineering .Soni'l'e EXFILTRATION TEST South Florida Water Management District - Usual Open Hole Test Client: Site: Steven L. Dobbs Engineering, LLC 1062 Jakes Way Okeechobee, Florida 34974 704 N Parrott Avenue Okeechobee, Okeechobee County, Florida SOIL PROFILE Project No: Report No: Test Date: Technicians: 12- 2292.00 12/2/2012 J. Cristales Test EX -1 Location: (see Boring Location Plan) N27.25020° W80.82963° Depth Soil Description (feet) 0 -1 Gray fine sand, trace rock pieces (A -3) (SP) 1 - 3'/2 , Gray to light gray fine sand (A -3) (SP) 3 %2 - 4 Dk brown organically stained fine sand, little silt (A- 3,A- 2- 4)(SP -SM) 4 - 6 , Brown fine sand, trace silt (A- 3)(SP) Depth to Water Table from Ground Surface (feet) 53/ CALCULATION OF HYDRAULIC CONDUCTIVITY 1Ground Surface Water level for test v H2 Water Table t K= = i d 4Q nd(2H22 + 4H2Ds + H2d) Distribution: Client - 2 DWM/em K Hydraulic Conductivity (cfs/ ft2 - ft head) Stabilized Flow Rate T(cubic ft per second) i Diameter of Test Hole _j(feet) H2 ' Depth to Water Table . (feet) Ds Saturated Hole Depth (feet) 1.84 x 10414 3.57 x 1043 0.33 5.8 0.2 owiliiif it', ,`o ,.t 2r'. :s t;''� Revii*tel b d Z QRAiN - N A: O •z� D: , '+�o4er, P*,,E loric3Q,l 448trati Sn Ktev 0675 IFTPIERCE Stuart -Files Projects 2012 12- 2292.00 - 2012 -041 Bartels, Okeechobee (Steven L. Dobbs Engineering) Geo 12- 2292.00 - Exfitration Test.doc KEY TO SOIL CLASSIFICATION AMOUNT OF CONSTITUENTS IN SOIL* CLASSIFICATION OF SOIL CONSTITUENTS BY PARTICLE SIZE (ASTM D 2487 and 2488) Category Content of Minor Soil Constituents Particle Diameter Silt and Clay < 5% Soil passing a No. 200 (75 -gm) sieve Fine — Particles of rock passing the No. 40 (425 -µm) sieve and retained on the No. 200 (75 -µm) sieve Medium — Particles of rock passing the No. 10 (2.00 -mm) sieve and retained on the No. 40 (425 -µm) sieve Coarse — Particles of rock passing the No. 4 (4.75 -mm) sieve and retained on the No. 10 (2.00 -mm) sieve Sand 5% to 12% Gravel 12% to 30% Fine — Particles of rock passing the 3A -in. (19 -mm) sieve and retained on the No. 4 (4.75 -mm) sieve Coarse — Particles of rock passing the 3 -in. (75 -mm) sieve and retained on the 3A -in. (19 -mm) sieve Cobbles 30% to 50% Particles of rock passing 12 -in. square opening and retained on a 3 -in. (75 -mm) sieve Boulders _ Particles of rock that will not pass a 12 -in. square opening AMOUNT OF CONSTITUENTS IN SOIL* COARSE AND FINE GRAINED SOILS (Sand, Gravel, Silt, Clay, Shell Fragments, etc.) ORGANIC SOILS: Soils containing vegetable tissue in various stages of decomposition that has a fibrous to amorphous texture, usually a dark brown to black color, and an organic odor. Content of Minor Soil Constituents Modifier Organic Content Modifier < 5% Trace <25% Slightly to Highly Organic 5% to 12% Little 12% to 30% Some 25% to 75% Muck 30% to 50% And >75% Peat *Approximations based on visual examination of samples and results of available laboratory testing. In general accordance with test methods ASTM D 2487 and ASTM D 2488. CORRELATION OF RELATIVE DENSITY AND CONSISTENCY: SPT BORING (ASTM D 1586), CPT SOUNDING (ASTM D 3441), AND HCP TEST Granular Soils (Sands and Gravels > 50 %) Cohesive Soils (Silts and Clays >50 %) SPT N- Value* CPT Cone Bearing Value ** HCP Cone Bearing Value * ** Relative Soil Density SPT N- Value* CPT Cone Bearing Value ** HCP Cone Bearing Value * ** Relative Soil Density 0 -4 0 -20 0 -20 Very loose <2 0 -3 0 -20 Very soft 5 — 10 21 — 40 20 — 35 Loose 2 — 4 4 — 6 20 — 35 Soft 11 — 30 41 — 120 35+ Medium Dense 4 8 7 — 12 35+ Firm 31 — 50 121— 200 Dense 8 — 15 13 — 25 Stiff 50+ 200+ Very Den 15 — 30 25 — 50 Very stiff > 30 Over 50 Hard * Standard Penetration Test (SPT) N -Value Blow Counts for 12 inches. ** Cone Penetrometer Test (CPT) Cone Tip Resistance Values (in tsf). * ** Hand Cone Penetrometer Test (HCP) Cone Tip Resistance (in ksf), may not be applicable for some cohesive soils. W N THE CO TEO HER AS AN STRU NT OF TEND JOB No.:2012 -241 SHEET 1 OF 1 CRCO PROPERTIES, LLC City of Okeechobee, Florida )4. - $ . - ,y A' Ili 1r aM 1/ —E— __ srwrw A11= rw.ron 41w16 i ell gal YY ;;Tei wa k a9 L 2 a a ., as `a ESa _ I a C 1 I � ,LD I 1'4:1 DESIGNED BY: sLD I I, 3 19U97 DHEDREDBY CHECKED sLo ALTERNATE PARKING EXHIBIT g . J Q $ ti : i ..1 ,l . — �� NORZ. SCALE =60' al iY VERT. SCALE WA Prin. Dee: NO. DATE BY REVISIONS CARD FILE. 201zn02 5055 O 0 m 0 n 0 z I i 1I ill 9 +_ m 'a ■ F (..t 1 r-, . W N THE CO TEO HER AS AN STRU NT OF TEND JOB No.:2012 -241 SHEET 1 OF 1 CRCO PROPERTIES, LLC City of Okeechobee, Florida SCALE VERIFICATIONW„BY, DATE: 6 -74012 Steven L. Dobbs Engineering, LLC 1062 JAKES WAY Okeechobee, Fl 34974 Phone: (863) 824-7644 FLORIDA CERTIFICATE OF AUTHORIZATION No. 00029206 ,LD DESIGNED BY: sLD ° ■' SOLID BAR IS EQUAL TO ONE INCH ON ORIGINAL DRAWING. ADJUST ALL SCALED DIMENSIONS ACCORDINGLY DHEDREDBY CHECKED sLo ALTERNATE PARKING EXHIBIT PROJECT No.: 2012 -241 NORZ. SCALE =60' VERT. SCALE WA Prin. Dee: NO. DATE BY REVISIONS CARD FILE. 201zn02 5055 LY FOR THE SPECIFIC PURPOSE AND CLIENT FOR WHICN IT WAS PREPARED. ABUSE OP .0 IMPROPER RELIANCE ON THIS DOCUMENT WITHOUT WANT. AUTHORIZATION AND ADOPTION •Y STEVEN L. 00.3. P. L. SHALL BE wrrnour LIABILITY TO STEVEN L. GORES ENGINEERING LLC. ACCESS AGREEMENT THIS ACCESS AGREEMENT is made as of this 3rd day of April, 2013, between Glzco P.op+,.M c,, /BLec. , a Florida limited liability company, having an office at ( "A "); and fG, ,/1 c„ f-f, s�.. , a Florida limited liability company, having an office at ( "B "). Access Easements. "B" (the grantor Owner being sometimes referred to herein as the "Granting Owner ") hereby grant and convey, for the benefit of the "A's" Parcel, a non - exclusive easement and right to the use the portionlof the City of Okeechobee's Alley on "B's" Property located on the Parcel of the granting Owner, for purpose of passage by pedestrians. WITNESSES: Print Name: Print Name: Print Name: Print Name: n.40- k)k,,koP`t_ A: G1c_c.cc7 / G-- 2 "A ", a Florida limited liability company By: <112fiZ:' Dr. Charles Bartels as its Managing Member B: -0, (lS -k✓p14 S e "B ", a Florida limited liability company Anita Nunez • as its Managin: ember Anita, Please find attached an agreement between our two properties to allow pedestrian traffic through the City Alley on your property. In exchange for your agreement with this Access Easement, I will construct a concrete flume into my drainage system to drain a portion of your parking lot. - If you have any questions or require additional information, please contact me at (863)- 697 -2271 LICENSE AGREEMENT FILE NUM 2004007601 UR BK 00:29 PG 1486 SHARON ROBERTSON? CLERK, OF CIRCUIT COURT OKEECHOBEE COUNTY? FL RECORDED 04/26/2004 01:15:31 FM RECORDING FEES 10.50 RECORDED BY R O'Neill THIS AGREEMENT, BY AND BETWEEN THE CITY OF OKEECHOBEE, FLORIDA, a Florida Municipal corporation (hereinafter "CITY "), D & A SOD LANDSCAPING INC. (hereinafter "OWNER(S) "), dated this 21' day of April , 2004. WHEREAS, OWNER (S) hold fee simple title to the following described real property in Okeechobee County, Florida, to wit: Lots 3, 4, and 5 Block 77, CITY OF OKEECHOBEE, Public Records of Okeechobee County, Florida; and WHEREAS, the OWNER(S) desire to make certain improvements in the form of paving or concreting and maintaining only the Northern fifteen by one hundred forty feet (15'x140') of the alleyway located between the Lots 4 and 5, and Lot 3 of said Block 77, and installation of parking lot striping, located, within the right -of -way and alley as described which is an open, unimproved right -of -way. Which right -of -way is own ed by the CITY. NOW, THEREFORE, in consideration of the mutual promises and covenants set forth herein, the parties agree as follows: 1. The CITY hereby grants this revocable license for use of the right -of -way with the understanding the OWNER(S) will maintain the right -of -way and should it ever become necessary to remove a fence, paving, concrete, structure or any improvement thereon, in order to allow either the installation, or maintenance of water, sewer, or other utility lines or any other type of installation or construction, or for any other reason chosen by the CITY, the fence, or any improvement thereon, will be removed by the OWNER(S) or their agents and /or assigns at the OWNER(S) expense within seven days of receipt of written request by the CITY for such removal. Should the CITY, for valid reasons, require the removal of the fence, or any improvements thereon less than seven days notice, the OWNER agrees to exercise reasonable efforts to comply with such requests. 2. OWNER(S) agree to contact their insurance company and require a rider be added to their insurance policy with a certificate furnished to the CITY showing the portion of the alleyway as herein described, to be used by them, insures the CITY against any liability arising out of alleged injuries or other activities which may occur within the right -of -way. In any event, OWNER(S) agree and shall hold the CITY harmless for any and all action, suit, claim, injury or cause of action of any nature arising out of owner's permissive use, and indemnify CITY for such, including costs and attorney fees. 3. That OWNER(S) shall not, by such improvements made to that described alley, obstruct, close or otherwise restrict access to the alley for travel thereon by the CITY or the general public. 4. That the OWNER(S) agree that this license is non - assignable without the express written consent of the CITY; and if transferred, the covenants herein shall bind themselves, their heirs and assigns, and said covenants shall run with the land. 5. The City Clerk shall cause this agreement to be recorded in the public records of Okeechobee County, Florida. IN WITNESS WHEREOF, the parties hereto set their hands and seals on the aforesaid date. Page 1 of 2 Signed, sealed and delivered in presence of: Witness Print Name! %„ (Inulile4 Address: /33»i✓E r /11-. z Witness Print Na e: ' /htc%y/rlfy Address: /337/ /1/. £ tfai4G -c . ted for the City: Donnie Robertson, Public Works Director Reviewed for Legal Sufficiency: John R. Cook, City ttorney OR ELK 000529 PG 1487 David Nunez, Own D & A Sod Land ng, Inc. Anita Nunez, Owner D & A Sod Landscaping, Inc. Page 2 of 2 0,109 JanAIN4:0"),, Lane amiotea;'Gity Clerk Okeechobee County Property Appraiser - Map Printed on 4/8/2013 4:24:52... Page 1 of 1 N Itt AMI-1 S 11 15 14$.i .:_1:7:—j'_35.0(.11 -00770.4ii3i) • ' 4 GIRLS ENTERPRISES INC wow '.1.4 7 6AC I' 1 y: _g)4'4 - $120 'l(ii' - 1 1.1 r 1A 142.i 4'7'5 47.5:; 1 5o O4* iA 142 :5 47.5 NE 5TH ST 142.5 47,`.5 142.E "4" } '5) Ukt,,achy ee (..,, aunty Prot 1r " pp _41S 2 7 $22.4122 PARCEL: 3- 15- 37 -35- 0010 - 00770 -0030 - STORES /1 S (001100) CITY OF OKEECHOBEE LOTS 3, 4 & 5 BLOCK 77 Name:4 GIRLS ENTERPRISES INC LandVal $79,822.00 Site: 610 N PARROTT AVE, OKEECHOBEE BldgVal $171,167.00 Mail: 701 NE 3RD ST ApprVal $277,418.00 OKEECHOBEE, FL 34972 JustVal $277,418.00 Sales Assd $277,418.00 Info Exmpt $0.00 Taxable $277,418.00 i i t 76 152 228 fit This information, CAMA updated: 4/4/2013, was derived from data which was compiled by the Okeechobee County Property Appraiser's Office solely for the governmental purpose of property assessment. This information should not be relied upon by anyone as a determination of the ownership of property or market value. No warranties, expressed or implied, are provided for the accuracy of the data herein, it's use, or it's interpretation. Although it is periodically updated, this information may not reflect the data currently on file in the Property Appraiser's office. The assessed values are NOT certified values and therefore are subject to change before being finalized for ad valorem assessment purposes. http:// www.okeechobeepa.com /GIS/Print_ Map. asp ?pjboiibchhjbnligcafcefoc... 4/8/2013 F ( IIIII111111IllItl1111111OhIIMIIII1111111IIII112010005832 hI11I11hI1 OR B#k 00887 PG 0009 SHARON ROBERTSON, CLERK. OF CIRCUIT COURT. OKEECHOBEE COUHTYr FLORIDA RECORDED 05/28/2010 09:09:36 AM RECORDING FEES $18.50 RECORDED BY 8 Crge. h F's s 0009 - 10; (2P t s ALLEY USE LICENSE THIS LICENSE, BY AND BETWEEN THE CITY OF OKEECHOBEE, FLORIDA, a Florida Municipal corporation (hereinafter "CITY "), and Ells R. Haydon And Rita A. Koger- Haydon, (hereinafter "OWNER(S) "), dated this ; day of gay , 2010. WHEREAS, OWNER(S) hold fee simple title to the following described real property in Okeechobee County, Florida, to wit: Legal Description: Lots 18 to 20, of Block 57, City of Okeechobee, according to the plat thereof recorded in Plat Book 5, Page 5, Public Records of Okeechobee County, Florida; and WHEREAS, CITY owns the following alleyway: That 15 foot wide alleyway running North to South located between Lots 8,9,10 and 18,19, 20 of said Block 57, City of Okeechobee, according to the Plat thereof recorded in Plat Book 5, Page 5, public records of Okeechobee County, Florida; and WHEREAS, the OWNER(S) desire to make certain improvements in the form of a fence and /or gates or any improvement thereon within the alley right -of -way between Lots 8 to 10 and 18 to 20 in said Block 57, which is an open unimproved alleyway owned by the CITY. NOW, THEREFORE, in consideration of the mutual promises and covenants set forth herein, the parties agree as follows: 1. The CITY hereby grants this revocable license for use of the alleyway with the understanding the OWNER(S) will maintain the alleyway and should it ever become necessary to remove any fencing and /or gates or any improvement thereon, in order to allow either the installation, or maintenance of water, sewer, or other utility lines or any other type of installation or construction, or for any other reason chosen by the CITY, the fencing and /or gates or any improvement thereon, will be removed by the OWNER(S) or their agents and /or assigns at the OWNER(S) expense within seven days of receipt of written request by the CITY for such removal. Should the CITY, for valid reasons, require the removal of the fencing and /or gates or any improvements thereon less than seven days notice, the OWNER agrees to exercise reasonable efforts to comply with such requests. 2. OWNER(S) agree to contact their insurance company and require a rider be added to their insurance policy with a certificate furnished to the CITY showing the portion of the alleyway as herein described, to be used by them, insures the CITY against any liability arising out of alleged injuries or other activities which may occur within the alleyway. In any event, OWNER(S) agree and shall hold the CITY harmless for any and all action, suit, claim, injury or cause of action of any nature arising out of owner's permissive use, and indemnify CITY for such, including costs and attorney fees. 3. That OWNER(S) shall not, by such improvements made to that described alleyway, obstruct, close or otherwise restrict access to the alleyway for travel thereon by the CITY or the general public. 4. That the OWNER(S) agree that this license is non - assignable without the express written consent of the CITY; and if transferred, the covenants herein shall bind themselves, their heirs and assigns, and said covenants shall run with the land. Page 1 of 2 5. The City Clerk shall cause this license to be recorded in the public records of Okeechobee County, Florida. IN WITNESS WHEREOF, the parties hereto set their hands and seals on the aforesaid date. Signed, sealed and delivered in presence of: Ellis Haydon, Prope r t I P.t ,,tslAA -- -� (Witness Signature) Oi e ii'_ bomNAJL( (Witness Printed Name) 5-5 6E Aar Og.E,E ell 0IbE I rr c.._ (Witness Address) • Rita Haydon, Prope wner Witness Sig ..tturre) �i✓csA (Witness Printed Name) 311 (Witness Address) STATE OF FLOW COUNTY OF Gin n ex`Ck 6/',,k> The fo egoing instrument was . acknowledged before me this ,74 day of , 20 e , by Ellis and Rita Haydon, who signed in the presence of these witnesse ; and who produced as identification or is personally known. _ 3L1C -5 ATE OF FLORIDA Melisa M. Jahner Commission #DD908503 Expires: MAR. 09, 2013 BONGO taRU ATLANTIC BONDING CO., INC. Accepted for the City: Reviewed for Legal Suffic'ency: iZ John R. Cook, City Attorney Lc �1 l /Grkeicl Notary/Public Signature ict) /1 Jake(" Name of Notary typed, printed or stamped) Commission No. Pi) 948563 Page 2 of 2 (city seal) Lane Gamiotea, CMC, City Clerk NcT Us4I) PRELIMINARY PARTIAL DRAFT Staff Report Site Plan Review Prepared for: The City of Okeechobee Applicant: CRCO Properties, LLC (Fitness Ctr., Nutrition Store) Petition No.: 13- 002 -TRC ;e Ile, Planning & Management Services, Inc. 1375 Jackson Street; Suite 206 Fort hirers. Fkrrkcta 239- 334 -3366 Serving Florida Local Governments Since 1988 Staff Report Site Plan Review Applicant: CRCO Properties, LLC Petition No.: 13- 002 -TRC General Information Owner: Owner Address: Applicant: Applicant Address: Site Address: Contact Person Applicant/Contact Phone Number: CRCO Properties, LLC 364 NW 115th Street Okeechobee, FL 34972 CRCO Properties, LLC 364 NW 115th Street Okeechobee, FL 34972 704 North Parrott Avenue Okeechobee, FL 34972 Steven L. Dobbs, P.E., Engineer 863 - 824 -7644 Legal Description of Subject Property: Legal Description: LOTS 18, 19, AND 20, BLOCK 57, OKEECHOBEE, ACCORDING TO THE PLAT THEREOF RECORDED IN PLAT BOOK 5, PAGE 5, PUBLIC RECORDS OF OKEECHOBEE COUNTY, FLORIDA. General Description: The Applicant is converting an existing 8,000 retail furniture store to a 5,000 square foot fitness center, 1,500 square foot retail nutrition store and 1,500 square feet of warehouse space. All functions will take place inside the building with 3 — 5 employees and the hours of operation will be from 6:00 AM until 8:00 PM. Following is the Staff analysis of the project's consistency with the various City requirements and regulations. Instances where the Staff believes the submission to be deficient are highlighted. Future Land Use Map Classification Zoning District Use of Property Acreage Existing Commercial CHV Former furniture store 20,909 square feet Serving Florida Local Governments Since 1988 Proposed Commercial CHV Fitness center & Nutrition store with warehouse space 20,909 square feet 1 Staff Report Site Plan Review Applicant: CRCO Properties, LLC Petition No.: 13- 002 -TRC Adjacent FLUM Classifications, Zoning Districts, and Existing Land Use: North: Future Land Use Map Classification: Commercial Zoning District: Existing Land Use: East Future Land Use Map Classification: Commercial Zoning District: CHV Existing Land Use: Mini - storage & towing service Future Land Use Map Classification: Commercial Zoning District: CHV Quick Change oil & lube service South CHV Water testing service (& limo Existing Land Use: rentals ?) West: Future Land Use Map Classification: Commercial Zoning District: CHV Existing Land Use: Building & open storage( ?) Adequacy of Public Facilities: Due to the serious deficiencies identified relating to the provision of off - street parking, the adequacy of the site plan with respect to the adequacy of public facilities has not been evaluated at this time. Potable Water and Sanitary Sewer: Solid Waste Disposal: Traffic: Drainage: 2 Serving Florida Local Governments Since 1988 Staff Report Site Plan Review Applicant: CRCO Properties, LLC Petition No.: 13- 002 -TRC Comparison of Proposal with Dimensional Standards, CHV Zoning: Regulation Required Provided Minimum Parcel Size 6,250 square feet; 50' width 20,909 square feet; 147 ` width Minimum Front Yard Setback 20 feet for buildings, 10 feet for parking 50+ feet for building; parking is in the right -of -way Minimum Side Yard Setback 8 feet 23' east and west sides Minimum Rear Yard Setback 10 feet Existing rear setback is nonconforming at about nine feet. Maximum Lot Coverage 50% 38.6% Maximum Lot Coverage and Other Impervious Surfaces 85% 80.8% (est.) Off- street Parking @ one space 150 sf of fitness ctr (5000/150) = 33.3; 1 space per 1,000 sf of warehouse (1500/1000) = 1.5; one space per 300 sf for retail (1,500/300) = 5; total required = 40 spaces Only 37 spaces are shown. However, almost nothing about the proposed parking arrangement meets the requirements in the LDC. Most importantly 16 of the parking spaces are located in the right -of -way of NE 7th Street. There is no provi- sion in the LDC that will allow private, off - street parking to be located in the public right -of -way. Further, the 10 spaces along the east side of the building must use the public alley to gain access and require backing out onto the alley to exit the site. Even if the alley were an acceptable access way the area of the parking spaces and driveway must be 44 feet to provide the 20 -foot depth of the parking space and 24- footwidth for the driveway serving 90- degree parking. The total width available is only 39 feet. Off - street Loading One required for 5,000 to 25,000 square feet of commercial floor space. None provided. ti „ 4 Serving Florida Local Governments Since 1988 3 Staff Report Site Plan Review Applicant: CRCO Properties, LLC Petition No.: 13- 002 -TRC Regulation Required Provided Minimum Driveway Width 24 -feet for 90 degree parking Even if the alley were acceptable as a driveway location, the driveway width would only be 19 feet. Landscaping Due to the major deficien- cies identified in the proposed method of providing required off - street parking, the adequacy of the site plan with respect to land - scaping, public facilities, sidewalks, lighting plan, and dumpster location have not been addressed at this time. Nonresidential Parking Area [(Sec. 90 -533 (1) & (2)] Nonresidential Parking Area [(Sec. 90 -533 (4)] Nonresidential Parking Area [(Sec. 90 -533 (6)] Nonresidential Buffer (Sec. 90 -535) Nonresidential Lot (Sec. 90 -533) Maximum Height 45 feet Other Requirements and Considerations: Sidewalks: Lighting Plan: Dumpster Location: Recommendation: Since we find no provisions in the LDC that can be used to justify or otherwise provide a basis for approval for the of the parking arrangement as proposed by the Applicant, Staff will strongly recommend disapproval of the site plan in its current form. Submitted by: Wm. F. Brisson, AICP Planning Consultant January 24, 2013 TRC Hearing date: February 14, 2013 4 Serving Florida Local Governments Since 1988 Staff Report Site Plan Review Prepared for: The City of Okeechobee Applicant: CRCO Properties, LLC (Fitness Ctr., Nutrition Store) Petition No.: 13- 002 -TRC Planning & Management Services, Inc. 1375 Jackson Street, Suite 206 Fort Myers, Florida. 239 -334 -3366 Serving Florida Local Governments Since 1988 Staff Report Site Plan Review Applicant: CRCO Properties, LLC Petition No.: 13- 002 -TRC General Information caner' ress: ess • CRCO Properties`LI 364 NW 115th Street Okeec Sr tee Okeechobee, FL 34972 Co ntact Person Applicant/Contact Phone eechobee EL 34972 Steven L. Dobbs umber: 863 -824- 7644 nc inee Legal Description of Subject Property: Legal Description: LOTS 18, 19, AND 20, BLOCK 57, OKEECHOBEE, ACCORDING TO THE PLAT THEREOF RECORDED IN PLAT BOOK 5, PAGE 5, PUBLIC RECORDS OF OKEECHOBEE COUNTY, FLORIDA. General Description: The Applicant is converting an existing 8,000 retail furniture store to a 5,000 square foot fitness center, 1,500 square foot retail nutrition store and 1,500 square feet of warehouse space. All functions will take place inside the building with 3 — 5 employees and the hours of operation will be from 6:00 AM until 8:00 PM. Following is the Staff analysis of the project's consistency with the various City requirements and regulations. Instances where the Staff believes the submission to be deficient are highlighted. Future Land Use Map Classificatio Zoning District Use of Property Former furnitu16 or Acreage 20,909 square feet LaRue fitness cen er " "nutrition store with warehouse space 20,909 square feet Serving Florida Local Governments Since 1988 1 Staff Report Site Plan Review Applicant: CRCO Properties, LLC Petition No.: 13- 002 -TRC Adjacent FLUM Classifications, Zoning Districts, and Existing Land Use: MEE u tire Land Use Map Classification; MEW `Zoning Distri 111111111111 Existirg Land Uie; East Future Land Use Map Classification: Zoning District: Existing Land Use: uture Land Us Future Land Use Maps Zoning District: Existing Land Use: Commercia CH. Quick Chan Commercial CHV Mini - storage & towing service,.; Commerc CHV Water tes rentals ?) Commercial CHV Building & open storage( ?) Adequacy of Public Facilities: Potable Water and Sanitary Sewer: Since the demand for potable water and sewer service associated with a 5,000 square foot fitness center and other uses proposed for the existing building will significantly exceed that which would normally be associated with a furniture store, the Applicant should obtain a letter from the Okeechobee Utility Authority (OUA) stating that it has adequate capacity to serve the proposed use. Solid Waste Disposal: On a number of occasions the County has confirmed a consi- derable level of excess capacity available to serve the solid waste disposal needs of other developments in the City. It appears reasonable that the volume of solid waste associated with a development of this size can also be accommodated within the capacity of the County's Solid Waste Facility. Traffic: According to the 7th Edition, ITE Trip Generation Manual, the proposed mix of uses is likely to generate about 28 vehicle trips during the weekday PM peak hour. While this is considerably more than the most recent use as a furniture store (slightly less than four trips), it is not significant with respect to the available capacity of the adjacent roadways. I.aitue Serving Florida Local Governments Since 1988 O 2 Staff Report Site Plan Review Applicant: CRCO Properties, LLC Petition No.: 13- 002 -TRC Drainage: In the event of any increase in the amount of impervious surface on the site will require that the Applicant meet all standards required by the City of Okeechobee and the South Florida Water Management District. Comparison of Proposal with Dimensional Standards, CHV Zoning: Regulation Required Provided Minimum Parcel Size 6,250 square feet; 50' width 20,909 square feet; 147 ' width Minimum Front Yard Setback 20 feet for buildings, 10 feet for parking 50+ feet for building; par kirlg 'as ltthe -rngh#= ofLwa Minimum Side Yard Setback 8 feet 23' east and west sides Minimum Rear Yard Setback 10 feet Existing rear setback is nonconforming at about nine feet. Maximum Lot Coverage 50% 38.6% Maximum Lot Coverage and Other Impervious Surfaces 85% 80.8% (est.) Off- street Parking @ one space 150 sf of fitness ctr (5000/150) = 33.3; 1 space per 1,000 sf of warehouse (1500/1000) = 1.5; one space per 300 sf for retail (1,500/300) = 5; total required = 40 spaces Only 37 spaces are shown. However, almost nothing about the proposed parking arrangement meets the requirements in the LDC. Most importantly 16 of the parking spaces are located in the right -of -way of NE 7u' Street. There is no provision in the LDC,that allows private, off - street parking to be located m the publght -of v ✓ay : ic ri Further, the 10 spaces along the east side d' the building must use the public alley to gain access and require backing out onto the alley to exit the site. Even if the alley were an acceptable accessway, the area of the parking spaces and driveway must be 44 feet to provide the 20 -foot depth of the parking space and 24- footwidth for the driveway serving 90- degree parking. The total width available is only 39 feet. Serving Florida Local Governments Since 1988 3 Staff Report Site Plan Review Applicant: CRCO Properties, LLC Petition No.: 13- 002 -TRC DISCUSSION REGARDING USE OF REMOTE PARKING BEHIND BIG LAKE EYECARE The Applicant has suggested using the unimproved area behind Big Lake Eye Care, a property also owned by the Applicant to augment the nine spaces presently located on the subject site. Staff has visited the site and nearby properties and explored the viability of using this property as a remote parking lot to serve the proposed use under the provisions of §90- 511(a)(2). This visit indicated that the only convenient and likely pedestrian route to be utilized by patrons of the proposed use(s) to go to and from the proposed off -site parking area would be crossing NW 7th Street into and through the parking lot behind the property located at 610 N. Parrott Avenue. Since this property is not owned by the Applicant, we believe it would be necessary to obtain a written agreement with the owner of 610 N. Parrott Avenue to allow pedestrian and /or vehicular access across this private property to access the remote parking area behind Big Lake Eye Care. Without such an agreement, safe and convenient access to the remote lot could not be guaranteed and therefore the remote lot could not be considered to adequately serve the proposed use, as required under §90- 511(a)(2). Should the Applicant obtain the needed permission to allow wither pedestrian or vehicular access through the 610 N. Parrott property, the Applicant will need to construct a new paved parking area that meets City standards and provides the complement of parking spaces that, together with those spaces on the subject property will meet the minimum number of off - street parking spaces required of the uses by the LDC. Off - street Loading One required for 5,000 to 25,000 square feet of commercial floor space. None provided; Minimum Driveway Width 24 -feet for 90 degree parking E�enrf the alley °was acceptable as 'a driveway location, the driveway width ould only be 19 feet. Landscaping Requirements for parking and vehicular use areas (Sec. 90 -533) As ®: _ ,...� > ®,, ad:'► feria ° par iri s p g provided on site, and no other physical changes are made to the subject site the property can be considered grandfathered with respect to the need for landscaping and buffering. However, the Applicant will ultimately need to submit a landscape plan for the remote parking lot that meets all of the applicable landscape requirements. Required landscape buffer areas (Sec. 90 -534) Landscape design and plan. (Sec. 90 -538) Serving Florida Local Governments Since 1988 4 Staff Report Site Plan Review Applicant: CRCO Properties, LLC Petition No.: 13- 002 -TRC Other Requirements and Considerations: Sidewalks: There are no sidewalks anywhere along the north side of NE 7th Street. There is a sidewalk along the south side of the street for between Parrott Avenue and NE 3rd Avenue. Lighting Plan: If Iig Dumpster Location: find accep a e to serve tne proposed use(s), a o „dumpster, oc tion indicated on the site plan. Recommendation: Since we find no provisions in the LDC that can be used to justify or otherwise provide a basis for approval of the parking arrangement as shown on the site plan, Staff disapproval of the site plan in its current form. strongly recommends The only alternative we see would be if the TRC should find that suitable arrangements have been made by the Applicant to ensure a safe and convenient pedestrian route from a remote location to the proposed use(s) that does not require the unauthorized use of other private property, the TRC meeting be continued until such time as the Applicant provides documen- tation of such an arrangement, and a revised site plan is submitted addressing all of the deficiencies identified in this Staff Report and any other stipulations required by the TRC. Submitted by: Wm. F. Brisson, AICP Planning Consultant March 14, 2013 TRC Hearing date: March 21, 2013 Serving Florida Local Governments Since 1988 5